Literature DB >> 24268570

Validation of the Fitbit One activity monitor device during treadmill walking.

Judit Takacs1, Courtney L Pollock1, Jerrad R Guenther1, Mohammadreza Bahar1, Christopher Napier1, Michael A Hunt2.   

Abstract

OBJECTIVES: In order to quantify the effects of physical activity such as walking on chronic disease, accurate measurement of physical activity is needed. The objective of this study was to determine the validity and reliability of a new activity monitor, the Fitbit One, in a population of healthy adults.
DESIGN: Cross-sectional study.
METHODS: Thirty healthy adults ambulated at 5 different speeds (0.90, 1.12, 1.33, 1.54, 1.78 m/s) on a treadmill while wearing three Fitbit One activity monitors (two on the hips and one in the pocket). The order of each speed condition was randomized. Fitbit One step count output was compared to observer counts and distance output was compared to the calibrated treadmill output. Two-way repeated measures ANOVA, concordance correlation coefficients, and Bland and Altman plots were used to assess validity and intra-class correlation coefficients (ICC) were used to assess reliability.
RESULTS: No significant differences were noted between Fitbit One step count outputs and observer counts, and concordance was substantial (0.97-1.00). Inter-device reliability of the step count was high for all walking speeds (ICC ≥ 0.95). Percent relative error was less than 1.3%. The distance output of the Fitbit One activity monitors was significantly different from the criterion values for each monitor at all speeds (P<0.001) and exhibited poor concordance (0.0-0.05). Inter-device reliability was excellent for all treadmill speeds (ICC ≥ 0.90). Percent relative error was high (up to 39.6%).
CONCLUSIONS: The Fitbit One activity monitors are valid and reliable devices for measuring step counts in healthy young adults. The distance output of the monitors is inaccurate and should be noted with caution.
Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Keywords:  Health; Pedometer; Physical activity; Reliability and validity; Walking

Mesh:

Year:  2013        PMID: 24268570     DOI: 10.1016/j.jsams.2013.10.241

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  99 in total

1.  Wearable Sensor/Device (Fitbit One) and SMS Text-Messaging Prompts to Increase Physical Activity in Overweight and Obese Adults: A Randomized Controlled Trial.

Authors:  Julie B Wang; Lisa A Cadmus-Bertram; Loki Natarajan; Martha M White; Hala Madanat; Jeanne F Nichols; Guadalupe X Ayala; John P Pierce
Journal:  Telemed J E Health       Date:  2015-06-02       Impact factor: 3.536

2.  Validation of a Self-Monitoring Tool for Use in Exercise Therapy.

Authors:  Camilla S Powierza; Michael D Clark; Jaime M Hughes; Kevin A Carneiro; Jason P Mihalik
Journal:  PM R       Date:  2017-04-09       Impact factor: 2.298

3.  GPS-Based Exposure to Greenness and Walkability and Accelerometry-Based Physical Activity.

Authors:  Peter James; Jaime E Hart; J Aaron Hipp; Jonathan A Mitchell; Jacqueline Kerr; Philip M Hurvitz; Karen Glanz; Francine Laden
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2017-02-14       Impact factor: 4.254

Review 4.  The Value of Patient Reported Outcomes and Other Patient-Generated Health Data in Clinical Hematology.

Authors:  Hemant S Murthy; William A Wood
Journal:  Curr Hematol Malig Rep       Date:  2015-09       Impact factor: 3.952

Review 5.  How consumer physical activity monitors could transform human physiology research.

Authors:  Stephen P Wright; Tyish S Hall Brown; Scott R Collier; Kathryn Sandberg
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2017-01-04       Impact factor: 3.619

6.  Dose and timing of text messages for increasing physical activity among pregnant women: a randomized controlled trial.

Authors:  Jennifer L Huberty; Matthew P Buman; Jenn A Leiferman; Jessica Bushar; Eric B Hekler; Marc A Adams
Journal:  Transl Behav Med       Date:  2017-06       Impact factor: 3.046

Review 7.  The use of ambulatory assessment in smoking cessation.

Authors:  Christine Vinci; Aaron Haslam; Cho Y Lam; Santosh Kumar; David W Wetter
Journal:  Addict Behav       Date:  2018-02-03       Impact factor: 3.913

8.  "Spatial Energetics": Integrating Data From GPS, Accelerometry, and GIS to Address Obesity and Inactivity.

Authors:  Peter James; Marta Jankowska; Christine Marx; Jaime E Hart; David Berrigan; Jacqueline Kerr; Philip M Hurvitz; J Aaron Hipp; Francine Laden
Journal:  Am J Prev Med       Date:  2016-08-12       Impact factor: 5.043

9.  Assessing the Effects of Interpersonal and Intrapersonal Behavior Change Strategies on Physical Activity in Older Adults: a Factorial Experiment.

Authors:  Siobhan K McMahon; Beth Lewis; J Michael Oakes; Jean F Wyman; Weihua Guan; Alexander J Rothman
Journal:  Ann Behav Med       Date:  2017-06

10.  "Stepping Up" Activity Poststroke: Ankle-Positioned Accelerometer Can Accurately Record Steps During Slow Walking.

Authors:  Tara D Klassen; Lisa A Simpson; Shannon B Lim; Dennis R Louie; Beena Parappilly; Brodie M Sakakibara; Dominik Zbogar; Janice J Eng
Journal:  Phys Ther       Date:  2015-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.