Walter J Gomes1, João Carlos Leal2, Fabio Biscegli Jatene3, Nelson A Hossne1, Renata Gabaldi4, Glaucia Basso Frazzato4, Guilherme Agreli4, Domingo M Braile5. 1. Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil. 2. Sociedade Portuguesa de Beneficência de São José do Rio Preto, SP, Brazil. 3. Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil. 4. Braile Biomédica, São José do Rio Preto, SP, Brazil. 5. Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP, Brazil.
Abstract
INTRODUCTION: The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECTIVE: The objective of this study was to experimentally evaluate the implantation of a novel balloon-expandable aortic valve with sutureless bioprosthesis in sheep and report the early clinical application. METHODS: The bioprosthesis is made of a metal frame and bovine pericardium leaflets, encapsulated in a catheter. The animals underwent left thoracotomy and the cardiopulmonary bypass was established. The sutureless bioprosthesis was deployed to the aortic valve, with 1/3 of the structure on the left ventricular face. Cardiopulmonary bypass, aortic clamping and deployment times were recorded. Echocardiograms were performed before, during and after the surgery. The bioprosthesis was initially implanted in an 85 year-old patient with aortic stenosis and high risk for conventional surgery, EuroSCORE 40 and multiple comorbidities. RESULTS: The sutureless bioprosthesis was rapidly deployed (50-170 seconds; average=95 seconds). The aortic clamping time ranged from 6-10 minutes, average of 7 minutes; the mean cardiopulmonary bypass time was 71 minutes. Bioprostheses were properly positioned without perivalvar leak. In the first operated patient the aortic clamp time was 39 minutes and the patient had good postoperative course. CONCLUSION: The deployment of the sutureless bioprosthesis was safe and effective, thereby representing a new alternative to conventional surgery or transcatheter in moderate- to high-risk patients with severe aortic stenosis.
INTRODUCTION: The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECTIVE: The objective of this study was to experimentally evaluate the implantation of a novel balloon-expandable aortic valve with sutureless bioprosthesis in sheep and report the early clinical application. METHODS: The bioprosthesis is made of a metal frame and bovine pericardium leaflets, encapsulated in a catheter. The animals underwent left thoracotomy and the cardiopulmonary bypass was established. The sutureless bioprosthesis was deployed to the aortic valve, with 1/3 of the structure on the left ventricular face. Cardiopulmonary bypass, aortic clamping and deployment times were recorded. Echocardiograms were performed before, during and after the surgery. The bioprosthesis was initially implanted in an 85 year-old patient with aortic stenosis and high risk for conventional surgery, EuroSCORE 40 and multiple comorbidities. RESULTS: The sutureless bioprosthesis was rapidly deployed (50-170 seconds; average=95 seconds). The aortic clamping time ranged from 6-10 minutes, average of 7 minutes; the mean cardiopulmonary bypass time was 71 minutes. Bioprostheses were properly positioned without perivalvar leak. In the first operated patient the aortic clamp time was 39 minutes and the patient had good postoperative course. CONCLUSION: The deployment of the sutureless bioprosthesis was safe and effective, thereby representing a new alternative to conventional surgery or transcatheter in moderate- to high-risk patients with severe aortic stenosis.
Authors: Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon Journal: N Engl J Med Date: 2012-03-26 Impact factor: 91.245
Authors: Samir R Kapadia; Martin B Leon; Raj R Makkar; E Murat Tuzcu; Lars G Svensson; Susheel Kodali; John G Webb; Michael J Mack; Pamela S Douglas; Vinod H Thourani; Vasilis C Babaliaros; Howard C Herrmann; Wilson Y Szeto; Augusto D Pichard; Mathew R Williams; Gregory P Fontana; D Craig Miller; William N Anderson; Jodi J Akin; Michael J Davidson; Craig R Smith Journal: Lancet Date: 2015-03-15 Impact factor: 79.321
Authors: Thierry A Folliguet; François Laborde; Konstantinos Zannis; Gabriel Ghorayeb; Axel Haverich; Malakh Shrestha Journal: Ann Thorac Surg Date: 2012-05 Impact factor: 4.330
Authors: Amine Mazine; Kevin Teoh; Ismail Bouhout; Gopal Bhatnagar; Marc Pelletier; Pierre Voisine; Philippe Demers; Michel Carrier; Denis Bouchard Journal: Can J Cardiol Date: 2014-10-31 Impact factor: 5.223
Authors: Giuseppe Santarpino; Steffen Pfeiffer; Joachim Sirch; Ferdinand Vogt; Giovanni Concistrè; Theodor Fischlein Journal: J Cardiovasc Med (Hagerstown) Date: 2014-03 Impact factor: 2.160