Literature DB >> 23988241

Modified ab externo method for introducing 2 polypropylene loops for scleral suture fixation of intraocular lenses.

Masaaki Seki1, Susumu Yamamoto, Haruki Abe, Takeo Fukuchi.   

Abstract

We describe a method that enables the introduction of 2 suture loops for scleral fixation of an intraocular lens (IOL) by a single ab externo procedure. A long needle carrying a polypropylene suture loop is inserted through the scleral fixation site and docked with a hollow needle inserted through the opposite fixation site. The hollow needle pulls the suture needle out, but the suture loop end is left external. Another polypropylene suture loop is placed through the first loop. As the first (leading) suture is pulled, the second (trailing) suture is drawn into the eye. The suture loops are retrieved through the main incision. The IOL haptics are secured with a polypropylene loop by cow hitches. After the IOL is placed in the eye, the sutures are fixated to the sclera. This technique enhances efficiency and control during the introduction of suture loops for scleral fixation of IOLs.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23988241     DOI: 10.1016/j.jcrs.2013.07.003

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Scleral fixation of a posterior chamber intraocular lens combined with penetrating keratoplasty in an aphakic patient with microcornea and microphthalmia.

Authors:  He J Li; Konstantinos T Tsaousis; Geoffrey C Tabin
Journal:  BMJ Case Rep       Date:  2016-04-06

2.  Late dislocation of the capsular bag-intraocular lens-modified capsular tension ring complex after knotless transscleral suturing using 9-0 polypropylene.

Authors:  Natalia S Anisimova; Lisa B Arbisser; Natalya F Shilova; Roman V Kirtaev; Daria A Dibina; Boris E Malyugin
Journal:  Digit J Ophthalmol       Date:  2020-06-26

3.  Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

Authors:  J Lyu; P-Q Zhao
Journal:  Eye (Lond)       Date:  2016-01-22       Impact factor: 3.775

4.  Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation.

Authors:  Lie Horiguchi; Patricia Novita Garcia; Gustavo Ricci Malavazzi; Norma Allemann; Rachel L R Gomes
Journal:  J Ophthalmol       Date:  2016-05-18       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.