Literature DB >> 27056919

Analysis of radiation doses incurred during diagnostic cerebral angiography after the implementation of dose reduction strategies.

Tanja Schneider1,2, Emily Wyse2, Monica S Pearl2,3.   

Abstract

BACKGROUND: One goal of increasing awareness of radiation dose is to encourage personal and technical modifications in order to reduce the radiation exposure of patients and staff.
OBJECTIVE: To analyze the radiation doses incurred during diagnostic cerebral angiography and the angiographic techniques practiced over a 4-year period, in order to demonstrate the effectiveness of implementing radiation dose reduction strategies.
METHODS: A retrospective review of the first 50 consecutive adult and pediatric patients undergoing diagnostic cerebral angiography each year from 2010 to 2013 was performed. Angiograms and procedure examination protocols were reviewed for patient age, gender, diagnosis, angiography techniques, fluoroscopy time, reference point air kerma (Ka,r in mGy), and kerma-area product (PKA in μGym2).
RESULTS: From January 2010 to June 2013, a total of 231 diagnostic cerebral angiograms were reviewed (200 adults, 31 children). Adult patients were aged from 19 to 94 years and included 77 men and 123 women. Pediatric patients were aged from 2 to 18 years and comprised 11 boys and 20 girls. Median Ka,r and PKA significantly decreased from 2010 to 2013 in adults (1867 mGy; 21 231 µGym2 vs 653 mGy; 7860 µGym2) and children (644 mGy; 6495 µGym2 vs138 mGy; 1465 µGym2), (p<0.001).
CONCLUSIONS: Increased awareness and implementation of dose reduction strategies resulted in decreased radiation doses for diagnostic cerebral angiography both in adult and pediatric patients. The use of lower and variable digital subtraction angiography frame rates and tailored examinations contributed significantly to the reduced radiation doses observed during diagnostic cerebral angiography. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  Angiography; Technique

Mesh:

Year:  2016        PMID: 27056919     DOI: 10.1136/neurintsurg-2015-012204

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  9 in total

1.  Feasibility of ultra-low radiation dose digital subtraction angiography: Preliminary study in a simplified cerebral angiography phantom.

Authors:  Jun Young Maeng; Yunsun Song; Yu Sub Sung; Tae-Il Kim; Deok Hee Lee; Tae-Hyung Kim
Journal:  Interv Neuroradiol       Date:  2019-05-16       Impact factor: 1.610

2.  Image Quality of Low-Dose Cerebral Angiography and Effectiveness of Clinical Implementation on Diagnostic and Neurointerventional Procedures for Intracranial Aneurysms.

Authors:  J Choi; B Kim; Y Choi; N Y Shin; J Jang; H S Choi; S L Jung; K J Ahn
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-04       Impact factor: 3.825

3.  The Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study.

Authors:  T R Miller; J Zhuo; G Jindal; R Shivashankar; N Beaty; D Gandhi
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

4.  Removal of Antiscatter Grids for Spinal Digital Subtraction Angiography: Dose Reduction without Loss of Diagnostic Value.

Authors:  Emanuele Orrù; Amgad El Mekabaty; Diego San Millan; Monica S Pearl; Philippe Gailloud
Journal:  Radiology       Date:  2020-03-03       Impact factor: 11.105

5.  Determinants of Radiation Dose in Selective Ophthalmic Artery Chemosurgery for Retinoblastoma.

Authors:  A M Qureshi; L K Davies; P A Patel; A Rennie; F Robertson
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-14       Impact factor: 3.825

Review 6.  Radiation Exposure in Pediatric Interventional Procedures.

Authors:  Agapi Ploussi; Elias Brountzos; Spyridon Rammos; Sotiria Apostolopoulou; Efstathios P Efstathopoulos
Journal:  Cardiovasc Intervent Radiol       Date:  2021-05-19       Impact factor: 2.740

7.  Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose.

Authors:  Hee Jong Ki; Bum-Soo Kim; Jun-Ki Kim; Jai Ho Choi; Yong Sam Shin; Yangsean Choi; Na-Young Shin; Jinhee Jang; Kook-Jin Ahn
Journal:  Korean J Radiol       Date:  2022-01-04       Impact factor: 3.500

8.  Radiation Exposure during Neurointerventional Procedures in Modern Biplane Angiographic Systems: A Single-Site Experience.

Authors:  Ameer E Hassan; Sophie Amelot
Journal:  Interv Neurol       Date:  2017-02-11

9.  Radiation Dose Reduction without Compromise to Image Quality by Alterations of Filtration and Focal Spot Size in Cerebral Angiography.

Authors:  Dong Joon Kim; Min Keun Park; Da Eun Jung; Jung Han Kang; Byung Moon Kim
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500