| Literature DB >> 27293878 |
Lie Horiguchi1, Patricia Novita Garcia2, Gustavo Ricci Malavazzi2, Norma Allemann3, Rachel L R Gomes4.
Abstract
Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL) using ultrasound biomicroscopy (UBM). Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6%) and the ab interno in 8 eyes (53.3%). In the ab externo technique, 14 haptics were located: 4 (28.57%) in the ciliary sulcus; 2 (14.28%) anterior to the sulcus; and 8 (57.14%) posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0%) were in the ciliary sulcus, 2 (12.50%) anterior to the sulcus, and 10 (75.0%) posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno.Entities:
Year: 2016 PMID: 27293878 PMCID: PMC4887626 DOI: 10.1155/2016/9375091
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Demographics of the sample and cause and technique used for intraocular lens fixation and postoperative IOL positioning evaluated using ultrasound biomicroscopy.
| Age (yrs) | Gender | Cause of inadequate capsular support | IOL fixation surgical technique | Postoperative UBM haptics position in relation to sulcus |
|---|---|---|---|---|
| 77 | F | After Phaco aphakia |
| (1) Posterior-pars plana |
| 80 | M | Decentered IOL |
| (1) Posterior-pars plana |
| 58 | M | Unknown aphakia |
| (1) Posterior-ciliary body |
| 55 | F | After Phaco aphakia |
| (1) Posterior-pars plana |
| 82 | F | After ICE aphakia |
| (1) Posterior-ciliary body |
| 73 | F | After Phaco aphakia |
| (1) Posterior-pars plana |
| 60 | F | After Phaco aphakia |
| (1) Posterior-pars plana |
| 63 | M | Subluxated cataract |
| (1) Sulcus |
| 18 | M | Subluxated cataract |
| (1) Posterior-ciliary body |
| 43 | F | Subluxated cataract |
| (1) Sulcus |
| 69 | M | After ECE aphakia |
| (1) Sulcus |
| 82 | F | After Phaco aphakia |
| (1) Sulcus |
| 93 | M | After Phaco aphakia |
| (1) Posterior-ciliary body |
| 72 | M | After Phaco aphakia |
| (1) Posterior-ciliary Body |
| 28 | F | Unknown aphakia |
| (1) Posterior-ciliary body |
F: female; M: male; IOL: intraocular lens; ECE: extracapsular extraction; Phaco: phacoemulsification; ICE: intracapsular extraction; (1): haptic 1; (2): haptic 2.
Figure 1Ultrasound biomicroscopy of the left eye submitted to intraocular lens fixation using ab externo technique. (a) Horizontal plane showing good lens positioning; (b) vertical tilt of the IOL, lens placed more posteriorly in the superior meridian compared to the inferior meridian.
Figure 2Ultrasound biomicroscopy of eyes submitted to intraocular lens fixation using UBM images. Arrows show the ciliary body, and arrow heads show the haptic. (a) Ab externo, haptic placed in the ciliary body; (b) ab interno, haptic in the sulcus; (c) ab interno, haptic posterior to the ciliary body; (d) haptic in the sulcus.
Intraocular lens position in relation to the iris (IOL tilt) in the horizontal plane (3 and 9 h), considering UBM findings.
|
| Mean (mm) | SD | 95% confidence interval | ||
|---|---|---|---|---|---|
| Inferior | Superior | ||||
|
| 7 | −0.12 | 0.1603 | −0.4356 | 0.927 |
|
| 8 | −0.04 | 0.1138 | −0.2668 | 0.1793 |
| Total | 15 | −0.08 | 0.0933 | −0.2628 | 0.1028 |
SD: standard deviation; IOL: intraocular lens.
Intraocular lens position in relation to the iris (IOL tilt) in the vertical plane (12 and 6 h), considering UBM findings.
|
| Mean (mm) | SD | 95% confidence interval | ||
|---|---|---|---|---|---|
| Inferior | Superior | ||||
|
| 7 | −0.36 | 0.1261 | −0.6058 | −0.1113 |
|
| 8 | −0.2 | 0.1059 | −0.4101 | 0.0051 |
| Total | 15 | −0.28 | 0.0813 | −0.4347 | −0.116 |
SD: standard deviation; IOL: intraocular lens.