Literature DB >> 27177545

Design and evaluation of a ubiquitous chest-worn cardiopulmonary monitoring system for healthcare application: a pilot study.

Jiewen Zheng1, Congying Ha2, Zhengbo Zhang3.   

Abstract

Ambulatory recording of physiological data will provide us deep insight into the physical condition of patients and athletes, and assessing treatment effects and training performances. This study presents a miniature wearable cardiopulmonary monitoring system called "Smart Chest Strap," which consists of an elastic band worn around the user's chest with integrated sensors, a physiological signals acquisition unit, and a mobile phone. The physiological signals including electrocardiogram, respiratory inductance plethysmograph, and accelerations (ACC) are sampled, digitalized, stored, and simultaneously transmitted to a mobile phone via Bluetooth. A medical validation test with participants performing discontinuous incremental treadmill (0-12 km/h) exercise was conducted. The results indicate nearly perfect correlations (0.999, 0.996, 0.994), small mean bias (0.60 BPM, 0.51 BPM, 0.05 g), and narrow limits of agreement (±2.90 BPM, ±1.81 BPM, ±0.09 g) for heart rate (HR), breathing rate (BR), and ACC represented as vector magnitude units (VMUs). There is a general trend of decrease in accuracy, precision, and correlation for HR, BR, and VMU as velocity increases, but these validity statistics are all within acceptable error limits and clinically accepted. The findings demonstrate that the Smart Chest Strap is valid and will have wider applications in healthcare, sports, and scientific research areas.

Entities:  

Keywords:  Ambulatory physiological monitoring; Cardiopulmonary; Smart Chest Strap; Ubiquitous; VMU

Mesh:

Year:  2016        PMID: 27177545     DOI: 10.1007/s11517-016-1518-5

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  AC-coupled front-end for biopotential measurements.

Authors:  Enrique Mario Spinelli; Ramon Pallàs-Areny; Miguel Angel Mayosky
Journal:  IEEE Trans Biomed Eng       Date:  2003-03       Impact factor: 4.538

Review 3.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

4.  Analysis of first-derivative based QRS detection algorithms.

Authors:  Natalia M Arzeno; Zhi-De Deng; Chi-Sang Poon
Journal:  IEEE Trans Biomed Eng       Date:  2008-02       Impact factor: 4.538

5.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

6.  Validation of the Fitbit One activity monitor device during treadmill walking.

Authors:  Judit Takacs; Courtney L Pollock; Jerrad R Guenther; Mohammadreza Bahar; Christopher Napier; Michael A Hunt
Journal:  J Sci Med Sport       Date:  2013-10-31       Impact factor: 4.319

7.  Smart Vest: wearable multi-parameter remote physiological monitoring system.

Authors:  P S Pandian; K Mohanavelu; K P Safeer; T M Kotresh; D T Shakunthala; Parvati Gopal; V C Padaki
Journal:  Med Eng Phys       Date:  2007-09-14       Impact factor: 2.242

8.  Calculating correlation coefficients with repeated observations: Part 1--Correlation within subjects.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1995-02-18

9.  Validity and reliability of multiparameter physiological measurements recorded by the Equivital LifeMonitor during activities of various intensities.

Authors:  Yan Liu; Shai H Zhu; Guo H Wang; Fei Ye; Peng Z Li
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

10.  Validation of the RT3 triaxial accelerometer for the assessment of physical activity.

Authors:  Ann V Rowlands; Philip W M Thomas; Roger G Eston; Rodney Topping
Journal:  Med Sci Sports Exerc       Date:  2004-03       Impact factor: 5.411

View more
  3 in total

Review 1.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

2.  Scoping Review of Healthcare Literature on Mobile, Wearable, and Textile Sensing Technology for Continuous Monitoring.

Authors:  N Hernandez; L Castro; J Medina-Quero; J Favela; L Michan; W Ben Mortenson
Journal:  J Healthc Inform Res       Date:  2021-02-01

3.  Big data analytics for preventive medicine.

Authors:  Muhammad Imran Razzak; Muhammad Imran; Guandong Xu
Journal:  Neural Comput Appl       Date:  2019-03-16       Impact factor: 5.102

  3 in total