Literature DB >> 27132532

Leg length discrepancy in computer navigated total hip arthroplasty - how accurate are we?

Pregash Ellapparadja1, Vivek Mahajan1, Sami Atiya1, Biju Sankar1, Kamal Deep1.   

Abstract

INTRODUCTION: The success of total hip arthroplasty (THA) depends on the restoration of 2 important parameters - hip offset and leg length. Leg length discrepancy (LLD) after THA is associated with back pain, gait disorder, general patient dissatisfaction and aseptic loosening. Hence it is of utmost importance to minimise LLD.
METHODS: This is a retrospective study where we compared the reproduction of leg lengths between navigated THA group (152 patients) and nonnavigated THA group (57 patients). The leg lengths were measured radiologically using Ranawat technique on AP pelvic radiograph.
RESULTS: In the navigated group, the leg lengths of the reconstructed hips were restored to within 6 mm of the opposite leg in 146 patients (96.05%) while 6 patients (3.94%) had LLD of more than 6 mm. In the nonnavigated group, 29 patients (51%) had their leg lengths restored within 6 mm of the opposite leg while the remaining 28 patients (49%) had their LLD greater than 6 mm. Statistical analysis of the 2 pairs of LLD measurements (navigated hip and nonnavigated group) using Mann-Whitney U-test revealed significant difference between these two groups (p<0.001).
CONCLUSIONS: Based on our results we conclude that computer navigation is an excellent tool to facilitate the successful reproduction of leg length in THA.

Entities:  

Mesh:

Year:  2016        PMID: 27132532     DOI: 10.5301/hipint.5000368

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  10 in total

1.  The accuracy of component positioning during revision total hip arthroplasty using 3D optical computer-assisted navigation.

Authors:  Alex Tang; Vivek Singh; Mohamad Sharan; Mackenzie A Roof; John J Mercuri; Morteza Meftah; Ran Schwarzkopf
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-09-08

2.  Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study.

Authors:  Dong-Hui Guo; Xiao-Ming Li; Shi-Qiang Ma; Yun-Chao Zhao; Chao Qi; Yuan Xue
Journal:  Orthop Surg       Date:  2022-06-14       Impact factor: 2.279

3.  LIGAMENT PRESERVING TOTAL HIP ARTHROPLASTY PREVENTS DIFFERENT LEG LENGTH AND FEMORAL OFFSET.

Authors:  Masahiro Fujita; Shinya Hayashi; Tomoyuki Kamenaga; Takaaki Fujishiro; Tomoyuki Matsumoto; Ryosuke Kuroda
Journal:  Acta Ortop Bras       Date:  2022-07-06       Impact factor: 0.683

4.  Obesity does not influence acetabular component accuracy when using a 3D optical computer navigation system.

Authors:  Mohamad Sharan; Alex Tang; Lauren Schoof; Alexander Gaukhman; Morteza Meftah; Peter Sculco; Ran Schwarzkopf
Journal:  J Clin Orthop Trauma       Date:  2020-10-03

5.  Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

Authors:  D Hambright; M Hellman; R Barrack
Journal:  Bone Joint J       Date:  2018-01       Impact factor: 5.082

6.  Clinical efficacy of orthopilot navigation system versus conventional manual of total hip arthroplasty: A systematic review and meta-analysis.

Authors:  Jianguo Jia; Qun Zhao; Pei Lu; Guiyong Fan; Hao Chen; Chaoqun Liu; Jinlian Liu; Sheng Chen; Zhengshuai Jin
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

7.  Imageless navigation for primary total hip arthroplasty: a meta-analysis study.

Authors:  Filippo Migliorini; Francesco Cuozzo; Francesco Oliva; Joerg Eschweiler; Frank Hildebrand; Nicola Maffulli
Journal:  J Orthop Traumatol       Date:  2022-04-15

8.  Calculation method to predict postoperative limb length in patients undergoing THA following developmental dysplasia of hips.

Authors:  Renwen Guo; Jerry Yongqiang Chen; Guoqiang Zhang; Yonggang Zhou; Jiying Chen; Wei Chai
Journal:  BMC Musculoskelet Disord       Date:  2019-11-03       Impact factor: 2.362

9.  Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements.

Authors:  Shine Tone; Masahiro Hasegawa; Yohei Naito; Hiroki Wakabayashi; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2021-12-06       Impact factor: 2.362

10.  A low-volume surgeon is an independent risk factor for leg length discrepancy after primary total hip arthroplasty: a case-control study.

Authors:  Yuji Kishimoto; Hiroko Suda; Takahiro Kishi; Toshiaki Takahashi
Journal:  Int Orthop       Date:  2019-10-31       Impact factor: 3.075

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.