| Literature DB >> 27184606 |
Shogo Arimura1, Yuji Takihara1, Seiji Miyake1, Kentaro Iwasaki1, Makoto Gozawa1, Takehiro Matsumura1, Takeshi Tomomatsu1, Yoshihiro Takamura1, Masaru Inatani1.
Abstract
We compared early postoperative complications between trabeculectomy and Ex-PRESS implantation. Enrolled patients with 39 primary open-angle or 25 exfoliative glaucoma were randomly assigned to receive trabeculectomy (trabeculectomy group) or Ex-PRESS implantation (Ex-PRESS group). Primary outcomes were early postoperative complications, including postoperative anterior chamber inflammation, frequencies of hyphema, flat anterior chamber, choroidal detachment, hypotonic maculopathy, and the change of visual acuity. The postoperative flare values in trabeculectomy group were higher than those in the Ex-PRESS group (overall, P = 0.004; and 10 days, P = 0.02). Hyphema occurred significantly more frequently in the trabeculectomy group (P = 0.0025). There were no significant differences of the other primary outcomes between the two groups. Additionally, duration of anterior chamber opening was significantly shorter in the Ex-PRESS group (P = 0.0002) and the eyes that had iris contact with Ex-PRESS tube had significantly shallower anterior chambers than did the eyes without the iris contact (P = 0.013). The Ex-PRESS implantation prevented early postoperative inflammation and hyphema in the anterior chamber and shortened the duration of anterior chamber opening. Iris contact with the Ex-PRESS tube occurred more frequently in eyes with open-angle glaucoma and shallow anterior chambers.Entities:
Mesh:
Year: 2016 PMID: 27184606 PMCID: PMC4869117 DOI: 10.1038/srep26080
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Diagram of the study design.
Patients who met the inclusion criteria were randomized 1:1 to receive a trabeculectomy or Ex-PRESS implantation. After randomization, one patient in the trabeculectomy group was excluded because the preoperative intraocular pressure (IOP) was less than 18 mmHg.
Demographic characteristics.
| Characteristic | Trabeculectomy | Ex-PRESS | |
|---|---|---|---|
| n = 32 | n = 32 | ||
| Age, y | 72.7 ± 9.6 | 70.7 ± 11.4 | 0.47* |
| Sex, Male/Female | 13/19 | 14/18 | 0.80† |
| Side of surgical eye, Right/Left | 17/15 | 14/18 | 0.45† |
| Type | |||
| Primary open-angle glaucoma/Exfoliation glaucoma | 19/13 | 20/12 | 0.80† |
| Number of preoperative medication | 2.7 ± 0.7 | 2.6 ± 0.7 | 0.27* |
| Anterior chamber depth, mm | 2.93 ± 0.45 | 2.94 ± 0.45 | 0.94* |
| Preoperative intraocular pressure, mmHg | 27.9 ± 10.7 | 27.2 ± 8.5 | 0.94* |
| Preoperative visual acuity, logMAR | 0.33 ± 0.48 | 0.40 ± 0.43 | 0.28* |
| Axial length, mm | 23.6 ± 1.6 | 24.2 ± 1.5 | 0.13* |
| Corneal thickness, mm | 0.51 ± 0.05 | 0.51 ± 0.04 | 0.95* |
| Automated perimetry program 24-2 | |||
| Eyes, No. (%) | 11 (34) | 16 (50) | |
| MD, mean (dB) | −10.2 ± 6.94 | −11.3 ± 5.52 | 0.75* |
| Automated perimetry program 10-2 | |||
| Eyes, No. (%) | 18 (56) | 13 (41) | |
| MD, mean (dB) | −22.0 ± 7.60 | −22.0 ± 8.96 | 0.81* |
| Fixation loss | |||
| No. (%) | 3 (9) | 3 (9) | 1.00 |
logMAR = logarithm of the minimal angle of resolution, MD = mean deviation.
*Mann-Whitney non-parametric test. (Data are mean values ± standard deviation).
†The Chi-square test.
Figure 2Changes in flare value after a trabeculectomy or Ex-PRESS implantation.
There were significant differences between the groups 10 days after the surgery (*P = 0.04). The data (mean ± standard error) were compared with the Mann-Whitney test with Bonferroni correction. Pre-ope.; pre-operation.
Early postoperative complications.
| Type of complication | Trabeculectomy n = 32 | Ex-PRESS n = 32 | |
|---|---|---|---|
| Hyphema (%) | 8 (25.0%) | 0 (0%) | 0.0025* |
| Flat anterior chamber (%) | 5 (15.6%) | 3 (9.4%) | 0.45 |
| Choroidal detachment (%) | 4 (12.5%) | 6 (18.8%) | 0.49 |
| Hypotonic maculopathy (%) | 1 (3.1%) | 1 (3.1%) | 1.00 |
The Chi-square test test.
*Statistically significant (P < 0.05).
Intraocular pressure in the trabeculectomy and the Ex-PRESS groups.
| Time Point | Trabeculectomy Intraocular pressure (mmHg) n = 32 | Ex-PRESS Intraocular pressure (mmHg) n = 32 | |
|---|---|---|---|
| Preoperatively | 27.9 ± 10.7 | 27.2 ± 8.5 | 0.94 |
| 1 day | 12.2 ± 6.1 | 10.4 ± 7.9 | 0.15 |
| 3 day | 10.8 ± 5.1 | 9.4 ± 5.9 | 0.28 |
| 7 day | 8.8 ± 3.4 | 7.5 ± 3.3 | 0.11 |
| 10 day | 9.5 ± 3.4 | 8.3 ± 3.3 | 0.08 |
| 1 month | 13.3 ± 4.8 | 15.8 ± 7.7 | 0.40 |
| 3 month | 13.4 ± 3.8 | 14.7 ± 6.0 | 0.48 |
Mann-Whitney non-parametric test (Data are mean values ± standard deviation).
Figure 3The difference in the anterior chamber depth in eyes with or without iris contact with the Ex-PRESS tube.
The data (mean ± standard deviation) were compared with the Mann-Whitney non-parametric test.