A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies.

S V Setlur Nagesh1, J Hinaman1, K Sommer1, Z Xiong1, C N Ionita1, D R Bednarek1, S Rudin1.   

Abstract

Modern 3D printing technology allows rapid prototyping of vascular phantoms based on an actual human patient with a high degree of precision. Using this technology, we present a platform to accurately simulate clinical views of neuro-endovascular interventions and devices. The neuro-endovascular interventional phantom has a 3D printed cerebrovasculature model derived from a patient CT angiogram and embedded inside a human skull providing bone attenuation. Acrylic layers were placed underneath and on top of the skull, simulating entrance and exit tissue attenuation and also simulating forward scatter. The 3D model was connected to a pulsatile flow loop for simulating interventions using clinical devices such as catheters and stents. To validate the x-ray attenuation and establish clinical accuracy, the automatic exposure selection by a clinical c-arm system for the phantom was compared with that for a commercial anthropomorphic head phantom (SK-150, Phantom Labs). The percentage difference between automatic exposure selection for the neuro-intervention phantom and the SK-150 phantom was under 10%. By changing 3D printed models, various patient diseased anatomies can be simulated accurately with the necessary x-ray attenuation. Using this platform various interventional procedures were performed using new imaging technologies such as a high-resolution x-ray fluoroscope and a dose-reduced region-of-interest attenuator and differential temporally filtered display for enhanced interventional imaging. Simulated clinical views from such phantom-based procedures were used to evaluate the potential clinical performance of such new technologies.

Entities:  

Year:  2018        PMID: 29887667      PMCID: PMC5990971          DOI: 10.1117/12.2293630

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  5 in total

1.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms.

Authors:  M Russ; R O'Hara; S V Setlur Nagesh; M Mokin; C Jimenez; A Siddiqui; D Bednarek; S Rudin; C Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-19

4.  A novel Region of Interest (ROI) imaging technique for biplane imaging in interventional suites: high-resolution small field-of-view imaging in the frontal plane and dose-reduced, large field-of-view standard-resolution imaging in the lateral plane.

Authors:  S N Swetadri Vasan; C Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

5.  Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.

Authors:  Ciprian N Ionita; Maxim Mokin; Nicole Varble; Daniel R Bednarek; Jianping Xiang; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.