Radiofrequency Ablation, MR Thermometry, and High-Spatial-Resolution MR Parametric Imaging with a Single, Minimally Invasive Device.

M Arcan Ertürk1, Shashank Sathyanarayana Hegde1, Paul A Bottomley1.   

Abstract

Purpose To develop and demonstrate in vitro and in vivo a single interventional magnetic resonance (MR)-active device that integrates the functions of precise identification of a tissue site with the delivery of radiofrequency (RF) energy for ablation, high-spatial-resolution thermal mapping to monitor thermal dose, and quantitative MR imaging relaxometry to document ablation-induced tissue changes for characterizing ablated tissue. Materials and Methods All animal studies were approved by the institutional animal care and use committee. A loopless MR imaging antenna composed of a tuned microcable either 0.8 or 2.2 mm in diameter with an extended central conductor was switched between a 3-T MR imaging unit and an RF power source to monitor and perform RF ablation in bovine muscle and human artery samples in vitro and in rabbits in vivo. High-spatial-resolution (250-300-μm) proton resonance frequency shift MR thermometry was interleaved with ablations. Quantitative spin-lattice (T1) and spin-spin (T2) relaxation time MR imaging mapping was performed before and after ablation. These maps were compared with findings from gross tissue examination of the region of ablated tissue after MR imaging. Results High-spatial-resolution MR imaging afforded temperature mapping in less than 8 seconds for monitoring ablation temperatures in excess of 85°C delivered by the same device. This produced irreversible thermal injury and necrosis. Quantitative MR imaging relaxation time maps demonstrated up to a twofold variation in mean regional T1 and T2 after ablation versus before ablation. Conclusion A simple, integrated, minimally invasive interventional probe that provides image-guided therapy delivery, thermal mapping of dose, and detection of ablation-associated MR imaging parametric changes was developed and demonstrated. With this single-device approach, coupling-related safety concerns associated with multiple conductor approaches were avoided. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2016        PMID: 27228330      PMCID: PMC5131833          DOI: 10.1148/radiol.2016151447

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  22 in total

1.  Quantifying tissue damage due to focused ultrasound heating observed by MRI.

Authors:  S J Graham; L Chen; M Leitch; R D Peters; M J Bronskill; F S Foster; R M Henkelman; D B Plewes
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

2.  Development of an intravascular heating source using an MR imaging guidewire.

Authors:  Bensheng Qiu; Christopher J Yeung; Xiangying Du; Ergin Atalar; Xiaoming Yang
Journal:  J Magn Reson Imaging       Date:  2002-12       Impact factor: 4.813

3.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

4.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast.

Authors:  Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu
Journal:  AJR Am J Roentgenol       Date:  2004-08       Impact factor: 3.959

5.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Intravascular magnetic resonance imaging using a loopless catheter antenna.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

7.  RLSQ: T1, T2, and rho calculations, combining ratios and least squares.

Authors:  J J In den Kleef; J J Cuppen
Journal:  Magn Reson Med       Date:  1987-12       Impact factor: 4.668

8.  Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil.

Authors:  Nelly A Volland; Eugene G Kholmovski; Dennis L Parker; J Rock Hadley
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

Review 9.  Thresholds for thermal damage to normal tissues: an update.

Authors:  Pavel S Yarmolenko; Eui Jung Moon; Chelsea Landon; Ashley Manzoor; Daryl W Hochman; Benjamin L Viglianti; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

10.  Considerations for thermal injury analysis for RF ablation devices.

Authors:  Isaac A Chang
Journal:  Open Biomed Eng J       Date:  2010-02-04
View more
  7 in total

1.  MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation.

Authors:  Akbar Alipour; Eric S Meyer; Charles L Dumoulin; Ronald D Watkins; Hassan Elahi; Wolfgang Loew; Jeffrey Schweitzer; Gregory Olson; Yue Chen; Susumu Tao; Michael Guttman; Aravindan Kolandaivelu; Henry R Halperin; Ehud J Schmidt
Journal:  IEEE Trans Biomed Eng       Date:  2019-09-13       Impact factor: 4.538

Review 2.  Contactless Thermometry by MRI and MRS: Advanced Methods for Thermotherapy and Biomaterials.

Authors:  Norbert W Lutz; Monique Bernard
Journal:  iScience       Date:  2020-09-14

3.  High-resolution intravascular MRI-guided perivascular ultrasound ablation.

Authors:  Xiaoyang Liu; Nicholas Ellens; Emery Williams; Everette C Burdette; Parag Karmarkar; Clifford R Weiss; Dara Kraitchman; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2019-08-11       Impact factor: 4.668

4.  A Combined Intravascular MRI Endoscope and Intravascular Ultrasound (IVUS) Transducer for High-Resolution Image-Guided Ablation.

Authors:  Xiaoyang Liu; Nicholas Ellens; Emery Williams; Everette Clif Burdette; Parag Karmarkar; Paul Bottomley
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2017-04

5.  Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo.

Authors:  Solenn Toupin; Pierre Bour; Matthieu Lepetit-Coiffé; Valéry Ozenne; Baudouin Denis de Senneville; Rainer Schneider; Alexis Vaussy; Arnaud Chaumeil; Hubert Cochet; Frédéric Sacher; Pierre Jaïs; Bruno Quesson
Journal:  J Cardiovasc Magn Reson       Date:  2017-01-25       Impact factor: 5.364

6.  Sensor-Based Automated Detection of Electrosurgical Cautery States.

Authors:  Josh Ehrlich; Amoon Jamzad; Mark Asselin; Jessica Robin Rodgers; Martin Kaufmann; Tamas Haidegger; John Rudan; Parvin Mousavi; Gabor Fichtinger; Tamas Ungi
Journal:  Sensors (Basel)       Date:  2022-08-03       Impact factor: 3.847

7.  Interventional cardiac magnetic resonance imaging: current applications, technology readiness level, and future perspectives.

Authors:  Sophie C Rier; Suzan Vreemann; Wouter H Nijhof; Vincent J H M van Driel; Ivo A C van der Bilt
Journal:  Ther Adv Cardiovasc Dis       Date:  2022 Jan-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.