| Literature DB >> 27138595 |
Michael Schauseil1, Sonja Blöcher2, Andreas Hellak2, Matthias J Roggendorf3, Steffen Stein2, Heike Korbmacher-Steiner2.
Abstract
BACKGROUND: To determine the shear bond strength and adhesive remnant index of a new premixed self-etching primer and adhesive (Tectosan, BonaDent, Germany) for orthodontic appliances in comparison to a reference total-etch system Transbond XT.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27138595 PMCID: PMC4852429 DOI: 10.1186/s13005-016-0117-x
Source DB: PubMed Journal: Head Face Med ISSN: 1746-160X Impact factor: 2.151
Overview of the composition of both test series
| Control group | Experimental group | |
|---|---|---|
| Etching | 37 % phosphoric acid | |
| Bonding | TransbondXT-primer | Tectosan primer |
| Adhesive | TransbondXT-adhesive | Tectosan adhesive |
Fig. 1The SBS was measured using a Zwicki 1120 testing machine
The adhesive remnant index (ARI) was measured for every tooth after debonding
| ARI-Score | Explanation |
|---|---|
| 0 | no adhesive remains on the tooth |
| 1 | less than 50 % of the adhesive remains on the tooth |
| 2 | more than 50 % of the adhesive remains on the tooth |
| 3 | all adhesive remains on the tooth. |
Shear Bond Strenght of both bonding agents did not differ significantly
| Groups | n | mean [MPa] | SD [MPa] | min [MPa] | max [MPa] |
|
|---|---|---|---|---|---|---|
| Total-etch | 16 | 16.59 | 6.82 | 7.03 | 31.38 |
|
| Self-etch | 16 | 15.55 | 5.62 | 10.15 | 29.36 |
Fig. 2Kaplan-Meier survival analysis for both groups. (TB, total-etch system, Transbond XT; Tec, self-etch system, Tectosan)
The adhesive remnant index (ARI) on the teeth surfaces for both bonding agents differed significantly
| ARI-Score | Two-tailed Mann–Whitney- | |||||
|---|---|---|---|---|---|---|
| Groups | 0 | 1 | 2 | 3 | Median | |
| Total-etch | 0 | 7 | 6 | 3 | 2 |
|
| Self-etch | 0 | 13 | 2 | 1 | 1 | |
Fig. 3Microscopic and SEM images revealed not any enamel cracks in both groups. a and a: total-etch system; b and b: self-etch system. a and b show a 10x magnification; a, and b show the SEM counterparts (45x) of the same sample