Literature DB >> 27171019

Longitudinal Monitoring of Hepatic Blood Flow before and after TIPS by Using 4D-Flow MR Imaging.

Peter Bannas1, Alejandro Roldán-Alzate1, Kevin M Johnson1, Michael A Woods1, Orhan Ozkan1, Utaroh Motosugi1, Oliver Wieben1, Scott B Reeder1, Harald Kramer1.   

Abstract

Purpose To demonstrate the feasibility of four-dimensional (4D)-flow magnetic resonance (MR) imaging for noninvasive longitudinal hemodynamic monitoring of hepatic blood flow before and after transjugular intrahepatic portosystemic shunt (TIPS) placement. Materials and Methods The institutional review board approved this prospective Health Insurance Portability and Accountability Act compliant study with written informed consent. Four-dimensional-flow MR imaging was performed in seven patients with portal hypertension and refractory ascites before and 2 and 12 weeks after TIPS placement by using a time-resolved three-dimensional radial phase-contrast acquisition. Flow and peak velocity measurements were obtained in the superior mesenteric vein (SMV), splenic vein (SV), portal vein (PV), and the TIPS. Flow volumes and peak velocities in each vessel, as well as the ratio of in-stent to PV flow, were compared before and after TIPS placement by using analysis of variance. Results Flow volumes significantly increased in the SMV (0.24 L/min; 95% confidence interval [CI]: 0.07, 0.41), SV (0.31 L/min; 95% CI: 0.07, 0.54), and PV (0.88 L/min; 95% CI: 0.06, 1.70) after TIPS placement (all P < .05), with no significant difference between the first and second post-TIPS placement acquisitions (all P > .11). Ascites resolved in six of seven patients. In those with resolved ascites, the TIPS-to-PV flow ratio was 0.8 ± 0.2 and 0.9 ± 0.2 at the two post-TIPS time points, respectively, while the observed ratios were 4.6 and 4.3 in the patient with refractory ascites at the two post-TIPS time points, respectively. In this patient, 4D-flow MR imaging demonstrated arterio-portal-venous shunting, with draining into the TIPS. Conclusion Four-dimensional-flow MR imaging is feasible for noninvasive longitudinal hemodynamic monitoring of hepatic blood flow before and after TIPS placement. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27171019      PMCID: PMC5069148          DOI: 10.1148/radiol.2016152247

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  31 in total

Review 1.  Complications of cirrhosis. I. Portal hypertension.

Authors:  J Bosch; J C García-Pagán
Journal:  J Hepatol       Date:  2000       Impact factor: 25.083

2.  Guidelines on the management of ascites in cirrhosis.

Authors:  K P Moore; G P Aithal
Journal:  Gut       Date:  2006-10       Impact factor: 23.059

3.  Portal flow and arterioportal shunting after transjugular intrahepatic portosystemic shunt creation.

Authors:  Maxim Itkin; Scott O Trerotola; S William Stavropoulos; Aalpen Patel; Jeffrey I Mondschein; Michael C Soulen; Catherine M Tuite; Richard D Shlansky-Goldberg; Thomas W Faust; K Rajender Reddy; Jeffrey A Solomon; Timothy W I Clark
Journal:  J Vasc Interv Radiol       Date:  2006-01       Impact factor: 3.464

4.  The Role of Transjugular Intrahepatic Portosystemic Shunt (TIPS) in the Management of Portal Hypertension: update 2009.

Authors:  Thomas D Boyer; Ziv J Haskal
Journal:  Hepatology       Date:  2010-01       Impact factor: 17.425

5.  Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow.

Authors:  Jingfeng Jiang; Charles Strother; Kevin Johnson; Sara Baker; Dan Consigny; Oliver Wieben; James Zagzebski
Journal:  Phys Med Biol       Date:  2011-02-23       Impact factor: 3.609

6.  Semiautomated method for noise reduction and background phase error correction in MR phase velocity data.

Authors:  P G Walker; G B Cranney; M B Scheidegger; G Waseleski; G M Pohost; A P Yoganathan
Journal:  J Magn Reson Imaging       Date:  1993 May-Jun       Impact factor: 4.813

7.  In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension.

Authors:  Alejandro Roldán-Alzate; Alex Frydrychowicz; Eric Niespodzany; Ben R Landgraf; Kevin M Johnson; Oliver Wieben; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-11-12       Impact factor: 4.813

8.  Quantification of thoracic blood flow using volumetric magnetic resonance imaging with radial velocity encoding: in vivo validation.

Authors:  Alex Frydrychowicz; Oliver Wieben; Eric Niespodzany; Scott B Reeder; Kevin M Johnson; Christopher J François
Journal:  Invest Radiol       Date:  2013-12       Impact factor: 6.016

Review 9.  Predictors of hepatic encephalopathy after transjugular intrahepatic portosystemic shunt in cirrhotic patients: a systematic review.

Authors:  Ming Bai; Xingshun Qi; Zhiping Yang; Zhanxin Yin; Yongzhan Nie; Shanshan Yuan; Kaichun Wu; Guohong Han; Daiming Fan
Journal:  J Gastroenterol Hepatol       Date:  2011-06       Impact factor: 4.029

10.  Volumetric blood flow in transjugular intrahepatic portosystemic shunt revision using 3-dimensional Doppler sonography.

Authors:  Stephen Z Pinter; Jonathan M Rubin; Oliver D Kripfgans; Paula M Novelli; Mario Vargas-Vila; Anne L Hall; J Brian Fowlkes
Journal:  J Ultrasound Med       Date:  2015-02       Impact factor: 2.153

View more
  10 in total

1.  The Feasibility of Using Volumetric Phase-Contrast MR Imaging (4D Flow) to Assess for Transjugular Intrahepatic Portosystemic Shunt Dysfunction.

Authors:  Joseph W Owen; Nael E Saad; Glenn Foster; Kathryn J Fowler
Journal:  J Vasc Interv Radiol       Date:  2018-11-03       Impact factor: 3.464

Review 2.  Noninvasive imaging assessment of portal hypertension.

Authors:  Paul Kennedy; Octavia Bane; Stefanie J Hectors; Aaron Fischman; Thomas Schiano; Sara Lewis; Bachir Taouli
Journal:  Abdom Radiol (NY)       Date:  2020-09-14

3.  Hemodynamic measurements with an abdominal 4D flow MRI sequence with spiral sampling and compressed sensing in patients with chronic liver disease.

Authors:  Octavia Bane; Steven Peti; Mathilde Wagner; Stefanie Hectors; Hadrien Dyvorne; Michael Markl; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2018-10-14       Impact factor: 4.813

4.  Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.

Authors:  A Frydrychowicz; A Roldan-Alzate; E Winslow; D Consigny; C A Campo; U Motosugi; K M Johnson; O Wieben; S B Reeder
Journal:  Eur Radiol       Date:  2017-06-27       Impact factor: 5.315

5.  Four-dimensional Flow MRI as a Marker for Risk Stratification of Gastroesophageal Varices in Patients with Liver Cirrhosis.

Authors:  Utaroh Motosugi; Alejandro Roldán-Alzate; Peter Bannas; Adnan Said; Sean Kelly; Ryan Zea; Oliver Wieben; Scott B Reeder
Journal:  Radiology       Date:  2018-10-16       Impact factor: 11.105

6.  Automatic measurement plane placement for 4D Flow MRI of the great vessels using deep learning.

Authors:  Philip A Corrado; Daniel P Seiter; Oliver Wieben
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-17       Impact factor: 2.924

Review 7.  4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications.

Authors:  Ryota Hyodo; Yasuo Takehara; Shinji Naganawa
Journal:  Radiol Med       Date:  2022-09-19       Impact factor: 6.313

Review 8.  Abdominal applications of quantitative 4D flow MRI.

Authors:  Thekla H Oechtering; Grant S Roberts; Nikolaos Panagiotopoulos; Oliver Wieben; Alejandro Roldán-Alzate; Scott B Reeder
Journal:  Abdom Radiol (NY)       Date:  2021-11-27

Review 9.  Four-Dimensional Flow MRI of Abdominal Veins: A Systematic Review.

Authors:  Simon O Haarbye; Michael B Nielsen; Adam E Hansen; Carsten A Lauridsen
Journal:  Diagnostics (Basel)       Date:  2021-04-24

10.  Visualization of flow dynamics in the portal circulation using 320-detector-row computed tomography: a feasibility study.

Authors:  Ken Kageyama; Akira Yamamoto; Atsushi Jogo; Shinichiro Izuta; Daisuke Himoto; Akihiko Kakimi; Etsuji Sohgawa; Yukio Miki
Journal:  Eur Radiol Exp       Date:  2021-01-12
  10 in total