Literature DB >> 26842702

Evaluation of Performance Characteristics of the Aptima HIV-1 Quant Dx Assay for Detection and Quantitation of Human Immunodeficiency Virus Type 1 in Plasma and Cervicovaginal Lavage Samples.

Soya S Sam1, Jaclynn R Kurpewski2, Susan Cu-Uvin3, Angela M Caliendo3.   

Abstract

Quantification of HIV-1 RNA has become the standard of care in the clinical management of HIV-1-infected individuals. The objective of this study was to evaluate performance characteristics and relative workflow of the Aptima HIV-1 Quant Dx assay in comparison with the Abbott RealTime HIV-1 assay using plasma and cervicovaginal lavage (CVL) specimens. Assay performance was evaluated by using an AcroMetrix HIV-1 panel, AcroMetrix positive controls, Qnostics and SeraCare HIV-1 evaluation panels, 208 clinical plasma samples, and 205 matched CVL specimens on the Panther and m2000 platforms. The Aptima assay demonstrated good linearity over the quantification range tested (2 to 5 log10copies/ml), and there was strong linear correlation between the assays (R(2)= 0.99), with a comparable coefficient of variance of <5.5%. For the plasma samples, Deming regression analyses and Bland-Altman plots showed excellent agreement between the assays, with an interassay concordance of 91.35% (kappa = 0.75; 95% confidence interval [CI], 0.65 to 0.85), and on average, the viral loads determined by the Aptima assay were 0.21 log10copies/ml higher than those determined by the RealTime assay. The assays differed in their sensitivity for quantifying HIV-1 RNA loads in CVL samples, with the Aptima and RealTime assays detecting 30% and 20%, respectively. Aptima had fewer invalid results, and on average, the viral loads in CVL samples quantified by the Aptima assay were 0.072 log10copies/ml higher than those of the RealTime assay. Our results demonstrate that the Aptima assay is sensitive and accurate in quantifying viral loads in both plasma and CVL specimens and that the fully automated Panther system has all the necessary features suitable for clinical laboratories demanding high-throughput sample processing.
Copyright © 2016, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26842702      PMCID: PMC4809915          DOI: 10.1128/JCM.03289-15

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  23 in total

Review 1.  Validation of laboratory-developed molecular assays for infectious diseases.

Authors:  Eileen M Burd
Journal:  Clin Microbiol Rev       Date:  2010-07       Impact factor: 26.132

2.  Comparison of four commercial quantitative HIV-1 assays for viral load monitoring in clinical daily routine.

Authors:  Patrick Braun; Robert Ehret; Frank Wiesmann; Frauke Zabbai; Mechthild Knickmann; Rainer Kühn; Sven Thamm; Gerald Warnat; Heribert Knechten
Journal:  Clin Chem Lab Med       Date:  2007       Impact factor: 3.694

3.  Association between paired plasma and cervicovaginal lavage fluid HIV-1 RNA levels during 36 months.

Authors:  Susan Cu-Uvin; Brad Snyder; Joseph I Harwell; Joseph Hogan; Carla Chibwesha; Dawn Hanley; Jessica Ingersoll; Jaclynn Kurpewski; Kenneth H Mayer; Angela M Caliendo
Journal:  J Acquir Immune Defic Syndr       Date:  2006-08-15       Impact factor: 3.731

4.  Genital tract HIV-1 RNA shedding among women with below detectable plasma viral load.

Authors:  Susan Cu-Uvin; Allison K DeLong; Kartik K Venkatesh; Joseph W Hogan; Jessica Ingersoll; Jaclynn Kurpewski; Maria Pia De Pasquale; Richard D'Aquila; Angela M Caliendo
Journal:  AIDS       Date:  2010-10-23       Impact factor: 4.177

5.  Comparative evaluation of the Aptima HIV-1 Quant Dx assay and COBAS TaqMan HIV-1 v2.0 assay using the Roche High Pure System for the quantification of HIV-1 RNA in plasma.

Authors:  Gunnar Schalasta; Anna Börner; Andrea Speicher; Martin Enders
Journal:  Clin Chem Lab Med       Date:  2016-03       Impact factor: 3.694

6.  Real-time PCR quantification of genital shedding of herpes simplex virus (HSV) and human immunodeficiency virus (HIV) in women coinfected with HSV and HIV.

Authors:  Jérôme Legoff; Hicham Bouhlal; Gérard Grésenguet; Helen Weiss; Nzambi Khonde; Hakim Hocini; Nathalie Désiré; Ali Si-Mohamed; Jean de Dieu Longo; Cécile Chemin; Eric Frost; Jacques Pépin; Jean-Elie Malkin; Philippe Mayaud; Laurent Bélec
Journal:  J Clin Microbiol       Date:  2006-02       Impact factor: 5.948

7.  Cervical shedding of HIV-1 RNA among women with low levels of viremia while receiving highly active antiretroviral therapy.

Authors:  Michael N Neely; Lorie Benning; Jiaao Xu; Howard D Strickler; Ruth M Greenblatt; Howard Minkoff; Mary Young; James Bremer; Alexandra M Levine; Andrea Kovacs
Journal:  J Acquir Immune Defic Syndr       Date:  2007-01-01       Impact factor: 3.731

8.  Correlation of human immunodeficiency virus type 1 RNA levels in blood and the female genital tract.

Authors:  C E Hart; J L Lennox; M Pratt-Palmore; T C Wright; R F Schinazi; T Evans-Strickfaden; T J Bush; C Schnell; L J Conley; K A Clancy; T V Ellerbrock
Journal:  J Infect Dis       Date:  1999-04       Impact factor: 5.226

9.  Effect of treatment of asymptomatic bacterial vaginosis on HIV-1 shedding in the genital tract among women on antiretroviral therapy: a pilot study.

Authors:  Carla Moreira; Kartik K Venkatesh; Allison DeLong; Tao Liu; Jaclyn Kurpewski; Jessica Ingersoll; Angela M Caliendo; Susan Cu-Uvin
Journal:  Clin Infect Dis       Date:  2009-09-15       Impact factor: 9.079

10.  Comparison of the Abbott realtime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs.

Authors:  Cari R Sloma; Jeffrey J Germer; Tara M Gerads; Jayawant N Mandrekar; P Shawn Mitchell; Joseph D C Yao
Journal:  J Clin Microbiol       Date:  2009-02-04       Impact factor: 5.948

View more
  10 in total

1.  Evaluation of the Aptima HIV-1 Quant Dx Assay Using Plasma and Dried Blood Spots.

Authors:  Malaya K Sahoo; Vici Varghese; Elizabeth White; Meg Winslow; David A Katzenstein; Robert W Shafer; Benjamin A Pinsky
Journal:  J Clin Microbiol       Date:  2016-08-17       Impact factor: 5.948

2.  Brief Report: Relationship Between ABCC4 SNPs and Hepatitis B Virus Suppression During Tenofovir-Containing Antiretroviral Therapy in Patients With HIV/HBV Coinfection.

Authors:  Timothy Archampong; Oluwayemisi Ojewale; Kristi Bears; Yiqing Chen; Margaret Lartey; Kwamena W Sagoe; Adjoa Obo-Akwa; Yan Gong; Taimour Langaee; Awewura Kwara
Journal:  J Acquir Immune Defic Syndr       Date:  2019-12-01       Impact factor: 3.731

3.  Performance evaluation of the Aptima HIV-1 RNA Quant assay on the Panther system using the standard and dilution protocols.

Authors:  Rebecca Rossetti; Tara Smith; Wei Luo; Jennifer Taussig; Mariah Valentine-Graves; Patrick Sullivan; Jessica M Ingersoll; Colleen S Kraft; Steve Ethridge; Laura Wesolowski; Kevin P Delaney; S Michele Owen; Jeffrey A Johnson; Silvina Masciotra
Journal:  J Clin Virol       Date:  2020-06-01       Impact factor: 3.168

4.  Evaluation of Hologic Aptima HIV-1 Quant Dx Assay on the Panther System on HIV Subtypes.

Authors:  Mark M Manak; Holly R Hack; Sangeetha V Nair; Andrew Worlock; Jennifer A Malia; Sheila A Peel; Linda L Jagodzinski
Journal:  J Clin Microbiol       Date:  2016-08-10       Impact factor: 5.948

5.  Analytical characteristics and comparative evaluation of Aptima HIV-1 Quant Dx assay with Ampliprep/COBAS TaqMan HIV-1 test v2.0.

Authors:  Angelos Hatzakis; Helen Papachristou; Sangeetha J Nair; Jacqueline Fortunko; Tracy Foote; HeeCheol Kim; Tashi L Peling; Andrew J Worlock
Journal:  Virol J       Date:  2016-10-21       Impact factor: 4.099

6.  Multicenter Evaluation of Two Next-Generation HIV-1 Quantitation Assays, Aptima Quant Dx and Cobas 6800, in Comparison to the RealTime HIV-1 Reference Assay.

Authors:  Frank Wiesmann; Robert Ehret; Gudrun Naeth; Martin Däumer; Jörg Fuhrmann; Rolf Kaiser; Christian Noah; Martin Obermeier; Gunnar Schalasta; Carsten Tiemann; Eva Wolf; Heribert Knechten; Patrick Braun
Journal:  J Clin Microbiol       Date:  2018-09-25       Impact factor: 5.948

7.  Comparison of the Aptima HIV-1 Quant Dx assay with the COBAS AmpliPrep/COBAS TaqMan HIV-1 v2.0 Test for HIV-1 viral load quantification in plasma samples from HIV-1-infected patients.

Authors:  Serena Longo; Isabella Bon; Giuseppina Musumeci; Alessia Bertoldi; Vanessa D'Urbano; Leonardo Calza; Maria Carla Re
Journal:  Health Sci Rep       Date:  2018-03-13

8.  The Development of a Standardized Quality Assessment Material to Support Xpert® HIV-1 Viral Load Testing for ART Monitoring in South Africa.

Authors:  Lara Dominique Noble; Lesley Erica Scott; Asiashu Bongwe; Pedro Da Silva; Wendy Susan Stevens
Journal:  Diagnostics (Basel)       Date:  2021-01-22

9.  Prospective evaluation of accuracy of HIV viral load monitoring using the Aptima HIV Quant Dx assay with fingerstick and venous dried blood spots prepared under field conditions in Kenya.

Authors:  Matilu Mwau; Jeff Danda; Joseph Mbugua; Allan Handa; Jacqueline Fortunko; Andrew Worlock; Sangeetha Vijaysri Nair
Journal:  PLoS One       Date:  2021-04-02       Impact factor: 3.752

10.  Comparison of the performance of Aptima HIV-1 Quant Dx Assay with Abbott RealTime HIV Assay for viral load monitoring using plasma and Dried Blood Spots collected in Kenya.

Authors:  Matilu Mwau; Sven Schaffer; Humphrey Kimani; Purity Kasiano; Francis Ogolla; Elizabeth Ajema; Scriven Adoyo; Ednah Nyairo; Norah Saleri; Sangeetha Vijaysri Nair
Journal:  PLoS One       Date:  2022-08-22       Impact factor: 3.752

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.