Literature DB >> 26728514

Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?

Weixiong Liao1, Hao Zhang1, Zhongli Li2, Ji Li1.   

Abstract

BACKGROUND: Arthroscopic double-row suture-anchor fixation and open reduction and internal fixation (ORIF) are used to treat displaced greater tuberosity fractures, but there are few data that can help guide the surgeon in choosing between these approaches. QUESTIONS/PURPOSES: We therefore asked: (1) Is there a difference in surgical time between arthroscopic double-row suture anchor fixation and ORIF for isolated displaced greater tuberosity fractures? (2) Are there differences in the postoperative ROM and functional scores between arthroscopic double-row suture anchor fixation and ORIF for isolated displaced greater tuberosity fractures? (3) Are there differences in complications resulting in additional operations between the two approaches?
METHODS: Between 2006 and 2012, we treated 79 patients surgically for displaced greater tuberosity fractures. Of those, 32 (41%) were considered eligible for our study based on inclusion criteria for isolated displaced greater tuberosity fractures with a displacement of at least 5 mm but less than 2 cm. During that time, we generally treated patients with displaced greater tuberosity fractures with a displacement greater than 1 cm or with a fragment size greater than 3×3 cm with open treatment, and patients with displaced greater tuberosity fractures with a displacement less than 1 cm or with a fragment size less than 3×3 cm with arthroscopic treatment. Fifty-three underwent open treatment based on those indications, and 26 underwent arthroscopic treatment, of whom 17 (32%) and 15 (58%) were available for followup at a mean of 34 months (range, 24-28 months). All patients with such fractures identified from our institutional database were treated by these two approaches and no other methods were used. Surgical time was defined as the time from initiation of the incision to the time when suture of the incision was finished, and was determined by an observer with a stopwatch. Patients were followed up in the outpatient department at 6, 12, and 24 weeks, and every 6 month thereafter. Radiographs showed optimal reduction immediately after surgery and at every followup. Radiographs were obtained to assess fracture healing. Patients were followed up for a mean of 34 months (range, 24-48 months). At the last followup, ROM, VAS score, and American Shoulder and Elbow Surgeons (ASES) score were used to evaluate clinical outcomes. All these data were retrieved from our institutional database through chart review. Complications were assessed through chart review by one observer other than the operating surgeon.
RESULTS: Patients who underwent arthroscopic double-row suture anchor fixation had longer surgical times than did patients who underwent ORIF (mean, 95.3 minutes, SD, 10.6 minutes vs mean, 61.5 minutes, SD, 7.2 minutes; mean difference, 33.9 minutes; 95% CI, 27.4-40.3 minutes; p < 0.001). All patients achieved bone union within 3 months. Compared with patients who had ORIF, the patients who had arthroscopic double-row suture anchor fixation had greater ranges of forward flexion (mean, 152.7°, SD, 13.3° vs mean, 137.7°, SD, 19.2°; p = 0.017) and abduction (mean, 146.0°, SD, 16.4° vs mean, 132.4°, SD, 20.5°; p = 0.048), and higher ASES score (mean, 91.8 points, SD, 4.1 points vs mean, 87.4 points, SD, 5.8 points; p = 0.021); however, in general, these differences were small and of questionable clinical importance. With the numbers available, there were no differences in the proportion of patients experiencing complications resulting in reoperation; secondary subacromial impingement occurred in two patients in the ORIF group and postoperative stiffness in one from the ORIF group. The two patients experiencing secondary subacromial impingement underwent reoperation to remove the implant. The patient with postoperative stiffness underwent adhesion release while receiving anesthesia, to improve the function of the shoulder. These three patients had the only reoperations.
CONCLUSIONS: We found that in the hands of surgeons comfortable with both approaches, there were few important differences between arthroscopic double-row suture anchor fixation and ORIF for isolated displaced greater tuberosity fractures. Future, larger studies with consistent indications should be performed to compare these treatments; our data can help inform sample-size calculations for such studies. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Year:  2016        PMID: 26728514      PMCID: PMC4814441          DOI: 10.1007/s11999-015-4663-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

Review 1.  Measures of adult shoulder function: Disabilities of the Arm, Shoulder, and Hand Questionnaire (DASH) and its short version (QuickDASH), Shoulder Pain and Disability Index (SPADI), American Shoulder and Elbow Surgeons (ASES) Society standardized shoulder assessment form, Constant (Murley) Score (CS), Simple Shoulder Test (SST), Oxford Shoulder Score (OSS), Shoulder Disability Questionnaire (SDQ), and Western Ontario Shoulder Instability Index (WOSI).

Authors:  Felix Angst; Hans-Kaspar Schwyzer; André Aeschlimann; Beat R Simmen; Jörg Goldhahn
Journal:  Arthritis Care Res (Hoboken)       Date:  2011-11       Impact factor: 4.794

2.  Surgical treatment of comminuted, displaced fractures of the greater tuberosity of the proximal humerus: a new technique of double-row suture-anchor fixation and long-term results.

Authors:  Deepak N Bhatia; Karin S van Rooyen; D F du Toit; Joe F de Beer
Journal:  Injury       Date:  2006-08-24       Impact factor: 2.586

Review 3.  Percutaneous fixation of proximal humeral fractures.

Authors:  D Herscovici; D T Saunders; M P Johnson; R Sanders; T DiPasquale
Journal:  Clin Orthop Relat Res       Date:  2000-06       Impact factor: 4.176

4.  Anterior traumatic shoulder dislocation associated with displaced greater tuberosity fracture: the necessity of operative treatment.

Authors:  Panayiotis Dimakopoulos; Andreas Panagopoulos; George Kasimatis; Spiros A Syggelos; Elias Lambiris
Journal:  J Orthop Trauma       Date:  2007-02       Impact factor: 2.512

5.  Arthroscopic treatment for greater tuberosity fractures: rationale and surgical technique.

Authors:  Ettore Taverna; Valerio Sansone; Ferdinando Battistella
Journal:  Arthroscopy       Date:  2004-07       Impact factor: 4.772

6.  Displaced fractures of the greater tuberosity: a comparison of operative and nonoperative treatment.

Authors:  Patrick Platzer; Gerhild Thalhammer; Gerhard Oberleitner; Florian Kutscha-Lissberg; Thomas Wieland; Vilmos Vecsei; Christian Gaebler
Journal:  J Trauma       Date:  2008-10

7.  Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures.

Authors:  Jong-Hun Ji; Weon-Yoo Kim; Ki-Hang Ra
Journal:  Arthroscopy       Date:  2007-03-23       Impact factor: 4.772

8.  Open reduction and internal fixation of two-part displaced fractures of the greater tuberosity of the proximal part of the humerus.

Authors:  E L Flatow; F Cuomo; M G Maday; S R Miller; S J McIlveen; L U Bigliani
Journal:  J Bone Joint Surg Am       Date:  1991-09       Impact factor: 5.284

9.  Mechanism of injury and morphology of the greater tuberosity fracture.

Authors:  Christian Bahrs; Erich Lingenfelter; Franziska Fischer; Eduard M Walters; Michael Schnabel
Journal:  J Shoulder Elbow Surg       Date:  2006 Mar-Apr       Impact factor: 3.019

Review 10.  Isolated tuberosity fractures of the proximal humeral: current concepts.

Authors:  Konrad I Gruson; David E Ruchelsman; Nirmal C Tejwani
Journal:  Injury       Date:  2008-03       Impact factor: 2.586

View more
  14 in total

1.  Arthroscopic Treatment of Greater Tuberosity Avulsion Fractures.

Authors:  Jonathan A Godin; J Christoph Katthagen; Erik M Fritz; Jonas Pogorzelski; Peter J Millett
Journal:  Arthrosc Tech       Date:  2017-06-12

2.  Arthroscopic reduction and fixation of greater tuberosity fractures of the humerus.

Authors:  Zinon T Kokkalis; Efstratios Papanikos; Ekaterini Bavelou; Georgios Togias; Spyridon Sioutis; Andreas F Mavrogenis; Andreas Panagopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-01-02

3.  Titanium mini locking plate with trans-osseous sutures for the treatment of humeral greater tuberosity fracture osteosynthesis versus PHILOS: a retrospective view.

Authors:  Gang Xue; Kapil Chahal; Thou Lim; Siyuan Hu; Shaohua Li; Jie Liu
Journal:  Int Orthop       Date:  2018-03-03       Impact factor: 3.075

Review 4.  Surgical fixation of isolated greater tuberosity fractures of the humerus- systematic review and meta-analysis.

Authors:  Sachin Kumar; Arya Mishra; Hemant Singh; David Clark; Marius Espag; Amol Tambe
Journal:  J Clin Orthop Trauma       Date:  2021-10-27

5.  Isolated greater tuberosity fractures of the proximal humerus: anatomy, injury patterns, multimodality imaging, and approach to management.

Authors:  Eric A White; Matthew R Skalski; Dakshesh B Patel; Jordan S Gross; Anderanik Tomasian; Nathanael Heckmann; George R Matcuk
Journal:  Emerg Radiol       Date:  2018-02-16

Review 6.  [Posttraumatic and postoperative shoulder stiffness : Trauma, rotator cuff reconstruction, instability operations and shoulder arthroplasty].

Authors:  Felix Toft; Fabrizio Moro; Markus Scheibel
Journal:  Unfallchirurg       Date:  2019-12       Impact factor: 1.000

7.  [Effectiveness of open reduction and locking compression hook plate in treatment of isolated humeral greater tuberosity fractures].

Authors:  Cheng Long; Zhou Xiang; Gang Zhong; Shiqiang Cen; Song Kuang; Changchun He; Tao Jiang; Fuguo Huang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-04-15

8.  Arthroscopic Fixation for Tibial Eminence Fractures: Comparison of Double-Row and Transosseous Anchor Knot Fixation Techniques with Suture Anchors.

Authors:  Ji Li; Chuihui Liu; Zhongli Li; Yangmu Fu; Yimeng Yang; Qiang Zhang
Journal:  Med Sci Monit       Date:  2018-10-15

9.  Arthroscopic treatment of isolated subscapularis avulsion fracture: a case report and literature review.

Authors:  Jiebo Chen; Caiqi Xu; Jinzhong Zhao
Journal:  JSES Int       Date:  2020-02-21

10.  Short-term reoperation risk after surgical and nonsurgical management of isolated greater tuberosity fractures.

Authors:  Akshar H Patel; Olivia C Lee; Michael J O'Brien; Felix H Savoie; William F Sherman
Journal:  JSES Int       Date:  2021-02-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.