Literature DB >> 27236530

Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Victor Dayan1, Gustavo Vignolo2, Gerardo Soca2, Juan Jose Paganini2, Daniel Brusich2, Philippe Pibarot3.   

Abstract

OBJECTIVES: This study sought to evaluate predictors of prosthesis-patient mismatch (PPM) and its association with the risk of perioperative and overall mortality.
BACKGROUND: PPM is associated with increased mid- and long-term mortality after surgical aortic valve replacement. Conflicting results have been reported with regard to its association with perioperative mortality.
METHODS: Databases were searched for studies published between 1965 and 2014. Main outcomes of interest were perioperative mortality and overall mortality.
RESULTS: The search yielded 382 studies for inclusion. Of these, 58 articles were analyzed and their data extracted. The total number of patients included was 40,381 (39,568 surgical aortic valve replacement and 813 transcatheter aortic valve replacement). Perioperative (odds ratio: 1.54; 95% confidence interval: 1.25 to 1.91) and overall (i.e., perioperative and post-operative) mortality (hazard ratio: 1.26; 95% confidence interval: 1.16 to 1.36) was increased in patients with PPM. The impact of PPM on mortality was higher in those studies in which the mean age of the patients was <70 years of age (and/or AVR with associated coronary artery bypass graft was included). Severe PPM was associated with increased risk of both perioperative and overall mortality, whereas moderate PPM was associated with increased risk of perioperative mortality but not of overall mortality. The impact of PPM was less pronounced in patients with larger body mass index (>28 kg/m(2)) compared with those with lower index. Predictors of PPM were older age, female sex, hypertension, diabetes, renal failure, larger body surface area, larger body mass index, and the utilization of a bioprosthesis.
CONCLUSIONS: PPM increases perioperative and overall mortality proportionally to its severity. The identification of predictors for PPM may be useful to identify patients who are at higher risk for PPM. The findings of this study support the implementation of strategies to prevent PPM especially in patients <70 years of age and/or with concomitant coronary artery bypass graft.
Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic stenosis; aortic valve replacement; heart valve prosthesis; meta-analysis; prosthesis-patient mismatch

Mesh:

Year:  2016        PMID: 27236530     DOI: 10.1016/j.jcmg.2015.10.026

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  32 in total

1.  A mechanistic investigation of the EDWARDS INTUITY Elite valve's hemodynamic performance.

Authors:  Vahid Sadri; Charles H Bloodworth; Immanuel David Madukauwa-David; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-06-27

2.  Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

Authors:  John T Saxon; Keith B Allen; David J Cohen; Adnan K Chhatriwalla
Journal:  Interv Cardiol       Date:  2018-01

3.  The impact of age on the postoperative response of the diastolic function and left ventricular mass regression after surgical or transcatheter aortic valve replacement for severe aortic stenosis.

Authors:  Teruya Nakamura; Koichi Toda; Toru Kuratani; Shigeru Miyagawa; Yasushi Yoshikawa; Satsuki Fukushima; Shunsuke Saito; Yoshiki Sawa
Journal:  Surg Today       Date:  2016-12-24       Impact factor: 2.549

4.  Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.

Authors:  Abid Iqbal; Varghese Thomas Panicker; Jayakumar Karunakaran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-08-28

5.  Aortic root widening: "pro et contra".

Authors:  Balaji Srimurugan; Neethu Krishna; Rajesh Jose; Kirun Gopal; Praveen Kerala Varma
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-02-22

Review 6.  Prosthesis-patient mismatch after transcatheter aortic valve implantation.

Authors:  Masaki Miyasaka
Journal:  Cardiovasc Interv Ther       Date:  2022-06-16

7.  Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively.

Authors:  Delphine Szecel; Marie Lamberigts; Filip Rega; Peter Verbrugghe; Christophe Dubois; Bart Meuris
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

Review 8.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

Review 9.  Prosthesis-patient mismatch - what cardiac anesthesiologists need to know?

Authors:  Kathirvel Subramaniam; Soheyla Nazarnia
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

Review 10.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.