Literature DB >> 30396843

The Feasibility of Using Volumetric Phase-Contrast MR Imaging (4D Flow) to Assess for Transjugular Intrahepatic Portosystemic Shunt Dysfunction.

Joseph W Owen1, Nael E Saad2, Glenn Foster3, Kathryn J Fowler3.   

Abstract

PURPOSE: To demonstrate the feasibility of detecting patency, stenosis, or occlusion of transjugular intrahepatic portosystemic shunt (TIPS) with four-dimensional (4D) flow MR imaging.
MATERIALS AND METHODS: Sequential adult patients with TIPS were eligible for enrollment. Volumetric phase-contrast sequence was used to image TIPS. Particle tracing cine images were used for qualitative assessment of stenosis. TIPS was segmented to generate quantitative data sets of peak velocity. Segmentation and quantitative measurement of flow throughout an entire TIPS defined technical success. Doppler US was used for comparison. Venography, when available, and 6-month clinical follow-up were used as reference standards.
RESULTS: 4D flow MR imaging was performed in 23 patient encounters and was technically successful in 16/23 (69.6%) encounters. Three cases demonstrated both focal turbulence and abnormal velocities (> 190 cm/s or < 90 cm/s) on 4D flow and had venography-confirmed stenosis (true-positive cases). Seven cases had normal velocities and no turbulence on 4D flow, and all were confirmed negative with clinical follow-up or venography (true-negative cases). Six cases had discordant 4D flow results, with abnormal velocities but no turbulence or focal turbulence but normal velocities. All 6 discordant cases had no evidence of dysfunction during 6-month follow-up.
CONCLUSION: 4D flow MR imaging can detect TIPS patency and stenosis, but further investigation is required before it can be used to assess for TIPS dysfunction.
Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30396843      PMCID: PMC6951427          DOI: 10.1016/j.jvir.2018.07.022

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  19 in total

1.  Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses.

Authors:  V A Feldstein; M D Patel; J M LaBerge
Journal:  Radiology       Date:  1996-10       Impact factor: 11.105

2.  Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction.

Authors:  R Y Kanterman; M D Darcy; W D Middleton; K M Sterling; S A Teefey; T K Pilgram
Journal:  AJR Am J Roentgenol       Date:  1997-02       Impact factor: 3.959

Review 3.  Evaluation and management of transjugular intrahepatic portosystemic shunts.

Authors:  Michael Darcy
Journal:  AJR Am J Roentgenol       Date:  2012-10       Impact factor: 3.959

4.  Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity.

Authors:  W K Chong; T A Malisch; M J Mazer; C D Lind; J A Worrell; W O Richards
Journal:  Radiology       Date:  1993-12       Impact factor: 11.105

5.  k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress.

Authors:  Susanne Schnell; Michael Markl; Pegah Entezari; Riti J Mahadewia; Edouard Semaan; Zoran Stankovic; Jeremy Collins; James Carr; Bernd Jung
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

6.  Role of ultrasound surveillance of transjugular intrahepatic portosystemic shunts in the covered stent era.

Authors:  Caitlin E Carr; Catherine M Tuite; Michael C Soulen; Richard D Shlansky-Goldberg; Timothy W I Clark; Jeffrey I Mondschein; Andrew Kwak; Aalpen A Patel; Beverly G Coleman; Scott O Trerotola
Journal:  J Vasc Interv Radiol       Date:  2006-08       Impact factor: 3.464

7.  Results of a retrospective multicenter trial of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation.

Authors:  Jean-Pierre M Charon; Fida H Alaeddin; Sheena A Pimpalwar; Dominic M Fay; Simon P Olliff; Ralph W Jackson; Richard D Edwards; Iain R Robertson; John D Rose; Jonathan G Moss
Journal:  J Vasc Interv Radiol       Date:  2004-11       Impact factor: 3.464

8.  Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography.

Authors:  G D Dodd; A B Zajko; P D Orons; M S Martin; L S Eichner; L A Santaguida
Journal:  AJR Am J Roentgenol       Date:  1995-05       Impact factor: 3.959

9.  Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures.

Authors:  Geert Maleux; Frederik Nevens; Alexander Wilmer; Sam Heye; Chris Verslype; Maria Thijs; Guy Wilms
Journal:  Eur Radiol       Date:  2004-06-25       Impact factor: 5.315

10.  Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a Doppler/manometric correlative study.

Authors:  M Lafortune; J P Martinet; A Denys; H Patriquin; M Dauzat; M P Dufresne; L Colombato; G Pomier-Layrargues
Journal:  AJR Am J Roentgenol       Date:  1995-04       Impact factor: 3.959

View more
  6 in total

Review 1.  4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications.

Authors:  Ryota Hyodo; Yasuo Takehara; Shinji Naganawa
Journal:  Radiol Med       Date:  2022-09-19       Impact factor: 6.313

Review 2.  Abdominal applications of quantitative 4D flow MRI.

Authors:  Thekla H Oechtering; Grant S Roberts; Nikolaos Panagiotopoulos; Oliver Wieben; Alejandro Roldán-Alzate; Scott B Reeder
Journal:  Abdom Radiol (NY)       Date:  2021-11-27

3.  4D Flow MR Imaging to Improve Microwave Ablation Prediction Models: A Feasibility Study in an In Vivo Porcine Liver.

Authors:  Jason Chiang; Michael Loecher; Kevin Moulin; M Franca Meloni; Steven S Raman; Justin P McWilliams; Daniel B Ennis; Edward W Lee
Journal:  J Vasc Interv Radiol       Date:  2020-03-13       Impact factor: 3.464

Review 4.  Four-Dimensional Flow MRI of Abdominal Veins: A Systematic Review.

Authors:  Simon O Haarbye; Michael B Nielsen; Adam E Hansen; Carsten A Lauridsen
Journal:  Diagnostics (Basel)       Date:  2021-04-24

5.  Quantification of the Hemodynamic Changes of Cirrhosis with Free-Breathing Self-Navigated MRI.

Authors:  Ryan L Brunsing; Dustin Brown; Hashem Almahoud; Yuko Kono; Rohit Loomba; Irene Vodkin; Claude B Sirlin; Marcus T Alley; Shreyas S Vasanawala; Albert Hsiao
Journal:  J Magn Reson Imaging       Date:  2021-02-16       Impact factor: 5.119

6.  A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination.

Authors:  Jiacheng Liu; Jie Meng; Chen Zhou; Qin Shi; Chongtu Yang; Jinqiang Ma; Manman Chen; Bin Xiong
Journal:  J Interv Med       Date:  2020-10-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.