Literature DB >> 18468315

Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.

Clete A Kushida1, Alejandro Chediak, Richard B Berry, Lee K Brown, David Gozal, Conrad Iber, Sairam Parthasarathy, Stuart F Quan, James A Rowley.   

Abstract

Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBDs), including obstructive sleep apnea (OSA). After a patient is diagnosed with OSA, the current standard of practice involves performing attended polysomnography (PSG), during which positive airway pressure is adjusted throughout the recording period to determine the optimal pressure for maintaining upper airway patency. Continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BPAP) represent the two forms of PAP that are manually titrated during PSG to determine the single fixed pressure of CPAP or the fixed inspiratory and expiratory positive airway pressures (IPAP and EPAP, respectively) of BPAP for subsequent nightly usage. A PAP Titration Task Force of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Task Force developed these recommendations for conducting CPAP and BPAP titrations. Major recommendations are as follows: (1) All potential PAP titration candidates should receive adequate PAP education, hands-on demonstration, careful mask fitting, and acclimatization prior to titration. (2) CPAP (IPAP and/or EPAP for patients on BPAP) should be increased until the following obstructive respiratory events are eliminated (no specific order) or the recommended maximum CPAP (IPAP for patients on BPAP) is reached: apneas, hypopneas, respiratory effort-related arousals (RERAs), and snoring. (3) The recommended minimum starting CPAP should be 4 cm H2O for pediatric and adult patients, and the recommended minimum starting IPAP and EPAP should be 8 cm H2O and 4 cm H2O, respectively, for pediatric and adult patients on BPAP. (4) The recommended maximum CPAP should be 15 cm H2O (or recommended maximum IPAP of 20 cm H2O if on BPAP) for patients < 12 years, and 20 cm H2O (or recommended maximum IPAP of 30 cm H2O if on BPAP) for patients > or = 12 years. (5) The recommended minimum IPAP-EPAP differential is 4 cm H2O and the recommended maximum IPAP-EPAP differential is 10 cm H2O (6) CPAP (IPAP and/or EPAP for patients on BPAP depending on the type of event) should be increased by at least 1 cm H2O with an interval no shorter than 5 min, with the goal of eliminating obstructive respiratory events. (7) CPAP (IPAP and EPAP for patients on BPAP) should be increased from any CPAP (or IPAP) level if at least 1 obstructive apnea is observed for patients < 12 years, or if at least 2 obstructive apneas are observed for patients > or = 12 years. (8) CPAP (IPAP for patients on BPAP) should be increased from any CPAP (or IPAP) level if at least 1 hypopnea is observed for patients < 12 years, or if at least 3 hypopneas are observed for patients > or = 12 years. (9) CPAP (IPAP for patients on BPAP) should be increased from any CPAP (or IPAP) level if at least 3 RERAs are observed for patients < 12 years, or if at least 5 RERAs are observed for patients > or = 12 years. (10) CPAP (IPAP for patients on BPAP) may be increased from any CPAP (or IPAP) level if at least 1 min of loud or unambiguous snoring is observed for patients < 12 years, or if at least 3 min of loud or unambiguous snoring are observed for patients > or = 12 years. (11) The titration algorithm for split-night CPAP or BPAP titration studies should be identical to that of full-night CPAP or BPAP titration studies, respectively. (12) If the patient is uncomfortable or intolerant of high pressures on CPAP, the patient may be tried on BPAP. If there are continued obstructive respiratory events at 15 cm H2O of CPAP during the titration study, the patient may be switched to BPAP. (13) The pressure of CPAP or BPAP selected for patient use following the titration study should reflect control of the patient's obstructive respiration by a low (preferably < 5 per hour) respiratory disturbance index (RDI) at the selected pressure, a minimum sea level SpO2 above 90% at the pressure, and with a leak within acceptable parameters at the pressure.) (14) An optimal titration reduces RDI < 5 for at least a 15-min duration and should include supine REM sleep at the selected pressure that is not continually interrupted by spontaneous arousals or awakenings. (15) A good titration reduces RDI < or = 10 or by 50% if the baseline RDI < 15 and should include supine REM sleep that is not continually interrupted by spontaneous arousals or awakenings at the selected pressure. (16) An adequate titration does not reduce the RDI < or = 10 but reduces the RDI by 75% from baseline (especially in severe OSA patients), or one in which the titration grading criteria for optimal or good are met with the exception that supine REM sleep did not occur at the selected pressure. (17) An unacceptable titration is one that does not meet any one of the above grades. (18) A repeat PAP titration study should be considered if the initial titration does not achieve a grade of optimal or good and, if it is a split-night PSG study, it fails to meet AASM criteria (i.e., titration duration should be > 3 hr).

Entities:  

Mesh:

Year:  2008        PMID: 18468315      PMCID: PMC2335396     

Source DB:  PubMed          Journal:  J Clin Sleep Med        ISSN: 1550-9389            Impact factor:   4.062


  109 in total

1.  Acceptance and long-term compliance with nCPAP in patients with obstructive sleep apnoea syndrome.

Authors:  T Pieters; P Collard; G Aubert; M Dury; P Delguste; D O Rodenstein
Journal:  Eur Respir J       Date:  1996-05       Impact factor: 16.671

2.  Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report.

Authors:  Michael Littner; Maxwell Hirshkowitz; David Davila; W McDowell Anderson; Clete A Kushida; B Tucker Woodson; Stephen F Johnson; S Wise Merrill
Journal:  Sleep       Date:  2002-03-15       Impact factor: 5.849

Review 3.  Rules of evidence and clinical recommendations for the management of patients.

Authors:  D L Sackett
Journal:  Can J Cardiol       Date:  1993 Jul-Aug       Impact factor: 5.223

4.  Prevalence of persistent sleep apnea in patients treated with continuous positive airway pressure.

Authors:  Marcel A Baltzan; Ibrahim Kassissia; Osama Elkholi; Mark Palayew; Richard Dabrusin; Norman Wolkove
Journal:  Sleep       Date:  2006-04       Impact factor: 5.849

5.  Automatic pressure titration with APAP is as effective as manual titration with CPAP in patients with obstructive sleep apnea.

Authors:  Ingo Fietze; Martin Glos; Isabel Moebus; Christian Witt; Thomas Penzel; Gert Baumann
Journal:  Respiration       Date:  2007-02-23       Impact factor: 3.580

6.  Treatment adherence and outcomes in flexible vs standard continuous positive airway pressure therapy.

Authors:  Mark S Aloia; Michael Stanchina; J Todd Arnedt; Atul Malhotra; Richard P Millman
Journal:  Chest       Date:  2005-06       Impact factor: 9.410

7.  Reproducibility of a standardized titration procedure for the initiation of continuous positive airway pressure therapy in patients with obstructive sleep apnoea.

Authors:  G H Wiest; F S Fuchs; I A Harsch; S Pour Schahin; S Lampert; W M Brueckl; E G Hahn; J H Ficker
Journal:  Respiration       Date:  2001       Impact factor: 3.580

8.  Comparison of conventional nighttime with automatic or manual daytime CPAP titration in unselected sleep apnea patients: study of the usefulness of daytime titration studies.

Authors:  Patricia Lloberes; Benito Rodríguez; Antonio Roca; M Teresa Sagales; M Dolores de la Calzada; Sandra Giménez; Odile Romero; Gabriel Sampol
Journal:  Respir Med       Date:  2004-07       Impact factor: 3.415

9.  Treatment of obstructive sleep apnea in pediatric patients. Behavioral intervention for compliance with nasal continuous positive airway pressure.

Authors:  J C Rains
Journal:  Clin Pediatr (Phila)       Date:  1995-10       Impact factor: 1.168

10.  Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine.

Authors:  Nancy A Collop; W McDowell Anderson; Brian Boehlecke; David Claman; Rochelle Goldberg; Daniel J Gottlieb; David Hudgel; Michael Sateia; Richard Schwab
Journal:  J Clin Sleep Med       Date:  2007-12-15       Impact factor: 4.062

View more
  182 in total

1.  Determination of new prediction formula for nasal continuous positive airway pressure in Turkish patients with obstructive sleep apnea syndrome.

Authors:  Ozen K Basoglu; Mehmet Sezai Tasbakan
Journal:  Sleep Breath       Date:  2011-11-12       Impact factor: 2.816

2.  Adherence to continuous positive airway pressure therapy in obstructive sleep apnea syndrome: effect of visual education.

Authors:  Ozen K Basoglu; Meltem Midilli; Rasit Midilli; Cem Bilgen
Journal:  Sleep Breath       Date:  2011-12-14       Impact factor: 2.816

3.  Driving on "auto": hands-on is more effective than hands-free.

Authors:  Barry Krakow; Victor A Ulibarri; Jessica N Sanchez; Shara Kikta; Natalia McIver; Dominic Melendrez
Journal:  J Clin Sleep Med       Date:  2012-06-15       Impact factor: 4.062

4.  The clinical dilema: to treat or not to treat REM related obstructive sleep apnea?

Authors:  Gautam Ganguly
Journal:  Sleep       Date:  2012-06-01       Impact factor: 5.849

5.  Influence of gender on continuous positive airway pressure requirements in patients with obstructive sleep apnea syndrome.

Authors:  Gnananandh Jayaraman; Hashir Majid; Salim Surani; Christina Kao; Shyam Subramanian
Journal:  Sleep Breath       Date:  2010-11-16       Impact factor: 2.816

6.  Diagnostic accuracy of split-night polysomnograms.

Authors:  Imran S Khawaja; Eric J Olson; Christelle van der Walt; Jan Bukartyk; Virend Somers; Ross Dierkhising; Timothy I Morgenthaler
Journal:  J Clin Sleep Med       Date:  2010-08-15       Impact factor: 4.062

7.  The association of age, insomnia, and self-efficacy with continuous positive airway pressure adherence in black, white, and Hispanic U.S. Veterans.

Authors:  Douglas M Wallace; Shirin Shafazand; Mark S Aloia; William K Wohlgemuth
Journal:  J Clin Sleep Med       Date:  2013-09-15       Impact factor: 4.062

8.  Evaluation of Continuous Negative External Pressure (cNEP) for the Treatment of Obstructive Sleep Apnea: A Pilot Study.

Authors:  Jerrold A Kram; Robyn V Woidtke; Kenneth B Klein; Richard M Rose
Journal:  J Clin Sleep Med       Date:  2017-08-15       Impact factor: 4.062

9.  Insulin Resistance and Hypertension in Obese Youth With Sleep-Disordered Breathing Treated With Positive Airway Pressure: A Prospective Multicenter Study.

Authors:  Sherri L Katz; Joanna E MacLean; Lynda Hoey; Linda Horwood; Nicholas Barrowman; Bethany Foster; Stasia Hadjiyannakis; Laurent Legault; Glenda N Bendiak; Valerie G Kirk; Evelyn Constantin
Journal:  J Clin Sleep Med       Date:  2017-09-15       Impact factor: 4.062

10.  CPAP therapy in patients with idiopathic pulmonary fibrosis and obstructive sleep apnea: does it offer a better quality of life and sleep?

Authors:  Charalampos Mermigkis; Izolde Bouloukaki; Katerina M Antoniou; Demetrios Mermigkis; Kostas Psathakis; Ioannis Giannarakis; Georgios Varouchakis; Nikolaos Siafakas; Sophia E Schiza
Journal:  Sleep Breath       Date:  2013-02-06       Impact factor: 2.816

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.