Literature DB >> 35708855

Prosthesis-patient mismatch after transcatheter aortic valve implantation.

Masaki Miyasaka1.   

Abstract

Prosthesis-patient mismatch (PPM), first described in 1978, occurs when a prosthetic valve functions normally, but has an effective orifice area that is too small relative to the patient's body surface area. It results in residual left ventricular afterload and higher transvalvular pressure gradient, which has been considered to impair prognosis. PPM following surgical aortic replacement is reportedly associated with worse clinical outcomes, such as high mortality. However, the impact of PPM on clinical outcomes after transcatheter aortic valve implantation (TAVI) remains unclear. There is conflicting evidence on the impact of PPM following TAVI due to differences across studies in terms of follow-up period, methods, patient populations, and type of bioprosthetic valve. The present review summarizes the most recent evidence on PPM after TAVI.
© 2022. The Author(s) under exclusive licence to Japanese Association of Cardiovascular Intervention and Therapeutics.

Entities:  

Keywords:  Clinical outcomes; Predicted effective orifice area; Predictor; Prevention; Prosthesis–patient mismatch; Racial differences

Mesh:

Year:  2022        PMID: 35708855     DOI: 10.1007/s12928-022-00865-z

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  79 in total

Review 1.  The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years.

Authors:  Stuart J Head; Mostafa M Mokhles; Ruben L J Osnabrugge; Philippe Pibarot; Michael J Mack; Johanna J M Takkenberg; Ad J J C Bogers; Arie Pieter Kappetein
Journal:  Eur Heart J       Date:  2012-03-08       Impact factor: 29.983

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

Review 3.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

4.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

5.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

6.  Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

Authors:  Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

7.  Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques.

Authors:  A P Yoganathan; E G Cape; H W Sung; F P Williams; A Jimoh
Journal:  J Am Coll Cardiol       Date:  1988-11       Impact factor: 24.094

Review 8.  Patient-prosthesis mismatch following aortic valve replacement.

Authors:  Rajdeep Bilkhu; Marjan Jahangiri; Catherine M Otto
Journal:  Heart       Date:  2019-03       Impact factor: 5.994

9.  Transcatheter aortic-valve replacement with a self-expanding prosthesis.

Authors:  David H Adams; Jeffrey J Popma; Michael J Reardon; Steven J Yakubov; Joseph S Coselli; G Michael Deeb; Thomas G Gleason; Maurice Buchbinder; James Hermiller; Neal S Kleiman; Stan Chetcuti; John Heiser; William Merhi; George Zorn; Peter Tadros; Newell Robinson; George Petrossian; G Chad Hughes; J Kevin Harrison; John Conte; Brijeshwar Maini; Mubashir Mumtaz; Sharla Chenoweth; Jae K Oh
Journal:  N Engl J Med       Date:  2014-03-29       Impact factor: 91.245

Review 10.  The problem of valve prosthesis-patient mismatch.

Authors:  S H Rahimtoola
Journal:  Circulation       Date:  1978-07       Impact factor: 29.690

View more