320 Slice CT in Imaging of Congenital Heart Diseases in Infants: A Single-Center Experience.

Gayathri Sreedher1, David Bruckman2, Shankar Srinivas Ganapathy1.   

Abstract

Objective The study was conducted to evaluate the best possible imaging technique for neonatal cardiac imaging including optimal injection techniques, intravenous line placement, expected radiation dose, and need for sedation while performing the study on a 320 slice Toshiba® Aquilion ONE® scanner. Study results can be used to optimize imaging parameters for maximum clinical yield. We provide representative images of our cases. Methodology Cardiac CTs performed on infants less than one year of age at the time of study were evaluated. Data collection included radiation dose, duration of the scan, heart rate, type and route of contrast injection, need for sedation or general anesthesia and quality of study including image contrast and motion artifacts. Results Average age of infants at the time of scan was approximately two months. Prospectively gated volumetric scans performed within one heartbeat with a single gantry turn formed the majority of studies. Average effective dose was below 1 mSv. Several patients were scanned without any sedation. Most studies were deemed diagnostic and of superior quality on a 4-point scale. Qualitative image analysis revealed an excellent intraclass correlation between two raters. Conclusion Parameters needed for successfully performing cardiac CTs with a high degree of diagnostic quality in neonates were identified. For infants below a year hand injection of Isovue 300 in a 24 G peripheral upper extremity IV line with real-time contrast bolus monitoring and manual start to scanning is adequate when being scanned on a 320 slice Volumetric scanner with prospective auto-target EKG gating. Sedation may not be necessary for infants when wrap and feed techniques and free breathing are employed. Radiation doses utilizing this technique were uniformly low.
Copyright © 2021, Sreedher et al.

Entities:  

Keywords:  infant cardiac imaging

Year:  2021        PMID: 33754089      PMCID: PMC7971719          DOI: 10.7759/cureus.13348

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  15 in total

1.  Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan.

Authors:  Hyun Woo Goo; Dong Hyun Yang
Journal:  Pediatr Radiol       Date:  2010-05-13

Review 2.  Role of CT in the evaluation of congenital cardiovascular disease in children.

Authors:  Jonathan R Dillman; Ramiro J Hernandez
Journal:  AJR Am J Roentgenol       Date:  2009-05       Impact factor: 3.959

3.  Non-sedated, free breathing cardiac CT for evaluation of complex congenital heart disease in neonates.

Authors:  B Kelly Han; David M Overman; Katharine Grant; Kristi Rosenthal; Stephanie Rutten-Ramos; David Cook; John R Lesser
Journal:  J Cardiovasc Comput Tomogr       Date:  2013-11-07

Review 4.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

5.  Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

Authors:  Peter K T Hui; Hyun Woo Goo; Jing Du; Janice J K Ip; Suzu Kanzaki; Young Jin Kim; Supika Kritsaneepaiboon; Oktavia Lilyasari; Suvipaporn Siripornpitak
Journal:  Pediatr Radiol       Date:  2017-04-24

6.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

7.  The analysis of ordinal agreement data: beyond weighted kappa.

Authors:  P Graham; R Jackson
Journal:  J Clin Epidemiol       Date:  1993-09       Impact factor: 6.437

8.  Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease.

Authors:  Faris Al-Mousily; Roger Y Shifrin; Frederick J Fricker; Nicholas Feranec; Nancy S Quinn; Arun Chandran
Journal:  Pediatr Cardiol       Date:  2011-01-06       Impact factor: 1.655

9.  Contrast medium application in pediatric high-pitch cardiovascular CT angiography: manual or power injection?

Authors:  Marc Saake; Michael M Lell; Oliver Rompel; Martin Gloeckler; Matthias May; Achim Eller; Stephan Achenbach; Michael Uder; Wolfgang Wuest
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-05-22

10.  Infant cardiac CT angiography with 64-slice and 256-slice CT: comparison of radiation dose and image quality using a pediatric phantom.

Authors:  Yi-Wei Lee; Ching-Ching Yang; Greta S P Mok; Tung-Hsin Wu
Journal:  PLoS One       Date:  2012-11-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.