Literature DB >> 26810432

Tuning a High Transmission Ion Guide to Prevent Gas-Phase Proton Exchange During H/D Exchange MS Analysis.

Miklos Guttman1, Thomas E Wales2, Dale Whittington3, John R Engen2, Jeffery M Brown4, Kelly K Lee3.   

Abstract

Hydrogen/deuterium exchange (HDX) mass spectrometry (MS) for protein structural analysis has been adopted for many purposes, including biopharmaceutical development. One of the benefits of examining amide proton exchange by mass spectrometry is that it can readily resolve different exchange regimes, as evidenced by either binomial or bimodal isotope patterns. By careful analysis of the isotope pattern during exchange, more insight can be obtained on protein behavior in solution. However, one must be sure that any observed bimodal isotope patterns are not artifacts of analysis and are reflective of the true behavior in solution. Sample carryover and certain stationary phases are known as potential sources of bimodal artifacts. Here, we describe an additional undocumented source of deuterium loss resulting in artificial bimodal patterns for certain highly charged peptides. We demonstrate that this phenomenon is predominantly due to gas-phase proton exchange between peptides and bulk solvent within the initial stages of high-transmission conjoined ion guides. Minor adjustments of the ion guide settings, as reported here, eliminate the phenomenon without sacrificing signal intensity. Such gas-phase deuterium loss should be appreciated for all HDX-MS studies using such ion optics, even for routine studies not focused on interpreting bimodal spectra. Graphical Abstract ᅟ.

Entities:  

Keywords:  Bimodal; Binomial; Conjoined ion guide; Deuterium exchange; Deuterium loss; Envelope broadening; Gas-phase proton exchange; HDX; Intermolecular proton exchange; StepWave

Mesh:

Substances:

Year:  2016        PMID: 26810432      PMCID: PMC4829384          DOI: 10.1007/s13361-015-1330-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  24 in total

1.  Identification and characterization of EX1 kinetics in H/D exchange mass spectrometry by peak width analysis.

Authors:  David D Weis; Thomas E Wales; John R Engen; Matthew Hotchko; Lynn F Ten Eyck
Journal:  J Am Soc Mass Spectrom       Date:  2006-07-27       Impact factor: 3.109

2.  Semi-automated data processing of hydrogen exchange mass spectra using HX-Express.

Authors:  David D Weis; John R Engen; Ignatius J Kass
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-22       Impact factor: 3.109

3.  The utility of hydrogen/deuterium exchange mass spectrometry in biopharmaceutical comparability studies.

Authors:  Damian Houde; Steven A Berkowitz; John R Engen
Journal:  J Pharm Sci       Date:  2010-12-29       Impact factor: 3.534

Review 4.  Hydrogen exchange mass spectrometry: are we out of the quicksand?

Authors:  Roxana E Iacob; John R Engen
Journal:  J Am Soc Mass Spectrom       Date:  2012-04-03       Impact factor: 3.109

5.  False EX1 signatures caused by sample carryover during HX MS analyses.

Authors:  Jing Fang; Kasper D Rand; Penny J Beuning; John R Engen
Journal:  Int J Mass Spectrom       Date:  2011-04-30       Impact factor: 1.986

Review 6.  Hydrogen exchange mass spectrometry: what is it and what can it tell us?

Authors:  Sean R Marcsisin; John R Engen
Journal:  Anal Bioanal Chem       Date:  2010-03-01       Impact factor: 4.142

7.  Conformation and dynamics of biopharmaceuticals: transition of mass spectrometry-based tools from academe to industry.

Authors:  Igor A Kaltashov; Cedric E Bobst; Rinat R Abzalimov; Steven A Berkowitz; Damian Houde
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-29       Impact factor: 3.109

8.  Development of a peptide probe for the occurrence of hydrogen (1H/2H) scrambling upon gas-phase fragmentation.

Authors:  Kasper D Rand; Thomas J D Jørgensen
Journal:  Anal Chem       Date:  2007-10-13       Impact factor: 6.986

Review 9.  Applications of hydrogen/deuterium exchange MS from 2012 to 2014.

Authors:  Gregory F Pirrone; Roxana E Iacob; John R Engen
Journal:  Anal Chem       Date:  2014-11-14       Impact factor: 6.986

10.  CD4-induced activation in a soluble HIV-1 Env trimer.

Authors:  Miklos Guttman; Natalie K Garcia; Albert Cupo; Tsutomu Matsui; Jean-Philippe Julien; Rogier W Sanders; Ian A Wilson; John P Moore; Kelly K Lee
Journal:  Structure       Date:  2014-06-12       Impact factor: 5.006

View more
  15 in total

Review 1.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

2.  Changes in Structure and Antigenicity of HIV-1 Env Trimers Resulting from Removal of a Conserved CD4 Binding Site-Proximal Glycan.

Authors:  Yu Liang; Miklos Guttman; James A Williams; Hans Verkerke; Daniel Alvarado; Shiu-Lok Hu; Kelly K Lee
Journal:  J Virol       Date:  2016-09-29       Impact factor: 5.103

3.  Chasing Tails: Cathepsin-L Improves Structural Analysis of Histones by HX-MS.

Authors:  Malvina Papanastasiou; James Mullahoo; Katherine C DeRuff; Besnik Bajrami; Ioannis Karageorgos; Stephen E Johnston; Ryan Peckner; Samuel A Myers; Steven A Carr; Jacob D Jaffe
Journal:  Mol Cell Proteomics       Date:  2019-08-13       Impact factor: 5.911

4.  Studying Protein-DNA Interactions by Hydrogen/Deuterium Exchange Mass Spectrometry.

Authors:  Ruzena Filandrova; Daniel Kavan; Alan Kadek; Petr Novak; Petr Man
Journal:  Methods Mol Biol       Date:  2021

Review 5.  Advances in Hydrogen/Deuterium Exchange Mass Spectrometry and the Pursuit of Challenging Biological Systems.

Authors:  Ellie I James; Taylor A Murphree; Clint Vorauer; John R Engen; Miklos Guttman
Journal:  Chem Rev       Date:  2021-09-07       Impact factor: 72.087

6.  Mass Spectrometry Analysis of Dynamics and Interactions of the LPS Translocon LptDE.

Authors:  Francesco Fiorentino; Jani R Bolla
Journal:  Methods Mol Biol       Date:  2022

7.  Mass Spectral Detection of Forward- and Reverse-Hydrogen/Deuterium Exchange Resulting from Residual Solvent Vapors in Electrospray Sources.

Authors:  H Jamie Kim; O Tara Liyanage; Marina R Mulenos; Elyssia S Gallagher
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-11       Impact factor: 3.109

8.  Seven perspectives on GPCR H/D-exchange proteomics methods.

Authors:  Xi Zhang
Journal:  F1000Res       Date:  2017-01-30

9.  Structural monitoring of a transient intermediate in the hemagglutinin fusion machinery on influenza virions.

Authors:  M A Benhaim; V Mangala Prasad; N K Garcia; M Guttman; K K Lee
Journal:  Sci Adv       Date:  2020-04-29       Impact factor: 14.136

10.  Dynamics of an LPS translocon induced by substrate and an antimicrobial peptide.

Authors:  Francesco Fiorentino; Joshua B Sauer; Xingyu Qiu; Robin A Corey; C Keith Cassidy; Benjamin Mynors-Wallis; Shahid Mehmood; Jani R Bolla; Phillip J Stansfeld; Carol V Robinson
Journal:  Nat Chem Biol       Date:  2020-11-16       Impact factor: 15.040

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.