Literature DB >> 17971626

Effective half life of iodine for five thyroidectomy patients using an in vivo gamma camera approach.

Chien-Yi Chen1, Pai-Jung Chang, Sheng-Pin Changlai, Lung-Kwang Pan.   

Abstract

The effective half-life of radioactive iodine for (near) thyroidectomy patients was evaluated using an in vivo gamma camera approach. Five patients with post administered iodine for remnant ablation of thyroid were thoroughly scanned in vivo for one to four weeks. Derived data were analyzed in a MATLAB program to revise the ICRP recommended effective half-life and, thus, to offer a more reliable dose predication protocol from a health physics viewpoint. A quantitative index, AT (Agreement), was also introduced to specify the deviation between the actual measurement and the results fitted in MATLAB for each patient. The ATs were evaluated as 1.52 +/- 1.54 and 14.05 +/- 11.01 for the thyroid compartment and the remainder, re-spectively, indicating a slight discrepancy between the computed and practical results for the remainder. The actual effective half-life of iodine in the thyroid or the body fluid compartment shifted from 7.3d or 0.24 d to only 0.61 +/- 0.50 d or 0.49 +/- 0.23 d, respectively. Additionally, the integrated T(eff) for the remainder (both body fluid and whole body compartments) was still about 5.8d, since the body fluid and the whole body compartment was inseparable in real whole body scanning. The branching ratio from body fluid compartment to the thyroid and the excretion compartment also changed from 30% and 70% to 11.6 +/- 14.0% and 88.4 +/- 14.6%, respectively. The thyroid was the dominant compartment for a healthy person in the traditional biokinetic model. However, this dominant compartment was shifted to both thyroid and body fluid, based on analyses of the data following thyroidectomy, for the patients herein.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17971626     DOI: 10.1269/jrr.07031

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  4 in total

1.  Quantitative analysis of multiple biokinetic models using a dynamic water phantom: A feasibility study.

Authors:  Fu-Tsai Chiang; Pei-Jung Li; Shih-Ping Chung; Lung-Fa Pan; Lung-Kwang Pan
Journal:  Bioengineered       Date:  2016-06-10       Impact factor: 3.269

Review 2.  The sodium iodide symporter (NIS) as an imaging reporter for gene, viral, and cell-based therapies.

Authors:  Alan R Penheiter; Stephen J Russell; Stephanie K Carlson
Journal:  Curr Gene Ther       Date:  2012-02-01       Impact factor: 4.391

3.  A quantitative evaluation of multiple biokinetic models using an assembled water phantom: A feasibility study.

Authors:  Da-Ming Yeh; Ching-Yuan Chen; Jing-Fa Tang; Lung-Kwang Pan
Journal:  PLoS One       Date:  2017-12-21       Impact factor: 3.240

4.  TLD environmental monitoring of new scanner facilities at the Nuclear Medicine Department of the Taiwan Medical University Hospital.

Authors:  Yingyi Le; Jui-Hung Weng; Tsung-Min Lee; Yueh-Chun Lee; Pan-Fu Kao; Lung-Kwang Pan; Chien-Yi Chen
Journal:  Technol Health Care       Date:  2020       Impact factor: 1.285

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.