Literature DB >> 20457368

Retrospective ultrasound biomicroscopic analysis of single-piece sulcus-fixated acrylic intraocular lenses.

Abhay R Vasavada1, Shetal M Raj, Shrihari Karve, Viraj Vasavada, Vaishali Vasavada, Panagiotis Theoulakis.   

Abstract

PURPOSE: To evaluate the anatomic location of the haptic and optic of single-piece sulcus-fixated intraocular lenses (IOLs) and their proximity to the iris and ciliary body using ultrasound biomicroscopy (UBM).
SETTING: Iladevi Cataract & IOL Research Center, Ahmedabad, India.
METHODS: This retrospective study comprised eyes that had primary sulcus implantation of a single-piece IOL. Eyes had an intact anterior capsulorhexis that could provide uniform IOL support and a preoperative anterior chamber depth (ACD) greater than 2.7 mm. The fixation site of the haptics, distance between the optic edge and iris, optic tilt, anterior chamber angle (ACA), central ACD, and ciliary body edema were evaluated by UBM.
RESULTS: The time from surgery to UBM examination was 7 to 85 months. Both haptics were in the sulcus in 7 of the 10 eyes, 1 haptic was abutting the iris and the other was in the sulcus in 2 eyes, and both haptics were embedded in ciliary body in 1 eye. The mean distance between the optic edge and iris was 0.16 mm +/- 0.07 (SD), 0.15 +/- 0.03 mm, and 0.38 mm, respectively. The mean ACA was 40.2 +/- 4.5 degrees (range 30.9 to 45.2 degrees), 34.1 +/- 4.5 degrees, and 44.1 degrees, respectively. The mean ACD was 3.47 +/- 0.24 mm, 3.50 +/- 0.23 mm, and 3.57 mm, respectively. No eye had optic tilt or ciliary body edema.
CONCLUSIONS: Implantation of both haptics in the sulcus was not achieved in all eyes. The haptics and optics remained in close proximity to the posterior iris surface. (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20457368     DOI: 10.1016/j.jcrs.2009.11.027

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Anterior chamber angle evaluation with ultrasound biomicroscopy and optical coherence tomography in eyes implanted with a Crystalens.

Authors:  Efstathios T Detorakis; Alexandra Karavitaki; Nela Stojanovic; George Kontadakis; Ioannis G Pallikaris
Journal:  Int Ophthalmol       Date:  2013-10-29       Impact factor: 2.031

2.  Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

Authors:  Xuhua Tan; Haotian Lin; Zhuoling Lin; Jingjing Chen; Xiangchen Tang; Lixia Luo; Weirong Chen; Yizhi Liu
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

3.  Outcome of Single-piece Intraocular Lens Sulcus Implantation following Posterior Capsular Rupture during Phacoemulsification.

Authors:  Masomeh Mohebbi; Seyed Ali Bashiri; Seyed Farzad Mohammadi; Behnaz Samet; Fariba Ghassemi; Elham Ashrafi; Fatemeh Bazvand
Journal:  J Ophthalmic Vis Res       Date:  2017 Jul-Sep

4.  In-the-bag intraocular lens placement via secondary capsulorhexis with radiofrequency diathermy in pediatric aphakic eyes.

Authors:  Lixia Luo; Haotian Lin; Weirong Chen; Chunxiao Wang; Xinyu Zhang; Xiangchen Tang; Jianping Liu; Nathan Congdon; Jingjing Chen; Zhuoling Lin; Yizhi Liu
Journal:  PLoS One       Date:  2013-04-24       Impact factor: 3.240

5.  Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation.

Authors:  Lie Horiguchi; Patricia Novita Garcia; Gustavo Ricci Malavazzi; Norma Allemann; Rachel L R Gomes
Journal:  J Ophthalmol       Date:  2016-05-18       Impact factor: 1.909

6.  Capsular Outcomes Differ with Capsulorhexis Sizes after Pediatric Cataract Surgery: A Randomized Controlled Trial.

Authors:  Haotian Lin; Xuhua Tan; Zhuoling Lin; Jingjing Chen; Lixia Luo; Xiaohang Wu; Erping Long; Weirong Chen; Yizhi Liu
Journal:  Sci Rep       Date:  2015-11-05       Impact factor: 4.379

Review 7.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.