Literature DB >> 23369556

Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments.

Eliseo Vano1, Norman J Kleiman, Ariel Duran, Mariana Romano-Miller, Madan M Rehani.   

Abstract

PURPOSE: To estimate ocular radiation doses and prevalence of lens opacities in a group of interventional catheterization professionals and offer practical recommendations based on these findings to avoid future lens damage.
MATERIALS AND METHODS: Subjects included 58 physicians and 69 nurses and technicians attending an interventional cardiology congress and appropriate unexposed age-matched controls. Lens dose estimates were derived from combining experimental measurements in catheterization laboratories with questionnaire responses regarding workload, types of procedures, and use of eye protection. Lens opacities were observed by dilated slit lamp examination using indirect illumination and retroillumination. The frequency and severity of posterior lens changes were compared between the exposed and unexposed groups. The severity of posterior lens changes was correlated with cumulative eye dose.
RESULTS: Posterior subcapsular lens changes characteristic of ionizing radiation exposure were found in 50% of interventional cardiologists and 41% of nurses and technicians compared with findings of similar lens changes in<10% of controls. Estimated cumulative eye doses ranged from 0.1-18.9 Sv. Most lens injuries result after several years of work without eye protection.
CONCLUSIONS: A high prevalence of lens changes likely induced by radiation exposure in the study population suggests an urgent need for improved radiation safety and training, use of eye protection during catheterization procedures, and improved occupational dosimetry.
Copyright © 2013. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23369556     DOI: 10.1016/j.jvir.2012.10.016

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  37 in total

1.  Radiation exposure and safety practices during pediatric central line placement.

Authors:  Melody R Saeman; Lorrie S Burkhalter; Timothy J Blackburn; Joseph T Murphy
Journal:  J Pediatr Surg       Date:  2015-03-19       Impact factor: 2.545

2.  Hepatic radioembolization from transradial access: initial experience and comparison to transfemoral access.

Authors:  Bela Kis; Matthew Mills; Sarah E Hoffe
Journal:  Diagn Interv Radiol       Date:  2016 Sep-Oct       Impact factor: 2.630

3.  Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection.

Authors:  U O'Connor; C Walsh; A Gallagher; A Dowling; M Guiney; J M Ryan; N McEniff; G O'Reilly
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

4.  A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP.

Authors:  Thiruvengadam Muniraj; Harry R Aslanian; Loren Laine; James Farrell; Maria M Ciarleglio; Yanhong Deng; Henry Ho; Priya A Jamidar
Journal:  Am J Gastroenterol       Date:  2015-03-31       Impact factor: 10.864

Review 5.  Challenges in Occupational Dosimetry for Interventional Radiologists.

Authors:  E Vano; R Sanchez Casanueva; J M Fernandez Soto; G Bartal
Journal:  Cardiovasc Intervent Radiol       Date:  2021-01-03       Impact factor: 2.740

6.  Can image enhancement allow radiation dose to be reduced whilst maintaining the perceived diagnostic image quality required for coronary angiography?

Authors:  Anuja Joshi; Amber J Gislason-Lee; Claire Keeble; Uduvil M Sivananthan; Andrew G Davies
Journal:  Br J Radiol       Date:  2017-01-26       Impact factor: 3.039

7.  Randomized comparison of long and short vascular sheaths in reduction of the operator radiation exposure during uterine artery embolization.

Authors:  Meng-Qiu Cao; Xue-Bin Zhang; Zhi-Guo Zhuang; Wei Zhou; Jian-Rong Xu; Yi-Cun Zhong
Journal:  Br J Radiol       Date:  2016-03-24       Impact factor: 3.039

Review 8.  [Radiation protection in interventional radiology].

Authors:  R Adamus; R Loose; M Wucherer; M Uder; M Galster
Journal:  Radiologe       Date:  2016-03       Impact factor: 0.635

9.  How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

Authors:  Ah Na Kim; Young Jae Chang; Bo Kyung Cheon; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

10.  Impact of latest generation cardiac interventional X-ray equipment on patient image quality and radiation dose for trans-catheter aortic valve implantations.

Authors:  Amber J Gislason-Lee; Claire Keeble; Christoper J Malkin; Daniel Egleston; Josephine Bexon; Stephen M Kengyelics; Daniel Blackman; Andrew G Davies
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.