Literature DB >> 27161022

Adaptive windowing in contrast-enhanced intravascular ultrasound imaging.

Brooks D Lindsey1, K Heath Martin2, Xiaoning Jiang3, Paul A Dayton4.   

Abstract

Intravascular ultrasound (IVUS) is one of the most commonly-used interventional imaging techniques and has seen recent innovations which attempt to characterize the risk posed by atherosclerotic plaques. One such development is the use of microbubble contrast agents to image vasa vasorum, fine vessels which supply oxygen and nutrients to the walls of coronary arteries and typically have diameters less than 200μm. The degree of vasa vasorum neovascularization within plaques is positively correlated with plaque vulnerability. Having recently presented a prototype dual-frequency transducer for contrast agent-specific intravascular imaging, here we describe signal processing approaches based on minimum variance (MV) beamforming and the phase coherence factor (PCF) for improving the spatial resolution and contrast-to-tissue ratio (CTR) in IVUS imaging. These approaches are examined through simulations, phantom studies, ex vivo studies in porcine arteries, and in vivo studies in chicken embryos. In phantom studies, PCF processing improved CTR by a mean of 4.2dB, while combined MV and PCF processing improved spatial resolution by 41.7%. Improvements of 2.2dB in CTR and 37.2% in resolution were observed in vivo. Applying these processing strategies can enhance image quality in conventional B-mode IVUS or in contrast-enhanced IVUS, where signal-to-noise ratio is relatively low and resolution is at a premium.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Adaptive beamforming; Contrast-enhanced ultrasound; High frequency ultrasound; Intravascular ultrasound; Phase coherence factor; Superharmonic

Mesh:

Substances:

Year:  2016        PMID: 27161022      PMCID: PMC4899141          DOI: 10.1016/j.ultras.2016.04.022

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  54 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

2.  Coronary plaque classification with intravascular ultrasound radiofrequency data analysis.

Authors:  Anuja Nair; Barry D Kuban; E Murat Tuzcu; Paul Schoenhagen; Steven E Nissen; D Geoffrey Vince
Journal:  Circulation       Date:  2002-10-22       Impact factor: 29.690

3.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

4.  Broadband minimum variance beamforming for ultrasound imaging.

Authors:  Iben Kraglund Holfort; Fredrik Gran; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-02       Impact factor: 2.725

5.  Contrast enhancement and robustness improvement of adaptive ultrasound imaging using forward-backward minimum variance beamforming.

Authors:  Babak Mohammadzadeh Asl; Ali Mahloojifar
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-04       Impact factor: 2.725

6.  A novel dual-frequency imaging method for intravascular ultrasound applications.

Authors:  Weibao Qiu; Yan Chen; Chi-Man Wong; Baoqiang Liu; Jiyan Dai; Hairong Zheng
Journal:  Ultrasonics       Date:  2014-10-16       Impact factor: 2.890

7.  A series of normal stages in the development of the chick embryo.

Authors:  V HAMBURGER; H L HAMILTON
Journal:  J Morphol       Date:  1951-01       Impact factor: 1.804

8.  Familial and diet-induced hypercholesterolemia in swine. Lipid, ApoB, and ApoA-I concentrations and distributions in plasma and lipoprotein subfractions.

Authors:  J O Hasler-Rapacz; T C Nichols; T R Griggs; D A Bellinger; J Rapacz
Journal:  Arterioscler Thromb       Date:  1994-06

9.  Adventitial vasa vasorum in balloon-injured coronary arteries: visualization and quantitation by a microscopic three-dimensional computed tomography technique.

Authors:  H M Kwon; G Sangiorgi; E L Ritman; A Lerman; C McKenna; R Virmani; W D Edwards; D R Holmes; R S Schwartz
Journal:  J Am Coll Cardiol       Date:  1998-12       Impact factor: 24.094

10.  Improved method for ex ovo-cultivation of developing chicken embryos for human stem cell xenografts.

Authors:  Timo Schomann; Firas Qunneis; Darius Widera; Christian Kaltschmidt; Barbara Kaltschmidt
Journal:  Stem Cells Int       Date:  2013-03-11       Impact factor: 5.443

View more
  6 in total

1.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

2.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

3.  High Resolution Ultrasound Superharmonic Perfusion Imaging: In Vivo Feasibility and Quantification of Dynamic Contrast-Enhanced Acoustic Angiography.

Authors:  Brooks D Lindsey; Sarah E Shelton; K Heath Martin; Kathryn A Ozgun; Juan D Rojas; F Stuart Foster; Paul A Dayton
Journal:  Ann Biomed Eng       Date:  2016-11-10       Impact factor: 3.934

4.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

5.  A Robotically Steerable Guidewire With Forward-Viewing Ultrasound: Development of Technology for Minimally-Invasive Imaging.

Authors:  Graham C Collins; Achraj Sarma; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

Review 6.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.