Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.

David L Levitt1, Kristi D Silver1, Elias K Spanakis1,2.   

Abstract

Continuous glucose monitoring (CGM) is commonly used in the outpatient setting to improve diabetes management. CGM can provide real-time glucose trends, detecting hyperglycemia and hypoglycemia before the onset of clinical symptoms. In 2011, at the time the Endocrine Society CGM guidelines were published, the society did not recommend inpatient CGM as its efficacy and safety were unknown. While many studies have subsequently evaluated inpatient CGM accuracy and reliability, glycemic outcome studies have not been widely published. In the non-ICU setting, investigational CGM studies have commonly blinded providers and patients to glucose data. Retrospective review of the glucose data reflects increased hypoglycemia detection with CGM. In the ICU setting, data are inconsistent whether CGM can improve glycemic outcomes. Studies have not focused on hospitalized patients with type 1 diabetes mellitus, the population most likely to benefit from inpatient CGM. This article reviews inpatient CGM glycemic outcomes in the non-ICU and ICU setting.

Entities:  

Keywords:  CGM; continuous glucose monitoring; hospital; inpatient; type 1 diabetes; type 2 diabetes

Mesh:

Substances:

Year:  2017        PMID: 28290224      PMCID: PMC5950986          DOI: 10.1177/1932296817698499

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  66 in total

1.  Prediction of glucose concentration in post-cardiothoracic surgery patients using continuous glucose monitoring.

Authors:  Lukas Schaupp; Johannes Plank; Gerd Köhler; Roland Schaller; Christopher Wrighton; Martin Ellmerer; Thomas R Pieber
Journal:  Diabetes Technol Ther       Date:  2011-02       Impact factor: 6.118

2.  Continuous Glucose Monitoring Use in Hospitalized Patients.

Authors:  Kathleen M Dungan
Journal:  Diabetes Technol Ther       Date:  2015-05-15       Impact factor: 6.118

3.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

Review 4.  Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.

Authors:  Jeffrey I Joseph; Marc C Torjman; Paul J Strasma
Journal:  J Diabetes Sci Technol       Date:  2015-06-15

Review 5.  Glucose Control in the ICU: A Continuing Story.

Authors:  Jean-Charles Preiser; J Geoffrey Chase; Roman Hovorka; Jeffrey I Joseph; James S Krinsley; Christophe De Block; Thomas Desaive; Luc Foubert; Pierre Kalfon; Ulrike Pielmeier; Tom Van Herpe; Jan Wernerman
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

6.  Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

Authors:  D Ballesteros; Ó Martínez; R Blancas Gómez-Casero; C Martín Parra; B López Matamala; B Estébanez; M Chana
Journal:  Med Intensiva       Date:  2014-12-12       Impact factor: 2.491

7.  Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit.

Authors:  Philip A Goldberg; Mark D Siegel; Robert S Sherwin; Joshua I Halickman; Michelle Lee; Valerie A Bailey; Sandy L Lee; James D Dziura; Silvio E Inzucchi
Journal:  Diabetes Care       Date:  2004-02       Impact factor: 19.112

Review 8.  Economic costs of diabetes in the U.S. In 2007.

Authors: 
Journal:  Diabetes Care       Date:  2008-03       Impact factor: 19.112

9.  Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial.

Authors:  Tobias Wollersheim; Lilian Jo Engelhardt; Jeanne Pachulla; Rudolf Moergeli; Susanne Koch; Claudia Spies; Michael Hiesmayr; Steffen Weber-Carstens
Journal:  Ann Intensive Care       Date:  2016-07-21       Impact factor: 6.925

10.  Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial.

Authors:  Ulrike Holzinger; Joanna Warszawska; Reinhard Kitzberger; Marlene Wewalka; Wolfgang Miehsler; Harald Herkner; Christian Madl
Journal:  Diabetes Care       Date:  2009-12-10       Impact factor: 19.112

View more
  13 in total

Review 1.  Designing the Glucose Telemetry for Hospital Management: From Bedside to the Nursing Station.

Authors:  Medha Satyarengga; Tariq Siddiqui; Elias K Spanakis
Journal:  Curr Diab Rep       Date:  2018-08-29       Impact factor: 4.810

2.  Hypoglycemia Incidence and Factors Associated in a Cohort of Patients With Type 2 Diabetes Hospitalized in General Ward Treated With Basal Bolus Insulin Regimen Assessed by Continuous Glucose Monitoring.

Authors:  Ana María Gómez; Angélica Imitola Madero; Diana Cristina Henao Carrillo; Martín Rondón; Oscar Mauricio Muñoz; Maria Alejandra Robledo; Martín Rebolledo; Maira García Jaramillo; Fabian León Vargas; Guillermo Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2019-01-24

3.  Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus.

Authors:  David L Levitt; Elias K Spanakis; Kathleen A Ryan; Kristi D Silver
Journal:  Diabetes Technol Ther       Date:  2018-01-02       Impact factor: 6.118

4.  The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System.

Authors:  Elias K Spanakis; David L Levitt; Tariq Siddiqui; Lakshmi G Singh; Lillian Pinault; John Sorkin; Guillermo E Umpierrez; Jeffrey C Fink
Journal:  J Diabetes Sci Technol       Date:  2017-12-13

5.  Glucose Management Technologies for the Critically Ill.

Authors:  Pedro D Salinas; Carlos E Mendez
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

6.  Advancing the Use of CGM Devices in a Non-ICU Setting.

Authors:  Meng Wang; Lakshmi G Singh; Elias K Spanakis
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

7.  Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.

Authors:  Laura A Scrimgeour; Brittany A Potz; Frank W Sellke; M Ruhul Abid
Journal:  Clin Med Res (N Y)       Date:  2017-11-24

Review 8.  A systematic review on clinical implication of continuous glucose monitoring in diabetes management.

Authors:  Anam Azhar; Syed W Gillani; Ghasna Mohiuddin; Rukhsar A Majeed
Journal:  J Pharm Bioallied Sci       Date:  2020-04-10

Review 9.  Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.

Authors:  Guillermo E Umpierrez; David C Klonoff
Journal:  Diabetes Care       Date:  2018-06-23       Impact factor: 19.112

10.  Reducing Inpatient Hypoglycemia in the General Wards Using Real-time Continuous Glucose Monitoring: The Glucose Telemetry System, a Randomized Clinical Trial.

Authors:  Lakshmi G Singh; Medha Satyarengga; Isabel Marcano; William H Scott; Lillian F Pinault; Zhaoyong Feng; John D Sorkin; Guillermo E Umpierrez; Elias K Spanakis
Journal:  Diabetes Care       Date:  2020-08-05       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.