Quantitative analysis of multiple biokinetic models using a dynamic water phantom: A feasibility study.

Fu-Tsai Chiang1,2, Pei-Jung Li3, Shih-Ping Chung1,4, Lung-Fa Pan1,5, Lung-Kwang Pan1.   

Abstract

This study analyzed multiple biokinetic models using a dynamic water phantom. The phantom was custom-made with acrylic materials to model metabolic mechanisms in the human body. It had 4 spherical chambers of different sizes, connected by 8 ditches to form a complex and adjustable water loop. One infusion and drain pole connected the chambers to an auxiliary silicon-based hose, respectively. The radio-active compound solution (TC-99m-MDP labeled) formed a sealed and static water loop inside the phantom. As clean feed water was infused to replace the original solution, the system mimicked metabolic mechanisms for data acquisition. Five cases with different water loop settings were tested and analyzed, with case settings changed by controlling valve poles located in the ditches. The phantom could also be changed from model A to model B by transferring its vertical configuration. The phantom was surveyed with a clinical gamma camera to determine the time-dependent intensity of every chamber. The recorded counts per pixel in each chamber were analyzed and normalized to compare with theoretical estimations from the MATLAB program. Every preset case was represented by uniquely defined, time-dependent, simultaneous differential equations, and a corresponding MATLAB program optimized the solutions by comparing theoretical calculations and practical measurements. A dimensionless agreement (AT) index was recommended to evaluate the comparison in each case. ATs varied from 5.6 to 48.7 over the 5 cases, indicating that this work presented an acceptable feasibility study.

Entities:  

Keywords:  Tc-99 m; biokinetic model; dynamic phantom; multiple compartments

Mesh:

Substances:

Year:  2016        PMID: 27286096      PMCID: PMC5060983          DOI: 10.1080/21655979.2016.1197738

Source DB:  PubMed          Journal:  Bioengineered        ISSN: 2165-5979            Impact factor:   3.269


  7 in total

1.  Measurement of gastric emptying time of solids in healthy subjects using scintigraphic method: a revised technique.

Authors:  Chia Chun Hsu; Pei Yu Chen; Chang Chi Chen; Lung Kwang Pan
Journal:  Radiat Prot Dosimetry       Date:  2011-11-16       Impact factor: 0.972

2.  Characterization of attenuation and respiratory motion artifacts and their influence on SPECT MP image evaluation using a dynamic phantom assembly with variable cardiac defects.

Authors:  Isabelle Chrysanthou-Baustert; Irene Polycarpou; Ourania Demetriadou; Lefteris Livieratos; Antonis Lontos; Antonis Antoniou; Stelios Christofides; Charalambos Yiannakkaras; Demetris Kaolis; Christoforos Panagidis; Paul K Marsden; Yiannis Parpottas
Journal:  J Nucl Cardiol       Date:  2016-02-04       Impact factor: 5.952

3.  Effects of heart rate, filling and slice thickness on the accuracy of left ventricular volume measurements in a dynamic cardiac phantom using ECG-gated MDCT.

Authors:  H Doğan; W J H Veldkamp; P Dibbets-Schneider; A M Spijkerboer; B J A Mertens; L J M Kroft; A De Roos; J Geleijns
Journal:  Br J Radiol       Date:  2008-03-03       Impact factor: 3.039

4.  Externally navigated bronchoscopy using 2-D motion sensors: dynamic phantom validation.

Authors:  Xiongbiao Luo; Takayuki Kitasaka; Kensaku Mori
Journal:  IEEE Trans Med Imaging       Date:  2013-05-15       Impact factor: 10.048

5.  The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Samuel R Mazin; Edward E Graves; Paul J Keall
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

6.  Effective half life of iodine for five thyroidectomy patients using an in vivo gamma camera approach.

Authors:  Chien-Yi Chen; Pai-Jung Chang; Sheng-Pin Changlai; Lung-Kwang Pan
Journal:  J Radiat Res       Date:  2007-10-30       Impact factor: 2.724

7.  Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans.

Authors:  Joseph H Killoran; Victor H Gerbaudo; Marcelo Mamede; Dan Ionascu; Sang-June Park; Ross Berbeco
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

  7 in total
  1 in total

1.  A quantitative evaluation of multiple biokinetic models using an assembled water phantom: A feasibility study.

Authors:  Da-Ming Yeh; Ching-Yuan Chen; Jing-Fa Tang; Lung-Kwang Pan
Journal:  PLoS One       Date:  2017-12-21       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.