Literature DB >> 17243923

Comparison of four commercial quantitative HIV-1 assays for viral load monitoring in clinical daily routine.

Patrick Braun1, Robert Ehret, Frank Wiesmann, Frauke Zabbai, Mechthild Knickmann, Rainer Kühn, Sven Thamm, Gerald Warnat, Heribert Knechten.   

Abstract

BACKGROUND: Quantification of viral load (VL) is standard for monitoring HIV-1 therapy and is crucial before deciding whether to switch or to continue a current antiretroviral regimen.
METHODS: We compared the performance of the four most widely used commercial viral-load assays, COBAS Amplicor Monitor v1.5, Versant HIV-1 RNA 3.0, Abbott RealTime HIV-1 and Cobas AmpliPrep/Cobas TaqMan HIV-1 (CAP/CTM), in terms of intra- and inter-assay variability, as well as hands-on-time, specificity and ability to quantify group M subtypes.
RESULTS: Although linearity and correlation were confirmed for the assays and comparable sensitivity and specificity were verified for genetically diverse HIV-1 subtypes, demonstrating suitability for monitoring of HIV group M isolates, the viral loads obtained showed variations, with a mean difference of 0.1-0.4 log, depending on the system used.
CONCLUSIONS: Although sensitivity and precision were confirmed for all the systems, differences between them should be taken into account when viral load monitoring of the same person is performed using different systems.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17243923     DOI: 10.1515/CCLM.2007.008

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  21 in total

1.  Comparison of HIV-1 viral load assay performance in immunological stable patients with low or undetectable viremia.

Authors:  Gudrun Naeth; Robert Ehret; Frank Wiesmann; Patrick Braun; Heribert Knechten; Annemarie Berger
Journal:  Med Microbiol Immunol       Date:  2012-06-15       Impact factor: 3.402

2.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

3.  Evaluation of the Abbott investigational use only realtime HIV-1 assay and comparison to the Roche Amplicor HIV-1 monitor test, version 1.5.

Authors:  Michael T Pyne; Eric Q Konnick; Amit Phansalkar; David R Hillyard
Journal:  J Mol Diagn       Date:  2009-05-21       Impact factor: 5.568

4.  Impact of discrepancies between the Abbott realtime and cobas TaqMan assays for quantification of human immunodeficiency virus type 1 group M non-B subtypes.

Authors:  M Wirden; R Tubiana; F Marguet; I Leroy; A Simon; M Bonmarchand; Z Ait-Arkoub; R Murphy; A G Marcelin; C Katlama; V Calvez
Journal:  J Clin Microbiol       Date:  2009-03-18       Impact factor: 5.948

5.  Evaluation of the Cavidi ExaVir Load assay (version 3) for plasma human immunodeficiency virus type 1 load monitoring.

Authors:  Vicki L Greengrass; Megan M Plate; Pauline M Steele; Justin T Denholm; Catherine L Cherry; Lisa M Morris; Anna Hearps; Suzanne M Crowe
Journal:  J Clin Microbiol       Date:  2009-07-15       Impact factor: 5.948

6.  Upgraded Cobas Ampliprep-Cobas TaqMan version 2.0 HIV-1 RNA quantification assay versus first version: correction of underestimations.

Authors:  M Wirden; R Tubiana; S Fourati; M Thevenin; A Simon; A Canestri; Z Ait-Arkoub; C Soulie; A G Marcelin; C Katlama; V Calvez
Journal:  J Clin Microbiol       Date:  2011-05-04       Impact factor: 5.948

7.  Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test and identification of rare polymorphisms potentially affecting assay performance.

Authors:  Michael T Pyne; Katherine L Brown; David R Hillyard
Journal:  J Clin Microbiol       Date:  2010-06-23       Impact factor: 5.948

8.  Evaluation of the Abbott investigational use only RealTime hepatitis C virus (HCV) assay and comparison to the Roche TaqMan HCV analyte-specific reagent assay.

Authors:  Michael T Pyne; Eric Q Konnick; Amit Phansalkar; David R Hillyard
Journal:  J Clin Microbiol       Date:  2009-07-22       Impact factor: 5.948

9.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

10.  Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Authors:  Africa Holguín; Marisa López; Mar Molinero; Vincent Soriano
Journal:  J Clin Microbiol       Date:  2008-07-02       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.