Literature DB >> 12232447

Initiation of CPAP therapy for OSA: does prophylactic humidification during CPAP pressure titration improve initial patient acceptance and comfort?

G H Wiest1, I A Harsch, F S Fuchs, S Kitzbichler, K Bogner, W M Brueckl, E G Hahn, J H Ficker.   

Abstract

BACKGROUND: Heated humidifiers (HH) enable effective treatment of upper airway dryness during nasal continuous positive airway pressure (nCPAP) therapy for obstructive sleep apnoea (OSA), but the role of prophylactic use of HH during the initiation of nCPAP treatment has not been studied so far.
OBJECTIVES: The aim of the present study was to investigate whether prophylactic HH during the initiation of CPAP would result in improved initial patient comfort and acceptance.
METHODS: In 44 consecutive, previously untreated OSA patients with no history of upper airway dryness, CPAP titration with and without HH was performed on two consecutive nights in a randomised order. The patients were interviewed after each treatment night in order to establish the comfort of the treatment, and, after the second treatment, they were asked which of the two nights they considered more pleasant, and which treatment they would prefer for long-term use.
RESULTS: Following CPAP titration with HH, 32 patients (73%) claimed to have had a better night's sleep than usual (i.e. without CPAP treatment) compared with 33 patients (75%) saying the same following CPAP treatment without HH. For 21 patients (47.7%) treatment with HH was more pleasant, 23 (52.3%) saw no difference or said that treatment without HH was more pleasant. Nineteen patients (43.2%) gave preference to treatment with HH for long-term use, while 25 patients (56.8%) had no preference or said they would prefer treatment without HH.
CONCLUSIONS: The use of HH during the initiation phase of CPAP treatment was associated neither with an initial improvement in comfort nor with greater initial treatment acceptance. Copyright 2002 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2002        PMID: 12232447     DOI: 10.1159/000064016

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  10 in total

Review 1.  Continuous positive airway pressure reduces risk of motor vehicle crash among drivers with obstructive sleep apnea: systematic review and meta-analysis.

Authors:  Stephen Tregear; James Reston; Karen Schoelles; Barbara Phillips
Journal:  Sleep       Date:  2010-10       Impact factor: 5.849

2.  Quality of life, compliance, sleep and nasopharyngeal side effects during CPAP therapy with and without controlled heated humidification.

Authors:  Karl-Heinz Ruhle; Karl-Josef Franke; Ulrike Domanski; Georg Nilius
Journal:  Sleep Breath       Date:  2010-05-26       Impact factor: 2.816

3.  Effect of APAP and heated humidification with a heated breathing tube on adherence, quality of life, and nasopharyngeal complaints.

Authors:  Georg Nilius; Karl J Franke; Ulrike Domanski; Maik Schroeder; Karl H Ruhle
Journal:  Sleep Breath       Date:  2015-05-10       Impact factor: 2.816

4.  Effects of heated humidifier during CPAP titration in the cool sleeping environment.

Authors:  Maria Vargas; Antonio M Esquinas Rodriguez
Journal:  Sleep Breath       Date:  2016-08-15       Impact factor: 2.816

5.  Best clinical practices for the sleep center adjustment of noninvasive positive pressure ventilation (NPPV) in stable chronic alveolar hypoventilation syndromes.

Authors:  Richard B Berry; Alejandro Chediak; Lee K Brown; Jonathan Finder; David Gozal; Conrad Iber; Clete A Kushida; Timothy Morgenthaler; James A Rowley; Sally L Davidson-Ward
Journal:  J Clin Sleep Med       Date:  2010-10-15       Impact factor: 4.062

Review 6.  Effects of heated humidification on positive airway pressure side effects in patients with obstructive sleep apnoea: a meta-analysis.

Authors:  Yuli Hu; Zuoyan Zhang; Fang Fang; Jiaxin Yang; Jun Ma; Sanlian Hu; Jian Guan
Journal:  Sleep Breath       Date:  2022-03-28       Impact factor: 2.816

7.  Telemedicine-based proactive patient management during positive airway pressure therapy: Impact on therapy termination rate.

Authors:  Holger Woehrle; Joachim H Ficker; Andrea Graml; Ingo Fietze; Peter Young; Helmut Teschler; Michael Arzt
Journal:  Somnologie (Berl)       Date:  2017-01-23

8.  The benefit of HH during the CPAP titration in the cool sleeping environment.

Authors:  Yayong Li; Yina Wang
Journal:  Sleep Breath       Date:  2016-05-18       Impact factor: 2.816

9.  The effects of heated humidifier in continuous positive airway pressure titration.

Authors:  Chung-Chieh Yu; Cheng-Ming Luo; Yu-Chih Liu; Huang-Pin Wu
Journal:  Sleep Breath       Date:  2012-02-04       Impact factor: 2.816

10.  Pressure modification or humidification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea.

Authors:  Barry Kennedy; Toby J Lasserson; Dariusz R Wozniak; Ian Smith
Journal:  Cochrane Database Syst Rev       Date:  2019-12-02
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.