Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections.

Walter R T Witschey1, Arijitt Borthakur, Mark A Elliott, Eric Mellon, Sampreet Niyogi, Daniel J Wallman, Chenyang Wang, Ravinder Reddy.   

Abstract

The origin of spin locking image artifacts in the presence of B(0) and B(1) magnetic field imperfections is shown theoretically using the Bloch equations and experimentally at low (omega(1) << Delta omega(0)), intermediate (omega(1) approximately Delta omega(0)) and high (omega(1) >> Delta omega(0)) spin locking field strengths. At low spin locking fields, the magnetization is shown to oscillate about an effective field in the rotating frame causing signature banding artifacts in the image. At high spin lock fields, the effect of the resonance offset Deltao mega(0) is quenched, but imperfections in the flip angle cause oscillations about the omega(1) field. A new pulse sequence is presented that consists of an integrated spin echo and spin lock experiment followed by magnetization storage along the -z-axis. It is shown that this sequence almost entirely eliminates banding artifacts from both types of field inhomogeneities at all spin locking field strengths. The sequence was used to obtain artifact free images of agarose in inhomogeneous B(0) and B(1) fields, off-resonance spins in fat and in vivo human brain images at 3 T. The new pulse sequence can be used to probe very low frequency (0-400 Hz) dynamic and static interactions in tissues without contaminating B(0) and B(1) field artifacts.

Entities:  

Mesh:

Year:  2007        PMID: 17291799      PMCID: PMC1995435          DOI: 10.1016/j.jmr.2007.01.015

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  23 in total

1.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

2.  Artifacts in T(1rho)-weighted imaging: correction with a self-compensating spin-locking pulse.

Authors:  Sridhar R Charagundla; Arijitt Borthakur; John S Leigh; Ravinder Reddy
Journal:  J Magn Reson       Date:  2003-05       Impact factor: 2.229

3.  Method for reduced SAR T1rho-weighted MRI.

Authors:  Andrew J Wheaton; Arijitt Borthakur; Matthew Corbo; Sridhar R Charagundla; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2004-06       Impact factor: 4.668

4.  Short perspective on "NMR population inversion using a composite pulse" by M.H. Levitt and R. Freeman [J. Magn. Reson. 33 (1979) 473-476].

Authors:  Malcolm H Levitt
Journal:  J Magn Reson       Date:  2011-09-07       Impact factor: 2.229

5.  Proton exchange as a relaxation mechanism for T1 in the rotating frame in native and immobilized protein solutions.

Authors:  H I Mäkelä; O H Gröhn; M I Kettunen; R A Kauppinen
Journal:  Biochem Biophys Res Commun       Date:  2001-12-14       Impact factor: 3.575

6.  Early detection of irreversible cerebral ischemia in the rat using dispersion of the magnetic resonance imaging relaxation time, T1rho.

Authors:  M I Kettunen; H I Mäkelä; M Penttonen; A Pitkänen; J A Lukkarinen; R A Kauppinen
Journal:  J Cereb Blood Flow Metab       Date:  2000-10       Impact factor: 6.200

7.  Indirect 17(O)-magnetic resonance imaging of cerebral blood flow in the rat.

Authors:  Dharmesh R Tailor; Arijit Roy; Ravinder R Regatte; Sridhar R Charagundla; Alan C McLaughlin; John S Leigh; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

8.  Three-dimensional T1rho-weighted MRI at 1.5 Tesla.

Authors:  Arijitt Borthakur; Andrew Wheaton; Sridhar R Charagundla; Erik M Shapiro; Ravinder R Regatte; Sarma V S Akella; J Bruce Kneeland; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2003-06       Impact factor: 4.813

9.  On- and off-resonance T(1rho) MRI in acute cerebral ischemia of the rat.

Authors:  Olli H J Gröhn; Heidi I Mäkelä; Jouko A Lukkarinen; Lance DelaBarre; Joseph Lin; Michael Garwood; Risto A Kauppinen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

10.  High-resolution assessment of blood flow in murine RIF-1 tumors by monitoring uptake of H(2)(17)O with proton T(1rho)-weighted imaging.

Authors:  Dharmesh R Tailor; Harish Poptani; Jerry D Glickson; John S Leigh; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

View more
  58 in total

1.  Magnetic resonance imaging of oscillating electrical currents.

Authors:  Nicholas W Halpern-Manners; Vikram S Bajaj; Thomas Z Teisseyre; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2010-04-26       Impact factor: 11.205

Review 2.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

3.  Assessing Myocardial Disease Using T MRI.

Authors:  Yuchi Han; Timo Liimatainen; Robert C Gorman; Walter R T Witschey
Journal:  Curr Cardiovasc Imaging Rep       Date:  2014-02-01

4.  Investigation of chemical exchange at intermediate exchange rates using a combination of chemical exchange saturation transfer (CEST) and spin-locking methods (CESTrho).

Authors:  Feliks Kogan; Anup Singh; Keija Cai; Mohammad Haris; Hari Hariharan; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2011-10-18       Impact factor: 4.668

5.  Biexponential T relaxation mapping of human knee cartilage in vivo at 3 T.

Authors:  Azadeh Sharafi; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2017-06-20       Impact factor: 4.044

6.  Ex vivo quantitative multiparametric MRI mapping of human meniscus degeneration.

Authors:  Sven Nebelung; Markus Tingart; Thomas Pufe; Christiane Kuhl; Holger Jahr; Daniel Truhn
Journal:  Skeletal Radiol       Date:  2016-09-17       Impact factor: 2.199

Review 7.  Putting it all together: established and emerging MRI techniques for detecting and measuring liver fibrosis.

Authors:  Suraj D Serai; Andrew T Trout; Alexander Miethke; Eric Diaz; Stavra A Xanthakos; Jonathan R Dillman
Journal:  Pediatr Radiol       Date:  2018-08-04

Review 8.  Novel contrast mechanisms at 3 Tesla and 7 Tesla.

Authors:  Ravinder R Regatte; Mark E Schweitzer
Journal:  Semin Musculoskelet Radiol       Date:  2008-10-10       Impact factor: 1.777

9.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04

10.  Chemical exchange in knee cartilage assessed by R1ρ (1/T1ρ) dispersion at 3T.

Authors:  Ping Wang; Jake Block; John C Gore
Journal:  Magn Reson Imaging       Date:  2014-08-02       Impact factor: 2.546

View more