Literature DB >> 27127753

Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis.

Shabnam Ajami1, Ahmad Mina2, Seyed Amin Nabavizadeh3.   

Abstract

OBJECTIVES: To evaluate the effect of moments and the combination of forces and moments on the mechanical properties of a bracket type miniscrew, resembling engagement of a rectangular wire by three-dimensional (3D) finite element study.
MATERIALS AND METHODS: By solid work software (Dassaunlt systems solid works, concord, Mass), a 3D miniscrew model of 6, 8, 10 mm lengths was designed and inserted in the osseous block, consisted of the cortical, and cancellous bones. The stress distributions, maximum stresses, and deflections of the miniscrew were evaluated for all parts using ANSYS (Work Bench, 2014).
RESULTS: As the magnitudes of the load increased from 100 to 200, 400 and 800 grf-mm, the peak of stresses in the 6 mm long miniscrew were increased from 7.7 to 61.5 Mpa. The maximum values of Von Mises in the cancellous bone were tremendously lower in comparison to the cortical bone by one hundredth. As the length of the miniscrew in contact with the bone was increased, the amounts and patterns of stress distribution in the cortical bone and the miniscrew did not change significantly.
CONCLUSIONS: As the moment magnitude increased, the pick stresses increased linearly. The existence of cancellous bone was not significantly responsible for the stress distribution. The pattern of stress distribution did not change by the length of the miniscrew.

Entities:  

Keywords:  Finite element; force; miniscrew; moment; orthodontic

Year:  2016        PMID: 27127753      PMCID: PMC4830140          DOI: 10.4103/2278-0203.179416

Source DB:  PubMed          Journal:  J Orthod Sci        ISSN: 2278-0203


  14 in total

1.  Three-dimensional finite element analysis of strength, stability, and stress distribution in orthodontic anchorage: a conical, self-drilling miniscrew implant system.

Authors:  Shivani Singh; Subraya Mogra; V Surendra Shetty; Siddarth Shetty; Pramod Philip
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-03       Impact factor: 2.650

2.  Finite element analysis of miniscrew implants used for orthodontic anchorage.

Authors:  Te-Chun Liu; Chih-Han Chang; Tung-Yiu Wong; Jia-Kuang Liu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-04       Impact factor: 2.650

3.  Three-dimensional numerical simulation of dental implants as orthodontic anchorage.

Authors:  M M Gallas; M T Abeleira; J R Fernández; M Burguera
Journal:  Eur J Orthod       Date:  2005-02       Impact factor: 3.075

4.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Tohru Yoshida; Akiko Ono; Noriyoshi Shimizu
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

5.  Application of orthodontic mini-implants in adolescents.

Authors:  M Motoyoshi; M Matsuoka; N Shimizu
Journal:  Int J Oral Maxillofac Surg       Date:  2007-05-22       Impact factor: 2.789

6.  Numerical/experimental analysis of the stress field around miniscrews for orthodontic anchorage.

Authors:  A Gracco; A Cirignaco; M Cozzani; A Boccaccio; C Pappalettere; G Vitale
Journal:  Eur J Orthod       Date:  2008-12-15       Impact factor: 3.075

Review 7.  Mini-implants in orthodontics: a systematic review of the literature.

Authors:  Reint Reynders; Laura Ronchi; Shandra Bipat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-05       Impact factor: 2.650

8.  Forced eruption of palatally impacted canines using bracket-head miniscrews.

Authors:  Farzan Heravi; Hooman Shafaee; Ali Forouzanfar; Seyed Houssein Hoseini Zarch; Mohsen Merati
Journal:  J Clin Orthod       Date:  2014-09

9.  Miniscrews as orthodontic anchorage: a preliminary report.

Authors:  A Costa; M Raffainl; B Melsen
Journal:  Int J Adult Orthodon Orthognath Surg       Date:  1998

10.  Comparison of stability between cylindrical and conical type mini-implants. Mechanical and histological properties.

Authors:  Jong-Wan Kim; Seung-Hak Baek; Tae-Woo Kim; Young-Il Chang
Journal:  Angle Orthod       Date:  2008-07       Impact factor: 2.079

View more
  2 in total

1.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

2.  Effect of Different Surface Designs on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study.

Authors:  Jin-Young Choi; Jaehee Cho; Song Hee Oh; Seong-Hun Kim; Kyu-Rhim Chung; Gerald Nelson
Journal:  Sensors (Basel)       Date:  2021-03-11       Impact factor: 3.576

  2 in total