Literature DB >> 17916486

Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures.

Jong-Hun Ji1, Weon-Yoo Kim, Ki-Hang Ra.   

Abstract

In cases of displaced greater tuberosity fractures, treatments by arthroscopic-assisted reduction and percutaneous screw fixation have been reported. However, in cases in which there is a comminuted fracture or a minimally displaced fracture combined with concomitant lesions such as rotator cuff tear or labral pathology, it is difficult to reduce the fracture and to treat other pathologies by use of a percutaneous screw. Recently, many surgeons have used the double-row repair method in rotator cuff repair, which provides a tendon-bone interface better suited for biologic healing and restoring normal anatomy. In accordance with this method, we used the arthroscopic technique of double-row suture anchor fixation for a minimally displaced greater tuberosity fracture without additional incision. Initially, debridement was performed on the fracture surface by use of a shaver, and the medial-row anchor was inserted through the anterior portal or the intact cuff. Two lateral-row anchors were inserted just anterior and posterior to the lower margin of the fractured fragment under C-arm guidance. The medial-row sutures and lateral-row sutures were then placed. Arthroscopic double-row suture anchor fixation of a displaced greater tuberosity fracture restores the original footprint of the rotator cuff and normal tendon-bone interface of the displaced greater tuberosity fracture.

Entities:  

Mesh:

Year:  2007        PMID: 17916486     DOI: 10.1016/j.arthro.2006.11.029

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  17 in total

1.  Arthroscopic fixation of displaced greater tuberosity fracture of the proximal humerus.

Authors:  Sang-Uk Lee; Changhoon Jeong; Il-Jung Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

2.  [Bony avulsions of the rotator cuff : Arthroscopic concepts].

Authors:  S Greiner; M Scheibel
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

Review 3.  [Rotator cuff avulsion fractures. Current concepts in the surgical treatment].

Authors:  S Pauly; M Scheibel
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

4.  A new procedure for tibial spine avulsion fracture fixation.

Authors:  Matthew A Mann; Nicholas M Desy; Paul A Martineau
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-24       Impact factor: 4.342

5.  Arthroscopic reduction and fixation for displaced greater tuberosity fractures using the modified suture-bridge technique.

Authors:  RenLong Li; Ming Cai; Kun Tao
Journal:  Int Orthop       Date:  2017-04-11       Impact factor: 3.075

6.  Arthroscopic refixation of a combined fracture of the greater and lesser tuberosity of the proximal humerus.

Authors:  S Pauly; S Herrmann; C Perka; S Greiner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-12       Impact factor: 4.342

7.  [Associated injuries with greater tuberosity fractures : Mechanism of injury, diagnostics, treatment].

Authors:  M Muhm; S Arend; H Winkler; T Ruffing
Journal:  Unfallchirurg       Date:  2017-10       Impact factor: 1.000

8.  A new "double-pulley" dual-row technique for arthroscopic fixation of bony Bankart lesion.

Authors:  Jin Zhang; Chunyan Jiang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

Review 9.  [Arthroscopic fracture treatment of the shoulder joint].

Authors:  C Gerhardt; L J Lehmann
Journal:  Orthopade       Date:  2018-02       Impact factor: 1.087

10.  Simultaneous arthroscopic treatment of displaced greater tuberosity and glenoid fracture using a double-row technique.

Authors:  Nicolas Pujol; Olivier Fong; Stephane Scharycki; Julien Remi; Philippe Beaufils; Philippe Boisrenoult
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.