Literature DB >> 2718776

The direct examination of three-dimensional bone architecture in vitro by computed tomography.

L A Feldkamp1, S A Goldstein, A M Parfitt, G Jesion, M Kleerekoper.   

Abstract

We describe a new method for the direct examination of three-dimensional bone structure in vitro based on high-resolution computed tomography (CT). Unlike clinical CT, a three-dimensional reconstruction array is created directly, rather than a series of two-dimensional slices. All structural indices commonly determined from two-dimensional histologic sections can be obtained nondestructively from a large number of slices in each of three orthogonal directions. This permits a comprehensive description of structural variation within a specimen and greatly facilitates the study of structural anisotropy. A measure of three-dimensional connectivity (Euler number/tissue volume) has been determined for the first time in human cancellous bone and shown to correlate with several two-dimensional histomorphometric indices. The method has the potential for overcoming many of the limitations of current approaches to the study of bone architecture at the microscopic level.

Entities:  

Mesh:

Year:  1989        PMID: 2718776     DOI: 10.1002/jbmr.5650040103

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  157 in total

Review 1.  If bone is the answer, then what is the question?

Authors:  R Huiskes
Journal:  J Anat       Date:  2000-08       Impact factor: 2.610

Review 2.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

3.  Evaluation of trabecular microarchitecture in nonosteoporotic postmenopausal women with and without fracture.

Authors:  Richard Kijowski; Michael Tuite; Diane Kruger; Alejandro Munoz Del Rio; Michael Kleerekoper; Neil Binkley
Journal:  J Bone Miner Res       Date:  2012-07       Impact factor: 6.741

4.  Vertebral body bone strength: the contribution of individual trabecular element morphology.

Authors:  I H Parkinson; A Badiei; M Stauber; J Codrington; R Müller; N L Fazzalari
Journal:  Osteoporos Int       Date:  2011-11-16       Impact factor: 4.507

5.  Three-dimensional observation of the mouse embryo by micro-computed tomography: Meckel's cartilage, otocyst, and/or muscle of tongue.

Authors:  Hidekazu Aoyagi; Shin-ichi Iwasaki; Hideki Yoshizawa; Kohzo Tsuchikawa
Journal:  Odontology       Date:  2011-10-04       Impact factor: 2.634

6.  Enhanced cell ingrowth and proliferation through three-dimensional nanocomposite scaffolds with controlled pore structures.

Authors:  Kee-Won Lee; Shanfeng Wang; Mahrokh Dadsetan; Michael J Yaszemski; Lichun Lu
Journal:  Biomacromolecules       Date:  2010-03-08       Impact factor: 6.988

7.  Three-dimensional texture analysis of cancellous bone cores evaluated at clinical CT resolutions.

Authors:  Chad Showalter; Bradley D Clymer; Bradford Richmond; Kimerly Powell
Journal:  Osteoporos Int       Date:  2005-09-17       Impact factor: 4.507

8.  Implications of resolution and noise for in vivo micro-MRI of trabecular bone.

Authors:  Charles Q Li; Jeremy F Magland; Chamith S Rajapakse; X Edward Guo; X Henry Zhang; Branimir Vasilic; Felix W Wehrli
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

10.  Dissociation of the neuronal regulation of bone mass and energy metabolism by leptin in vivo.

Authors:  Yu Shi; Vijay K Yadav; Nina Suda; X Sherry Liu; X Edward Guo; Martin G Myers; Gerard Karsenty
Journal:  Proc Natl Acad Sci U S A       Date:  2008-12-11       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.