Ruo-Hui Zhang, Xiao-Mei Fan, Wen-Wen Bai, Yan-Kun Cao1.
Abstract
BACKGROUND: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer.Entities:
Mesh:
Year: 2016 PMID: 26831229 PMCID: PMC4799571 DOI: 10.4103/0366-6999.174500
Source DB: PubMed Journal: Chin Med J (Engl) ISSN: 0366-6999 Impact factor: 2.628
Dosimetric parameters comparison of CDR-CAS-IMAT and IMRT plans considering the target volume
| Plans | HI (PTV) | CI (PTV) | HI (CTV) | CI (CTV) | D95 (CTV) (cGy) | D98 (CTV) (cGy) | V98 (CTV) (%) | V100 (CTV) (%) |
|---|---|---|---|---|---|---|---|---|
| CDR-CAS-IMAT | 0.12 ± 0.02 | 0.85 ± 0.03 | 0.09 ± 0.02 | 0.46 ± 0.05 | 5196.33 ± 28.24 | 5153.40 ± 21.21 | 99.9 ± 0.13 | 5233.98 ± 34.32 |
| IMRT | 0.13 ± 0.02 | 0.81 ± 0.03 | 0.11 ± 0.02 | 0.43 ± 0.05 | 5162.63 ± 31.12 | 5093.54 ± 35.02 | 99.0 ± 0.59 | 5216.69 ± 31.81 |
| −1.35 | 3.87 | −3.20 | 4.23 | 4.68 | 7.80 | 6.04 | 2.15 | |
| 0.194 | 0.001 | 0.005 | 0.001 | 0.000 | 0.000 | 0.000 | 0.049 | |
Data are shown as mean ± SD. SD: Standard deviation; CDR-CAS-IMAT: Constant dose rate and constant angular spacing intensity-modulated arc therapy; IMRT: Intensity-modulated radiation therapy; PTV: Planning target volume; CTV: Clinical target volume; HI: Homogeneity index; CI: Conformity index; D95 is the minimum dose received by the 95% of the volume, D98, and so on; V98 is the volume of the target volume irradiated at 98% prescription dose, V100, and so on.
Dosimetric parameters comparison of CDR-CAS-IMAT and IMRT plans considering organs at risk
| Plans | Cord D2 (cGy) | Rectum V40 (%) | Bladder V50 (%) | Bowel V30 (%) |
|---|---|---|---|---|
| CDR-CAS-IMAT | 3743.8 ± 118.7 | 41.9 ± 6.1 | 17.4 ± 4.5 | 39.6 ± 6.5 |
| IMRT | 3806.2 ± 98.7 | 44.2 ± 4.8 | 16.6 ± 4.2 | 36.6 ± 7.5 |
| –2.70 | –2.50 | 2.20 | 3.00 | |
| 0.017 | 0.026 | 0.049 | 0.008 | |
Data are shown as mean ± SD. SD: Standard deviation; CDR-CAS-IMAT: Constant dose rate and constant angular spacing intensity-modulated arc therapy; IMRT: Intensity-modulated radiation therapy; D2 is the minimum dose received by 2% of the volume; V40 is the percentage of the dose equal to or more than 40 Gy volume to the total volume, V50, V30, and so on.
Figure 1Dose distributions in a transverse slice for constant dose rate and constant angular spacing intensity-modulated arc therapy and intensity-modulated radiation therapy plans of a case. The dose lines are depicted with a thick solid line: 56 Gy (red), 50.4 Gy (yellow), 48 Gy (orange), 45 Gy (green), 43 Gy (blue), and 40 Gy (dark blue).
Figure 2Dose volume histograms for the target volume and organs at risk for constant dose rate and constant angular spacing intensity-modulated arc therapy and intensity-modulated radiation therapy. Dose volume histograms for planning target volume, clinical target volume, and organs at risk for constant dose rate and constant angular spacing intensity-modulated arc therapy (solid line) and intensity-modulated radiation therapy (dashed line).
Dosimetric parameters comparison of CDR-CAS-IMAT and IMRT plans in healthy tissues (%)
| Plans | E-P (V5) | E-P (V10) | E-P (V15) | E-P (V20) | E-P (V50) |
|---|---|---|---|---|---|
| CDR-CAS-IMAT | 49.7 ± 9.6 | 42.0 ± 8.0 | 34.8 ± 6.7 | 27.2 ± 5.2 | 0.7 ± 0.2 |
| IMRT | 45.9 ± 9.1 | 37.6 ± 7.4 | 33.5 ± 6.5 | 26.7 ± 5.0 | 1.0 ± 0.3 |
| 16.40 | 21.20 | 6.50 | 2.0 | –3.80 | |
| 0.000 | 0.000 | 0.000 | 0.062 | 0.001 | |
Data are shown as mean ± SD. SD: Standard deviation; CDR-CAS-IMAT: Constant dose rate and constant angular spacing intensitymodulated arc therapy; IMRT: Intensity-modulated radiation therapy; E-P: The body volume minus the volume of planning target volume on computed tomography; V5 is the percentage of accepting dose equal to or more than 5 Gy volume to the total volume, V10, V15, V20, V50, and so on.