Literature DB >> 23193231

Multiple-hit parameter estimation in monolithic detectors.

William C J Hunter1, Harrison H Barrett, Tom K Lewellen, Robert S Miyaoka.   

Abstract

We examine a maximum-a-posteriori method for estimating the primary interaction position of gamma rays with multiple interaction sites (hits) in a monolithic detector. In assessing the performance of a multiple-hit estimator over that of a conventional one-hit estimator, we consider a few different detector and readout configurations of a 50-mm-wide square cerium-doped lutetium oxyorthosilicate block. For this study, we use simulated data from SCOUT, a Monte-Carlo tool for photon tracking and modeling scintillation- camera output. With this tool, we determine estimate bias and variance for a multiple-hit estimator and compare these with similar metrics for a one-hit maximum-likelihood estimator, which assumes full energy deposition in one hit. We also examine the effect of event filtering on these metrics; for this purpose, we use a likelihood threshold to reject signals that are not likely to have been produced under the assumed likelihood model. Depending on detector design, we observe a 1%-12% improvement of intrinsic resolution for a 1-or-2-hit estimator as compared with a 1-hit estimator. We also observe improved differentiation of photopeak events using a 1-or-2-hit estimator as compared with the 1-hit estimator; more than 6% of photopeak events that were rejected by likelihood filtering for the 1-hit estimator were accurately identified as photopeak events and positioned without loss of resolution by a 1-or-2-hit estimator; for PET, this equates to at least a 12% improvement in coincidence-detection efficiency with likelihood filtering applied.

Entities:  

Mesh:

Year:  2012        PMID: 23193231      PMCID: PMC3977801          DOI: 10.1109/TMI.2012.2226908

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Maximum Likelihood Event Estimation and List-mode Image Reconstruction on GPU Hardware.

Authors:  Luca Caucci; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

2.  SCOUT: A Fast Monte-Carlo Modeling Tool of Scintillation Camera Output.

Authors:  William C J Hunter; Harrison H Barrett; Thomas K Lewellen; Robert S Miyaoka; John P Muzi; Xiaoli Li; Wendy McDougald; Lawrence R Macdonald
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010

3.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

4.  Real-time Data Acquisition and Maximum-Likelihood Estimation for Gamma Cameras.

Authors:  L R Furenlid; J Y Hesterman; H H Barrett
Journal:  IEEE NPSS Real Time Conf       Date:  2005-06

5.  An electronically collimated gamma camera for single photon emission computed tomography. Part I: Theoretical considerations and design criteria.

Authors:  M Singh
Journal:  Med Phys       Date:  1983 Jul-Aug       Impact factor: 4.071

6.  Calibration Method for ML Estimation of 3D Interaction Position in a Thick Gamma-Ray Detector.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

7.  Bayesian reconstruction of photon interaction sequences for high-resolution PET detectors.

Authors:  Guillem Pratx; Craig S Levin
Journal:  Phys Med Biol       Date:  2009-08-04       Impact factor: 3.609

8.  Statistical LOR estimation for a high-resolution dMiCE PET detector.

Authors:  Kyle M Champley; Thomas K Lewellen; Lawrence R MacDonald; Robert S Miyaoka; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2009-10-07       Impact factor: 3.609

9.  Maximum-Likelihood Methods for Processing Signals From Gamma-Ray Detectors.

Authors:  Harrison H Barrett; William C J Hunter; Brian William Miller; Stephen K Moore; Yichun Chen; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

  9 in total
  1 in total

1.  Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs.

Authors:  Patrick Hallen; David Schug; Volkmar Schulz
Journal:  EJNMMI Phys       Date:  2020-02-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.