| Literature DB >> 27252761 |
Marzieh Alikhasi1, Hakimeh Siadat2, Elaheh Beyabanaki3, Mohammad Javad Kharazifard4.
Abstract
OBJECTIVES: The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials.Entities:
Keywords: Dental Implants; Dental Impression Materials; Dental Impression Technique
Year: 2015 PMID: 27252761 PMCID: PMC4888164
Source DB: PubMed Journal: J Dent (Tehran) ISSN: 1735-2150
Fig. 1The metal reference model (A). The schematic view of three grooves with 0.25, 0.50 and 0.75 mm depths (B).
Fig. 2The closed-tray and open-tray transfer copings.
Fig. 3Schematic drawings of the measurements of implants in x, and y directions. The red drawing indicates baseline measurements on the reference model (A). The green lines show the measurement on the cast superimposed on the original diagram (B).
Fig. 4Schematic drawings of the measurements of implants for rotational displacement on the reference model (A), and on the cast superimposed on the original diagram (B).
The absolute mean values (±SD) and comparison of the recorded measurements in the groups.
|
|
|
| ||
|---|---|---|---|---|
|
| ||||
|
|
|
|
| |
|
| ||||
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Evaluation of the effect of impression technique, material and their interaction effect on the variables of horizontal, vertical, linear and angular displacements and also line depth by two-way ANOVA
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|
|
|
<.001
| 0.240 |
<.001
|
<.001
| 0.835 | 0.584 | 0.920 |
|
|
<.001
| 0.893 |
<.001
|
<.001
| 0.424 | 0.391 | 0.065 |
|
|
<.001
|
0.001
|
<.001
|
<.001
| 0.119 | 0.654 | 0.984 |
|
|
significant effect in 0.05 level of significancy
Calculated P-values of the effect of impression technique on horizontal, vertical, linear and angular displacement variables by t- test
|
|
|
|
|---|---|---|
|
| Linear |
<0.001
|
|
| Horizontal |
<0.001
|
|
| Vertical |
0.01
|
|
| Angular | 0.16 |
|
| Linear |
<0.001
|
|
| Horizontal |
<0.001
|
|
| Vertical |
0.04
|
|
| Angular |
<0.001
|
significant effect in 0.05 level of significancy
Calculated P-values of the effect of impression material on linear and angular displacement variables by t-test.
|
|
|
|
| |
|---|---|---|---|---|
|
| Linear | Regular poly ether | Regular poly vinyl |
<0.001
|
| Angular | Regular poly ether | Regular poly vinyl |
<0.001
| |
|
| Linear | Regular poly ether | Regular poly vinyl |
<0.001
|
significant effect in 0.05 level of significancy