| Literature DB >> 18160495 |
S S Rajaratnam1, C Jack, A Tavakkolizadeh, M D George, R J Fletcher, M Hankins, J A N Shepperd.
Abstract
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0.68%) were lost to follow-up. With revision of the femoral component for any reason as the endpoint, the survival at a mean of 17 years was 97.4% (95% confidence interval 94.1 to 99.5), and with revision for aseptic loosening as the endpoint it was 100%. The survival at a maximum of 21 years with revision of the femoral component for any reason as the endpoint was 97.4% (95% confidence interval 81.0 or 99.5). These results compare favourably with the best long-term results of cemented or uncemented femoral components used in total hip replacement.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18160495 DOI: 10.1302/0301-620X.90B1.19731
Source DB: PubMed Journal: J Bone Joint Surg Br ISSN: 0301-620X