Literature DB >> 25454093

A novel dual-frequency imaging method for intravascular ultrasound applications.

Weibao Qiu1, Yan Chen2, Chi-Man Wong2, Baoqiang Liu1, Jiyan Dai3, Hairong Zheng4.   

Abstract

Intravascular ultrasound (IVUS), which is able to delineate internal structures of vessel wall with fine spatial resolution, has greatly enriched the knowledge of coronary atherosclerosis. A novel dual-frequency imaging method is proposed in this paper for intravascular imaging applications. A probe combined two ultrasonic transducer elements with different center frequencies (36 MHz and 78 MHz) is designed and fabricated with PMN-PT single crystal material. It has the ability to balance both imaging depth and resolution, which are important imaging parameters for clinical test. A dual-channel imaging platform is also proposed for real-time imaging, and this platform has been proven to support programmable processing algorithms, flexible imaging control, and raw RF data acquisition for IVUS applications. Testing results show that the -6 dB axial and lateral imaging resolutions of low-frequency ultrasound are 78 and 132 μm, respectively. In terms of high-frequency ultrasound, axial and lateral resolutions are determined to be as high as 34 and 106 μm. In vitro intravascular imaging on healthy swine aorta is conducted to demonstrate the performance of the dual-frequency imaging method for IVUS applications.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiovascular disease; Dual-channel imaging platform; Dual-frequency imaging; Intravascular ultrasound

Mesh:

Year:  2014        PMID: 25454093     DOI: 10.1016/j.ultras.2014.10.011

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  5 in total

1.  Adaptive windowing in contrast-enhanced intravascular ultrasound imaging.

Authors:  Brooks D Lindsey; K Heath Martin; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasonics       Date:  2016-04-27       Impact factor: 2.890

2.  Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography.

Authors:  Jianguo Ma; K Heath Martin; Yang Li; Paul A Dayton; K Kirk Shung; Qifa Zhou; Xiaoning Jiang
Journal:  Phys Med Biol       Date:  2015-04-09       Impact factor: 3.609

3.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

4.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

Review 5.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.