Literature DB >> 10453869

Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure.

C A Massie1, R W Hart, K Peralez, G N Richards.   

Abstract

STUDY
OBJECTIVES: To evaluate the effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure (CPAP).
DESIGN: A randomized, crossover design was employed.
SETTING: The study was conducted at two suburban community-based hospital sleep laboratories. PATIENTS: Data were collected on 38 obstructive sleep apnea patients (mean age, 44.1 years) in whom CPAP was a novel treatment.
INTERVENTIONS: The interventions were heated humidity, cold passover humidity, and a washout period without humidity. MEASUREMENTS AND
RESULTS: Patients were titrated with heated humidity or cold passover humidity in the laboratory and subsequently initiated on humidity. Objective compliance, self-report of factors affecting CPAP use, satisfaction with CPAP, feeling upon awakening, and daytime sleepiness were assessed at the completion of each 3-week treatment period and a 2-week washout period. Outcome measures were assessed with one-way analysis of variance followed by Scheffe post hoc comparisons. Significant main effects were observed for compliance (F2,37 = 5.2; p = 0.008), satisfaction with CPAP (F2,37 = 4.5; p = 0.01), and feeling refreshed on awakening (F2,37 = 4.4; p = 0.02). A significant decrease in daytime sleepiness was observed between baseline and each of the conditions (F3,37 = 55.5; p<0.0001), but Epworth sleepiness scale scores did not differ between conditions (all p values >0.56). CPAP use with heated humidity (5.52+/-2.1 h/night) was greater than CPAP use without humidity (4.93+/-2.2 h/night; p = 0.008). Compliance differences were not observed between CPAP use with cold passover humidity and CPAP use without humidity. Patients were more satisfied with CPAP when it was used with heated or cold passover humidity (p< or =0.05). However, only heated humidity resulted in feeling more refreshed on awakening (p<0.05). No significant differences were observed among the three groups on the global adverse side effect score (F2,37 = 2.5; p = 0.09). Specific side effects such as dry mouth or throat and dry nose were reported less frequently when CPAP was used with heated humidity compared to CPAP use without humidity (p<0.001).
CONCLUSIONS: Compliance with CPAP is enhanced when heated humidification is employed. This is likely due to a reduction in side effects associated with upper airway symptoms and a more refreshed feeling upon awakening. Compliance gains may be realized sooner if patients are started with heated humidity at CPAP initiation.

Entities:  

Mesh:

Year:  1999        PMID: 10453869     DOI: 10.1378/chest.116.2.403

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  64 in total

1.  Effect of tubing condensate on non-invasive positive pressure ventilators tested under simulated clinical conditions.

Authors:  Diana Elizabeth Hart; Mark Forman; Andrew G Veale
Journal:  Sleep Breath       Date:  2010-07-29       Impact factor: 2.816

2.  Quality of life, compliance, sleep and nasopharyngeal side effects during CPAP therapy with and without controlled heated humidification.

Authors:  Karl-Heinz Ruhle; Karl-Josef Franke; Ulrike Domanski; Georg Nilius
Journal:  Sleep Breath       Date:  2010-05-26       Impact factor: 2.816

Review 3.  New developments in the use of positive airway pressure for obstructive sleep apnea.

Authors:  Lucas M Donovan; Schafer Boeder; Atul Malhotra; Sanjay R Patel
Journal:  J Thorac Dis       Date:  2015-08       Impact factor: 2.895

4.  Response to "Effect of APAP and heated humidification with a heated breathing tube on adherence, quality of life, and nasopharyngeal complaints".

Authors:  Georg Nilius
Journal:  Sleep Breath       Date:  2015-10-17       Impact factor: 2.816

5.  Effect of APAP and heated humidification with a heated breathing tube on adherence, quality of life, and nasopharyngeal complaints.

Authors:  A Ozsancak Ugurlu; A M Esquinas
Journal:  Sleep Breath       Date:  2015-10-17       Impact factor: 2.816

Review 6.  Sleep.7: positive airway pressure therapy for obstructive sleep apnoea/hypopnoea syndrome.

Authors:  P Gordon; M H Sanders
Journal:  Thorax       Date:  2005-01       Impact factor: 9.139

Review 7.  Clinical review: humidifiers during non-invasive ventilation--key topics and practical implications.

Authors:  Antonio M Esquinas Rodriguez; Raffaele Scala; Arie Soroksky; Ahmed BaHammam; Alan de Klerk; Arschang Valipour; Davide Chiumello; Claude Martin; Anne E Holland
Journal:  Crit Care       Date:  2012-02-08       Impact factor: 9.097

8.  Working memory in obstructive sleep apnea: construct validity and treatment effects.

Authors:  Joshua C Felver-Gant; Amanda S Bruce; Molly Zimmerman; Lawrence H Sweet; Richard P Millman; Mark S Aloia
Journal:  J Clin Sleep Med       Date:  2007-10-15       Impact factor: 4.062

9.  Water content of delivered gases during non-invasive ventilation in healthy subjects.

Authors:  François Lellouche; Salvatore Maurizio Maggiore; Aissam Lyazidi; Nicolas Deye; Solenne Taillé; Laurent Brochard
Journal:  Intensive Care Med       Date:  2009-03-18       Impact factor: 17.440

10.  Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal continuous positive airway pressure.

Authors:  Silke Ryan; Liam S Doherty; Geraldine M Nolan; Walter T McNicholas
Journal:  J Clin Sleep Med       Date:  2009-10-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.