Literature DB >> 21563743

Use of amniotic membrane graft in glaucoma shunt surgery.

Aashish Anand1, Hosam Sheha, Christopher C Teng, Jeffrey M Liebmann, Robert Ritch, Celso Tello.   

Abstract

BACKGROUND AND
OBJECTIVE: To determine the safety and efficacy of amniotic membrane graft in glaucoma drainage device surgery. PATIENTS AND METHODS: Institutional retrospective case series of 44 patients undergoing glaucoma drainage device implantation with use of 300-μm thick amniotic membrane as a patch graft. Endpoints assessed were tube exposure, graft thinning, graft clarity, graft-related infection, and inflammation.
RESULTS: A total of 41 (93%) eyes had an uneventful course over a mean follow-up of 22 ± 3 months (range: 17 to 28 months). Tube exposure and hypotony each occurred in one eye and were successfully treated with a tube revision using double pericardial and amniotic membrane patch graft. The translucency of amniotic membrane graft enabled good visualization of the occluding suture when performing laser suture lysis in 16 eyes. Sequential anterior segment optical coherence tomography showed stable amniotic membrane graft thickness with a change from low to moderate reflectivity in the subconjunctival-graft bilayer.
CONCLUSION: Amniotic membrane graft offers good tectonic support and allows direct visualization of the underlying tube. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21563743     DOI: 10.3928/15428877-20110426-01

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  15 in total

1.  Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery.

Authors:  Regina A de Luna; Ameera Moledina; Jiangxia Wang; Henry D Jampel
Journal:  JAMA Ophthalmol       Date:  2017-09-01       Impact factor: 7.389

2.  Comparison of trabeculectomy and trabeculectomy with amniotic membrane transplantation in the same patient with bilateral glaucoma.

Authors:  Qing-Shan Ji; Bing Qi; Lian Liu; Wei Lao; Zhi-Hao Yang; Gui-Fang Wang; Guo-Cheng Yu; Jing-Xiang Zhong
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

Review 3.  Childhood glaucoma surgery in the 21st century.

Authors:  M Papadopoulos; B Edmunds; C Fenerty; P T Khaw
Journal:  Eye (Lond)       Date:  2014-06-13       Impact factor: 3.775

4.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

5.  Outcomes of the Shunt Tube Exposure Prevention Study: A Randomized Clinical Trial.

Authors:  Hosam Sheha; Celso Tello; Lama A Al-Aswad; Mohamed S Sayed; Richard K Lee
Journal:  Ophthalmol Glaucoma       Date:  2019-08-16

6.  The best thickness of cornea graft from SMILE surgery as patch graft in glaucoma drainage implant surgery.

Authors:  Yuhong Wang; Jinkun Liu; Weiyi Huang; Yazhang Xu; Meizhu Cheng; Zhengwei Shen
Journal:  Medicine (Baltimore)       Date:  2021-05-21       Impact factor: 1.817

7.  Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft).

Authors:  Feyzahan Ekici; Marlene R Moster; Victor Cvintal; Wanda D Hu; Michael Waisbourd
Journal:  Clin Ophthalmol       Date:  2015-05-04

8.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

9.  The use of collagen matrix (Ologen) as a patch graft in glaucoma tube shunt surgery, a retrospective chart review.

Authors:  John D Stephens; Steven R Sarkisian
Journal:  F1000Res       Date:  2016-08-01

10.  Short-Term Outcomes of KeraSys Patch Graft for Glaucoma Drainage Devices: A Case Series.

Authors:  Kundandeep S Nagi; Ricardo J Cumba; Nicholas P Bell; Lauren S Blieden; Alice Z Chuang; Kimberly A Mankiewicz; Donna Nguyen; Robert M Feldman
Journal:  J Ophthalmol       Date:  2013-03-17       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.