Literature DB >> 27009758

Randomized comparison of long and short vascular sheaths in reduction of the operator radiation exposure during uterine artery embolization.

Meng-Qiu Cao1, Xue-Bin Zhang2, Zhi-Guo Zhuang1, Wei Zhou1, Jian-Rong Xu1, Yi-Cun Zhong3.   

Abstract

OBJECTIVE: To introduce a method in which a long sheath is used instead of the traditional short sheath, to reduce the radiation exposure of operators in uterine artery embolization (UAE).
METHODS: 52 patients undergoing UAE were randomly divided into two groups before the procedure: an 11-cm short sheath was used in Group A (n = 25), and a 45-cm-long sheath was used in Group B (n = 27); the 45-cm-long sheath was only partly inserted such that the hub of the sheath was approximately 34 cm caudal to the groin puncture site. All the procedures were standard bilateral UAE operations through unilateral approach. The other parameters of the two groups were kept the same, including the fluoroscopy conditions and the pelvic radiation field size. The thermoluminescent personal dosemeters were attached to the left wrist and left outer side of the thyroid collar of the operator during each operation. The radiation exposure of the operator, procedure duration and fluoroscopy time of each procedure were recorded. Statistical analysis was performed using independent samples t-test.
RESULTS: The radiation exposure of both the left hand and thyroid of the operator was significantly reduced with the long sheath compared with the short sheath (89.5 ± 7.2 μGy vs 186.7 ± 12.6 μGy, p < 0.001, and 54.1 ± 5.5 μGy vs 63.9 ± 7.4 μGy, p < 0.001, respectively). No significant differences were found in the procedure duration and fluoroscopy time between the two groups (p > 0.1).
CONCLUSION: Using a long sheath in UAE could significantly reduce the radiation exposure to the interventionists without extending the procedure duration or fluoroscopy time. ADVANCES IN KNOWLEDGE: For the first time, we introduce a simple and convenient method to reduce the radiation exposure of the operator in the UAE procedure.

Entities:  

Mesh:

Year:  2016        PMID: 27009758      PMCID: PMC5258135          DOI: 10.1259/bjr.20140448

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

1.  Uterine arteries: bilateral catheterization with a single femoral approach and a single 5-F catheter--technical note.

Authors:  J P Pelage; P Soyer; O Le Dref; H Dahan; J Coumbaras; M Kardache; R Rymer
Journal:  Radiology       Date:  1999-02       Impact factor: 11.105

2.  Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetry.

Authors:  C Koukorava; E Carinou; G Simantirakis; T G Vrachliotis; E Archontakis; C Tierris; P Dimitriou
Journal:  Radiat Prot Dosimetry       Date:  2010-11-02       Impact factor: 0.972

3.  Randomized comparison of operator radiation exposure during coronary angiography and intervention by radial or femoral approach.

Authors:  Helmut W Lange; Heiner von Boetticher
Journal:  Catheter Cardiovasc Interv       Date:  2006-01       Impact factor: 2.692

4.  Uterine artery embolization for emergent management of postpartum hemorrhage associated with placenta accreta.

Authors:  Hye Na Jung; Sung Wook Shin; Suk-Joo Choi; Sung Ki Cho; Kwang Bo Park; Hong Suk Park; Minho Kang; Sung Wook Choo; Young Soo Do; In-wook Choo
Journal:  Acta Radiol       Date:  2011-03-28       Impact factor: 1.990

5.  Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes.

Authors:  Camille Brasselet; Thierry Blanpain; Sophie Tassan-Mangina; Alain Deschildre; Sébastien Duval; Fabien Vitry; Nathalie Gaillot-Petit; Jean Paul Clément; Damien Metz
Journal:  Eur Heart J       Date:  2007-11-13       Impact factor: 29.983

6.  Impact of an extension tube on operator radiation exposure during coronary procedures performed through the radial approach.

Authors:  Nicolas Marque; Arnaud Jégou; Olivier Varenne; Emmanuel Salengro; Philippe Allouch; Olivier Margot; Christian Spaulding
Journal:  Arch Cardiovasc Dis       Date:  2009-11-14       Impact factor: 2.340

7.  Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments.

Authors:  Eliseo Vano; Norman J Kleiman; Ariel Duran; Mariana Romano-Miller; Madan M Rehani
Journal:  J Vasc Interv Radiol       Date:  2013-01-28       Impact factor: 3.464

8.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures.

Authors:  Koichi Chida; Haruo Saito; Hiroki Otani; Masahiro Kohzuki; Shoki Takahashi; Shogo Yamada; Kunio Shirato; Masayuki Zuguchi
Journal:  AJR Am J Roentgenol       Date:  2006-03       Impact factor: 3.959

9.  Uterine artery embolization for postpartum hemorrhage.

Authors:  Raúl Héctor Winograd
Journal:  Best Pract Res Clin Obstet Gynaecol       Date:  2008-09-14       Impact factor: 5.237

10.  Learning curve in the use of the radial artery as vascular access in the performance of percutaneous transluminal coronary angioplasty.

Authors:  S L Goldberg; R Renslo; R Sinow; W J French
Journal:  Cathet Cardiovasc Diagn       Date:  1998-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.