Effects of heart rate, filling and slice thickness on the accuracy of left ventricular volume measurements in a dynamic cardiac phantom using ECG-gated MDCT.

H Doğan1, W J H Veldkamp, P Dibbets-Schneider, A M Spijkerboer, B J A Mertens, L J M Kroft, A De Roos, J Geleijns.   

Abstract

The objective of the study was to assess the effect of heart rate, filling condition and slice thickness on the accuracy of volumetric analysis based on multidetector-row computed tomography (MDCT) of a cardiac phantom. Retrospective electrocardiogram-gated MDCT of a pulsating phantom was performed under different conditions. End-diastolic volume (EDV) and end-systolic volume (ESV) for different heart rates (60-75 beats per minute), filling volumes and reconstructed slice thicknesses (2 mm and 5 mm) were obtained by three observers. Results were analysed by a linear mixed-effects model. Significant effects on the accuracy were found for heart rate (F-value, 7.3-39.2; p<0.004) and filling condition (F-value, 7.4-55.6; p<0.004), but not for slice thickness. Small relative differences in the assessment of EDV were found (range, -3% to 3%), but there was a trend for overestimation of the ESV (range, -1% to 18%). Underestimation of stroke volume and ejection fraction (range, -1% to -11%) became smaller under conditions of improved temporal resolution and larger EDV. Good interobserver agreement was found (SD <1.8 ml and <0.5%). In conclusion, MDCT allows sufficient and reliable measurements of ventricular volumes and calculation of left ventricle function for clinical applications. Heart rate and filling conditions significantly affect the accuracy of volumetrics, as demonstrated in this cardiac phantom. Thicker slices provide similar accuracy to thin slices.

Entities:  

Mesh:

Year:  2008        PMID: 18316343     DOI: 10.1259/bjr/92798700

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Automatic vs semi-automatic global cardiac function assessment using 64-row CT.

Authors:  J Greupner; E Zimmermann; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

2.  Quantitative analysis of multiple biokinetic models using a dynamic water phantom: A feasibility study.

Authors:  Fu-Tsai Chiang; Pei-Jung Li; Shih-Ping Chung; Lung-Fa Pan; Lung-Kwang Pan
Journal:  Bioengineered       Date:  2016-06-10       Impact factor: 3.269

3.  Assessment of slice thickness effect on visibility of inferior alveolar canal in cone beam computed tomography images.

Authors:  Daryoush Goodarzi Pour; Banafsheh Arzi; Ahmad Reza Shamshiri
Journal:  Dent Res J (Isfahan)       Date:  2016 Nov-Dec

4.  Radiological and Morphometric Features of Canalis Sinuosus in Russian Population: Cone-Beam Computed Tomography Study.

Authors:  Avanesov Anatoly; Yuri Sedov; Evgeniya Gvozdikova; Oleg Mordanov; Liudmila Kruchinina; Karen Avanesov; Anna Vinogradova; Sergei Golub; Dalila Khaydar; Nguyen Giao Hoang; Hadi M Darawsheh
Journal:  Int J Dent       Date:  2019-12-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.