PURPOSE: To develop a fast and robust method to resolve phase ambiguity in dual-echo Dixon imaging. METHODS: A major challenge in dual-echo Dixon imaging is to estimate the phase error resulting from field inhomogeneity. In this work, a binary quadratic optimization program was formulated to resolve the phase ambiguity. A projected power method was developed to efficiently solve the optimization problem. Both the 1-peak fat model and 6-peak fat model were applied to three-dimensional (3D) datasets. Additionally, the proposed method was extended to dynamic magnetic resonance imaging (MRI) applications using the 6-peak fat model. With institutional review board (IRB) approval and patient consent/assent, the proposed method was evaluated and compared with region growing on 29 consecutive 3D high-resolution patient datasets. RESULTS: Fast and robust water/fat separation was achieved by the proposed method in different representative 3D datasets and dynamic 3D datasets. Superior water/fat separation was achieved using the 6-peak fat model compared with the 1-peak fat model. Compared to region growing, the proposed method reduced water/fat swaps from 76 to 7% of the patient cohort. CONCLUSION: The proposed method can achieve fast and robust phase error estimation in dual-echo Dixon imaging. Magn Reson Med 77:2066-2076, 2017.
PURPOSE: To develop a fast and robust method to resolve phase ambiguity in dual-echo Dixon imaging. METHODS: A major challenge in dual-echo Dixon imaging is to estimate the phase error resulting from field inhomogeneity. In this work, a binary quadratic optimization program was formulated to resolve the phase ambiguity. A projected power method was developed to efficiently solve the optimization problem. Both the 1-peak fat model and 6-peak fat model were applied to three-dimensional (3D) datasets. Additionally, the proposed method was extended to dynamic magnetic resonance imaging (MRI) applications using the 6-peak fat model. With institutional review board (IRB) approval and patient consent/assent, the proposed method was evaluated and compared with region growing on 29 consecutive 3D high-resolution patient datasets. RESULTS: Fast and robust water/fat separation was achieved by the proposed method in different representative 3D datasets and dynamic 3D datasets. Superior water/fat separation was achieved using the 6-peak fat model compared with the 1-peak fat model. Compared to region growing, the proposed method reduced water/fat swaps from 76 to 7% of the patient cohort. CONCLUSION: The proposed method can achieve fast and robust phase error estimation in dual-echo Dixon imaging. Magn Reson Med 77:2066-2076, 2017.
Authors: Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase Journal: Magn Reson Med Date: 2002-06 Impact factor: 4.668
Authors: Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc Journal: Magn Reson Med Date: 2005-09 Impact factor: 4.668
Authors: Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig Journal: Magn Reson Med Date: 2014-03 Impact factor: 4.668
Authors: Kevin Looby; Carl D Herickhoff; Christopher Sandino; Tao Zhang; Shreyas Vasanawala; Jeremy J Dahl Journal: J Med Imaging (Bellingham) Date: 2019-07-22
Authors: Akshay S Chaudhari; Bragi Sveinsson; Catherine J Moran; Emily J McWalter; Ethan M Johnson; Tao Zhang; Garry E Gold; Brian A Hargreaves Journal: Magn Reson Med Date: 2017-01-11 Impact factor: 4.668
Authors: Beata Bachrata; Bernhard Strasser; Wolfgang Bogner; Albrecht Ingo Schmid; Radim Korinek; Martin Krššák; Siegfried Trattnig; Simon Daniel Robinson Journal: Magn Reson Med Date: 2020-09-27 Impact factor: 4.668