Literature DB >> 26880499

A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.

Megan A Meislin1, Eric R Wagner1, Alexander Y Shin2.   

Abstract

PURPOSE: The purpose of this study was to validate elbow flexion and extension measured from smartphone photography obtained by participants and compared them with photographs obtained by surgeons and goniometric measurements.
METHODS: We enrolled 32 participants with a total of 64 elbows, aged 25 to 68 years. Participants obtained smartphone photographs of full elbow flexion and extension. Then surgeons obtained the same photographs and goniometric measurement of elbow range of motion (ROM). We measured ROM from the photographs using Adobe Photoshop and calculated average ROM. Comparisons of manual goniometer versus digital measurements, participant versus surgeon photograph measurements, and interobserver measurements were statistically analyzed.
RESULTS: Average ROM measured by manual goniometer and digital photographs was 0° to 129° (range, 0° to 140°) and 0° to 129° (range, 0° to 145°), respectively. The goniometer versus digital measurements interclass correlation was 0.828 (L) and 0.740 (R). Pearson coefficient was 0.845 (L) and 0.757 (R). Bland-Altman plots demonstrated that 30 of 32 digital measurements (L) and 31 of 32 measurements (R) were within the 95% confidence interval. Participant-obtained photographs compared with researcher's photographs interclass correlation was 0.955 (L) and 0.941 (R), with a Pearson coefficient of 0.962 (L) and 0.957 (R), respectively. Reviewing interobserver reliability, concordance coefficients were 0.793 (L) and 0.767 (R) and Pearson coefficients were 0.811 (L) and 0.780 (R). Bland-Altman plots demonstrated that 28 of 32 digital measurements (L) and 26 of 32 measurements (R) were within the 95% confidence interval.
CONCLUSIONS: Measuring elbow ROM using smartphone digital photography is valid and reliable. Participants were able to obtain accurate photographs and the measurements based on these photographs show no statistical difference from those taken by surgeons or goniometric measurement. CLINICAL RELEVANCE: This study validates using smartphone photography for measuring elbow ROM by laymen in a remote setting. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.
Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Digital photography; elbow range of motion; smartphone

Mesh:

Year:  2016        PMID: 26880499     DOI: 10.1016/j.jhsa.2016.01.006

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  13 in total

1.  The Application of Telemedicine in Upper Extremity Surgery.

Authors:  Dennis A DeBernardis; Michael Rivlin
Journal:  Arch Bone Jt Surg       Date:  2020-04

2.  Viability of Hand and Wrist Photogoniometry.

Authors:  Clifton G Meals; Rebecca J Saunders; Sameer Desale; Kenneth R Means
Journal:  Hand (N Y)       Date:  2017-04-09

3.  The smartphone inclinometer: A new tool to determine elbow range of motion?

Authors:  Frédéric Vauclair; Abdulaziz Aljurayyan; Fahad H Abduljabbar; Bardia Barimani; Patrick Goetti; Fiona Houghton; Edward J Harvey; Dominique M Rouleau
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-19

4.  Development of Joint Activity Angle Measurement and Cloud Data Storage System.

Authors:  Chiu-Ching Tuan; Yi-Chao Wu; Wen-Ling Yeh; Chun-Chieh Wang; Chi-Heng Lu; Shao-Wei Wang; Jack Yang; Tsair-Fwu Lee; Hsuan-Kai Kao
Journal:  Sensors (Basel)       Date:  2022-06-21       Impact factor: 3.847

5.  Smartphone "Selfies"-A reliable and accurate tool for measuring elbow range of motion.

Authors:  Maegan N Shields; Anthony M Vaichinger; Shawn W O'Driscoll
Journal:  Shoulder Elbow       Date:  2019-09-03

6.  Range of Motion Measurements of the Fingers Via Smartphone Photography.

Authors:  John Z Zhao; Philip E Blazar; Ariana N Mora; Brandon E Earp
Journal:  Hand (N Y)       Date:  2019-01-28

Review 7.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

Authors:  Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2018-06-03

8.  Adoption of Telemedicine: A Debrief for the Orthopedic Practitioner.

Authors:  Karim A Shafi; Katherine Fortson; Sravisht Iyer
Journal:  HSS J       Date:  2021-02-21

9.  RELIABILITY AND VALIDITY OF THE HALO DIGITAL GONIOMETER FOR SHOULDER RANGE OF MOTION IN HEALTHY SUBJECTS.

Authors:  Sarah Correll; Jennifer Field; Heather Hutchinson; Gabby Mickevicius; Amber Fitzsimmons; Betty Smoot
Journal:  Int J Sports Phys Ther       Date:  2018-08

10.  Validation of Teleconference-based Goniometry for Measuring Elbow Joint Range of Motion.

Authors:  Paul A Dent; Benjamin Wilke; Sarvram Terkonda; Ian Luther; Glenn G Shi
Journal:  Cureus       Date:  2020-02-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.