Literature DB >> 27193744

The benefit of HH during the CPAP titration in the cool sleeping environment.

Yayong Li1, Yina Wang2.   

Abstract

PURPOSE: Upper airway symptom associated with continuous positive airway pressure (CPAP) treatment is an important factor influencing CPAP adherence. There are conflicting data on the effect of a heated humidifier (HH) during CPAP titration for patients with obstructive sleep apnea hypopnea syndrome (OSAHS). This study investigated the effects of HH during CPAP titration in the cool sleeping environment.
METHODS: Forty newly diagnosed OSAHS patients who received CPAP titration in the cool sleeping environment were randomly assigned to HH and non-HH groups. A questionnaire was used to evaluate upper airway symptoms, satisfaction with initial CPAP treatment, and willingness to further use CPAP. Some therapy parameters including leak, apnea hypopnea index (AHI) reduction, and optimal CPAP pressure level were analyzed. We compared these subjective and objective data between the two groups.
RESULTS: In subjective sensation, the use of HH can alleviate upper airway symptoms associated with CPAP titration (P < 0.001). The HH group has benefit in satisfaction with initial CPAP treatment (P < 0.001) and further willingness to use CPAP (P < 0.01), although there were no significant differences in leak, AHI reduction, and optimal CPAP pressure between the two groups.
CONCLUSIONS: The use of HH is recommended during CPAP titration in the cool sleeping environment because of its benefit in the treatment of upper airway symptoms associated with CPAP therapy and improvement of the CPAP acceptance.

Entities:  

Keywords:  Continuous positive airway pressure; Heated humidifier; Obstructive sleep apnea hypopnea syndrome

Mesh:

Year:  2016        PMID: 27193744     DOI: 10.1007/s11325-016-1354-8

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  25 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  Efficiency of cold passover and heated humidification under continuous positive airway pressure.

Authors:  W J Randerath; J Meier; H Genger; U Domanski; K H Rühle
Journal:  Eur Respir J       Date:  2002-07       Impact factor: 16.671

3.  Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure.

Authors:  C A Massie; R W Hart; K Peralez; G N Richards
Journal:  Chest       Date:  1999-08       Impact factor: 9.410

Review 4.  A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions.

Authors:  Amy M Sawyer; Nalaka S Gooneratne; Carole L Marcus; Dafna Ofer; Kathy C Richards; Terri E Weaver
Journal:  Sleep Med Rev       Date:  2011-06-08       Impact factor: 11.609

5.  Effect of heated humidification on compliance and quality of life in patients with sleep apnea using nasal continuous positive airway pressure.

Authors:  M Jeffery Mador; Matthew Krauza; Adnan Pervez; Dawn Pierce; Mark Braun
Journal:  Chest       Date:  2005-10       Impact factor: 9.410

6.  Initiation of CPAP therapy for OSA: does prophylactic humidification during CPAP pressure titration improve initial patient acceptance and comfort?

Authors:  G H Wiest; I A Harsch; F S Fuchs; S Kitzbichler; K Bogner; W M Brueckl; E G Hahn; J H Ficker
Journal:  Respiration       Date:  2002       Impact factor: 3.580

7.  Nasal breathing and continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA).

Authors:  Jan H Hollandt; Malte Mahlerwein
Journal:  Sleep Breath       Date:  2003-06       Impact factor: 2.816

8.  Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers.

Authors:  J L Pépin; P Leger; D Veale; B Langevin; D Robert; P Lévy
Journal:  Chest       Date:  1995-02       Impact factor: 9.410

9.  Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.

Authors:  Clete A Kushida; Alejandro Chediak; Richard B Berry; Lee K Brown; David Gozal; Conrad Iber; Sairam Parthasarathy; Stuart F Quan; James A Rowley
Journal:  J Clin Sleep Med       Date:  2008-04-15       Impact factor: 4.062

10.  The effects of heated humidifier in continuous positive airway pressure titration.

Authors:  Chung-Chieh Yu; Cheng-Ming Luo; Yu-Chih Liu; Huang-Pin Wu
Journal:  Sleep Breath       Date:  2012-02-04       Impact factor: 2.816

View more
  2 in total

1.  Effects of heated humidifier during CPAP titration in the cool sleeping environment.

Authors:  Maria Vargas; Antonio M Esquinas Rodriguez
Journal:  Sleep Breath       Date:  2016-08-15       Impact factor: 2.816

2.  Author response to: Effects of heated humidifier during CPAP titration in the cool sleeping environment.

Authors:  Yayong Li; Yina Wang
Journal:  Sleep Breath       Date:  2016-08-15       Impact factor: 2.816

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.