Literature DB >> 26997770

Tube Exposure Repair.

Stirbu Oana1, Jorge Vila2.   

Abstract

All across the world, glaucomatologists are adopting broader use of glaucoma drainage implants even as a primary surgical modality. To avoid tube exposure, which may predispose the eye to endophthalmitis, the implanted tube must be covered by a patch graft. However, these patch grafts also carry a high rate of progressive thinning and erosion, which is believed to result from the lack of cellular infiltration from the surrounding host conjunctival stroma and poor integration of these patch grafts to the host tissue. An ideal patch graft should offer good tensile strength, be suitable for tectonic support, and have biological activities to promote cellular infiltration by the surrounding host conjunctival stroma, thus reducing progressive allogeneic patch graft thinning/erosion. This review talks about various materials and modalities used for an exposed tube repair. How to cite this article: Oana S, Vila J. Tube Exposure Repair. J Current Glau Prac 2012;6(3):139-142.

Entities:  

Keywords:  Conjunctival erosion; Patch graft; Tube shunt.

Year:  2012        PMID: 26997770      PMCID: PMC4741121          DOI: 10.5005/jp-journals-10008-1121

Source DB:  PubMed          Journal:  J Curr Glaucoma Pract        ISSN: 0974-0333


  38 in total

1.  Late infectious endophthalmitis from exposed glaucoma setons.

Authors:  D B Krebs; J M Liebmann; R Ritch; M Speaker
Journal:  Arch Ophthalmol       Date:  1992-02

2.  Outcome of White pump shunt surgery for neovascular glaucoma in Asians.

Authors:  E Chihara; H Kubota; T Takanashi; N Nao-i
Journal:  Ophthalmic Surg       Date:  1992-10

3.  Use of amniotic membrane graft in glaucoma shunt surgery.

Authors:  Aashish Anand; Hosam Sheha; Christopher C Teng; Jeffrey M Liebmann; Robert Ritch; Celso Tello
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011 May-Jun

4.  A comparison of glaucoma drainage implant tube coverage.

Authors:  M Fran Smith; J William Doyle; John W Ticrney
Journal:  J Glaucoma       Date:  2002-04       Impact factor: 2.503

5.  Scleral patch grafts with Molteno setons.

Authors:  J Freedman
Journal:  Ophthalmic Surg       Date:  1987-07

6.  Fascia lata patch graft in glaucoma tube surgery.

Authors:  T M Tanji; D C Lundy; D S Minckler; D K Heuer; R Varma
Journal:  Ophthalmology       Date:  1996-08       Impact factor: 12.079

7.  Treatment outcomes in the Ahmed Baerveldt Comparison Study after 1 year of follow-up.

Authors:  Donald L Budenz; Keith Barton; William J Feuer; Joyce Schiffman; Vital P Costa; David G Godfrey; Yvonne M Buys
Journal:  Ophthalmology       Date:  2010-10-08       Impact factor: 12.079

8.  [Ahmed drainage device implant. Our experience between 1995 and 2003].

Authors:  F J Montañez; E Laso; M Suñer; C Amaya
Journal:  Arch Soc Esp Oftalmol       Date:  2005-04

9.  A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma.

Authors:  R S Ayyala; D Zurakowski; J A Smith; R Monshizadeh; P A Netland; D W Richards; W E Layden
Journal:  Ophthalmology       Date:  1998-10       Impact factor: 12.079

10.  Persistent leak after glaucoma aqueous shunt implantation.

Authors:  Marie-Claude Robert; Patrick Hamel; Pierre Blondeau; Mark R Lesk
Journal:  J Glaucoma       Date:  2013 Oct-Nov       Impact factor: 2.503

View more
  7 in total

1.  Comparison of complications after Ahmed versus Baerveldt implant in glaucoma patients: one year follow-up.

Authors:  Sara Listyani Koentjoro; Widya Artini; Iwan Soebijantoro; Vira Wardhana Istiantoro; Emma Rusmayani; Rini Sulastiwaty; Zeiras Eka Djamal; Arini Safira Nurul Akbar; Muhammad Yoserizal
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

2.  Tube Revision Outcomes for Exposure with Different Repair Techniques.

Authors:  Abeer Alawi; Ali AlBeshri; Konrad Schargel; Khabir Ahmad; Rizwan Malik
Journal:  Clin Ophthalmol       Date:  2020-10-02

3.  Patch Grafting Using an Ologen Collagen Matrix to Manage Tubal Exposure in Glaucoma Tube Shunt Surgery.

Authors:  Masaki Tanito; Ichiya Sano; Yoshifumi Ikeda; Etsuko Fujihara
Journal:  Case Rep Ophthalmol       Date:  2018-01-05

4.  Repair of Tube Erosion by Modifying the Tube Extender.

Authors:  Wendy W Liu; Astrid Werner; Teresa C Chen
Journal:  J Glaucoma       Date:  2020-07       Impact factor: 2.290

5.  Risk factors for exposure of Baerveldt glaucoma drainage implants: a case-control study.

Authors:  Ayaka Edo; Koji Jian; Yoshiaki Kiuchi
Journal:  BMC Ophthalmol       Date:  2020-09-10       Impact factor: 2.209

6.  Patch graft using collagen matrix (Ologen) for glaucoma drainage device exposure in a patient with Boston Keratoprosthesis type 1.

Authors:  Samir Jabbour; Mark R Lesk; Mona Harissi-Dagher
Journal:  Am J Ophthalmol Case Rep       Date:  2018-08-18

7.  A Novel Technique for Recurrent Tube Exposure Repair.

Authors:  J Minjy Kang; Yen Cheng Hsia; Ying Han
Journal:  Case Rep Ophthalmol Med       Date:  2020-03-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.