| Literature DB >> 24578817 |
Parisa Salehi1, Hamidreza Pakshir2, Navid Naseri3, Tahereh Baherimoghaddam4.
Abstract
Background and aims. This in vitro study was designed to evaluate the effect of composite resin types and orthodontic debonding pliers on the amount of adhesive remnants and enamel damages using a novel method of measurement. Materials and methods. 120 extracted human premolars were randomly divided into four groups (n = 30). The standard edgewise metallic brackets were bonded to the teeth with light-cured composite resin "Transbond XT" in the first and second groups, and No-mix composite resin "Unite" in the third and fourth groups. Bracket debonding was carried out with Lift Off Debonding Instrument "LODI" (3M Unitek) in the first and third groups, and with Bracket Removing Pliers (Dentaurum) in the second and forth groups. yStereomicroscopic evaluation was performed by unbiased sterelogy. All teeth were evaluated for the amount of adhesive remnants and the number and length of enamel cracks. The obtained data on each step was analyzed by two-way ANOVA, chi-square, Wilcoxon, and Kruskal-Wallis. Results. Teeth in group 4 had the lowest adhesive remnants on the enamel surface (p < 0.01); and the highest increase in the number of enamel cracks (p < 0.01) among the groups. In addition, groups bonded with Unite showed the highest increase in the length of enamel cracks. Conclusion. Dentaurum debonding pliers with sheer-peel force, when used with the Unite adhesive (group 4), decreased the amount of adhesive remnants on the enamel surface while it increased enamel damages.Entities:
Keywords: Dental debonding; dental enamel; orthodontic adhesive; orthodontic appliance
Year: 2013 PMID: 24578817 PMCID: PMC3935550 DOI: 10.5681/joddd.2013.032
Source DB: PubMed Journal: J Dent Res Dent Clin Dent Prospects ISSN: 2008-210X
a
bTwo-way analysis of adhesive remnant on the enamel surface with respect to the adhesive and debonding instrument used
| Source of variance | Sum of square | Mean square | Df | F ratio | Significance |
| Adhesive type | 132.054 | 132.054 | 3 | 6.9 | 0.004 |
| Debonding instrument | 371.882 | 371.882 | 3 | 36.9 | 0.001 |
| Adhesive type × debonding instrument | 81.824 | 81.824 | 1 | 0.9 | 0.010 |
| Error | 804.738 | ||||
| Corrected total | 1423.379 |
Mean and standard deviation of adhesive remnants on the enamel and bracket surface among the four study groups
| Group | Mean ± SD | P-value | Mean ± SD | P-value | |
| Enamel | Bracket | ||||
| 1 | Transbond XT and LODI | 50.13±32.90 A | P<0.001** | 74.44±28.40 A | P<0.001** |
| 2 | Transbond XT and Dentaurum pliers | 53.85±31.74 A | 70.38±22.23 A | ||
| 3 | Unite and LODI | 53.43±39.30 A | 68.64±25.09 A | ||
| 4 | Unite and Dentaurum pliers | 28.76±26.22 B | 88.78±14.49 B | ||
| *p<.05; **p<.001 |
Frequency distribution of the Adhesive Remnant Index (ARI) scores and the chi-square comparison of the four study groups
| Test groups | ARI SCORE | |||||
| 0 | 1 | 2 | 3 | N | P-value | |
| Group 1 (Transbond XT & LODI) | 0 | 17 | 10 | 3 | 30 | 0.004 * |
| Group 2 (Transbond XT & Dentaurum) | 0 | 15 | 13 | 2 | 30 | |
| Group 3 Unite & LODI | 3 | 10 | 13 | 4 | 30 | |
| Group 4 Unite & Dentaurum | 1 | 26 | 2 | 1 | 30 | |
| ARI Score: 0, No adhesive left on the tooth surface; 1, Less than half of the adhesive left on the tooth surface ; 2, More than half of the adhesive left on tooth surface; 3, All adhesive left on the tooth surface |
Number and length of enamel cracks before and after debonding in each study group
| Groups | The number of cracks | The length of cracks | ||||
| Before bonding | After debonding | Before bonding | After debonding | |||
| Mean ± SD | P-value | Mean ± SD | P-value | |||
| 1 | 2.03±1.27 | 4.30±2.30 | <0.001** | 3.54±2.22 | 10.65±5.39 | <0.001** |
| 2 | 2.17±1.04 | 4.48±2.06 | <0.001** | 4.50±2.50 | 11.53±6.25 | <0.001** |
| 3 | 2.52±1.54 | 5.17±2.92 | <0.001** | 4.88±3.24 | 13.78±7.06 | <0.001** |
| 4 | 2.07±1.15 | 6.14±2.77 | <0.001** | 3.39±1.83 | 13.72±7.43 | <0.001** |
| *p<0.05;**p<0.001 |
The differences in the number and length of enamel cracks after debonding among the four groups using two-way analysis of variance (ANOVA) and post hoc Tukey’s multiple comparison tests
| Groups | The number of cracks | The length of cracks | ||
| Mean ± SD | P-value | Mean ± SD | P–value | |
| 1 | 2.27±1.87 A | <0.001** | 7.11±4.64 A | <0.001** |
| 2 | 2.31±1.83 A | 7.02±5.45 A | ||
| 3 | 2.65±2.39 A | 8.90±5.96 B | ||
| 4 | 4.07±2.50 B | 10.32±6.95 B | ||
| *p<0.05;**p<0.001 |