Literature DB >> 15241328

Arthroscopic treatment for greater tuberosity fractures: rationale and surgical technique.

Ettore Taverna1, Valerio Sansone, Ferdinando Battistella.   

Abstract

A description of a new technique for arthroscopic treatment of minimally displaced greater tuberosity fractures of the humerus and associated soft tissue lesions is presented. This kind of fracture is usually treated nonsurgically. However, recent evidence suggests that even a small amount of superior displacement may produce shoulder dysfunction and require a perfect surgical reduction and fixation. Moreover, any displaced fracture of the greater tuberosity presents a high rate of associated and largely undetected soft tissue lesions. To avoid underestimating accompanying soft tissue pathology, arthroscopic assessment before open treatment of greater tuberosity fractures has been suggested. In 2 earlier case reports, we described the use of an arthroscope not only to diagnose and treat a rotator cuff tear and a Bankart lesion associated with a minimally displaced greater tuberosity fracture but also to arthroscopically reduce and treat the fracture. With advancements in arthroscopy and equipment, we refined and systematized the original arthroscopic technique that we have routinely used since 1997. This article presents the new technique.

Entities:  

Mesh:

Year:  2004        PMID: 15241328     DOI: 10.1016/j.arthro.2004.04.072

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  16 in total

1.  [Bony avulsions of the rotator cuff : Arthroscopic concepts].

Authors:  S Greiner; M Scheibel
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

Review 2.  [Rotator cuff avulsion fractures. Current concepts in the surgical treatment].

Authors:  S Pauly; M Scheibel
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

3.  Arthroscopic refixation of a combined fracture of the greater and lesser tuberosity of the proximal humerus.

Authors:  S Pauly; S Herrmann; C Perka; S Greiner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-12       Impact factor: 4.342

4.  [Associated injuries with greater tuberosity fractures : Mechanism of injury, diagnostics, treatment].

Authors:  M Muhm; S Arend; H Winkler; T Ruffing
Journal:  Unfallchirurg       Date:  2017-10       Impact factor: 1.000

Review 5.  [Arthroscopic fracture treatment of the shoulder joint].

Authors:  C Gerhardt; L J Lehmann
Journal:  Orthopade       Date:  2018-02       Impact factor: 1.087

6.  [Innovations and prognoses].

Authors:  C Voigt; H Lill
Journal:  Unfallchirurg       Date:  2011-12       Impact factor: 1.000

7.  Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?

Authors:  Weixiong Liao; Hao Zhang; Zhongli Li; Ji Li
Journal:  Clin Orthop Relat Res       Date:  2016-01-04       Impact factor: 4.176

8.  Simultaneous arthroscopic treatment of displaced greater tuberosity and glenoid fracture using a double-row technique.

Authors:  Nicolas Pujol; Olivier Fong; Stephane Scharycki; Julien Remi; Philippe Beaufils; Philippe Boisrenoult
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

9.  Arthroscopic-assisted plate fixation for displaced large-sized comminuted greater tuberosity fractures of proximal humerus: a novel surgical technique.

Authors:  Sang-Eun Park; Jae-Jung Jeong; Karnav Panchal; Jong-Yun Lee; Hyung-Ki Min; Jong-Hun Ji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-29       Impact factor: 4.342

10.  The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures.

Authors:  Ali Maqdes; Bruno Levy; Shahnaz Klouche; Philippe Hardy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-09       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.