Literature DB >> 27066595

Real-time Data Acquisition and Maximum-Likelihood Estimation for Gamma Cameras.

L R Furenlid1, J Y Hesterman2, H H Barrett1.   

Abstract

We have developed modular gamma-ray cameras for biomedical imaging that acquire data with a raw list-mode acquisition architecture. All observations associated with a gamma-ray event, such as photomultiplier (PMT) signals and time, are assembled into an event packet and added to an ordered list of event entries that comprise the acquired data. In this work we present the design of the data-acquisition system, and discuss algorithms for a specialized computing engine to reside in the data path between the front and back ends of each camera and carry out maximum-likelihood position and energy estimations in real time while data was being acquired..

Keywords:  SPECT; data acquisition; gamma camera; gamma ray; maximum likelihood; position estimation

Year:  2005        PMID: 27066595      PMCID: PMC4824558          DOI: 10.1109/RTC.2005.1547506

Source DB:  PubMed          Journal:  IEEE NPSS Real Time Conf


  3 in total

1.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

2.  List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET.

Authors:  L Parra; H H Barrett
Journal:  IEEE Trans Med Imaging       Date:  1998-04       Impact factor: 10.048

3.  List-mode likelihood.

Authors:  H H Barrett; T White; L C Parra
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

  3 in total
  4 in total

1.  Maximum-likelihood methods in wavefront sensing: stochastic models and likelihood functions.

Authors:  Harrison H Barrett; Christopher Dainty; David Lara
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-02       Impact factor: 2.129

2.  Multiple-hit parameter estimation in monolithic detectors.

Authors:  William C J Hunter; Harrison H Barrett; Robert S Miyaoka; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

3.  Multiple-hit parameter estimation in monolithic detectors.

Authors:  William C J Hunter; Harrison H Barrett; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Med Imaging       Date:  2012-11-10       Impact factor: 10.048

4.  Towards continuous-to-continuous 3D imaging in the real world.

Authors:  L Caucci; Z Liu; A K Jha; H Han; L R Furenlid; H H Barrett
Journal:  Phys Med Biol       Date:  2019-09-18       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.