Literature DB >> 21782090

Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

Antonio Benito1, Guillermo M Pérez, Sandra Mirabet, Meritxell Vilaseca, Jaume Pujol, José M Marín, Pablo Artal.   

Abstract

PURPOSE: To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument.
SETTING: Hospital Universitario Virgen de la Arrixaca, Murcia, Spain.
DESIGN: Evaluation of diagnostic test or technology.
METHODS: Dynamic recording of double-pass retinal images during unforced tear-film breakup was performed in eyes with mild dry-eye symptoms (study group) and in an asymptomatic control group. Series of consecutive retinal images were recorded every 0.5 seconds while the patient avoided blinking. Measurements were performed under low-light conditions to naturally increase pupil diameter and maximize the method's sensitivity. Additional clinical tests were performed for comparison and included tear breakup time (TBUT), Schirmer I tests, and a normalized questionnaire (McMonnies). From the retinal images, a quality metric, the intensity distribution index, was calculated. An objective TBUT value was estimated in each eye when the intensity distribution index surpassed a defined threshold value compared with the initial baseline.
RESULTS: The study group comprised 20 eyes and the control group, 18 eyes. Symptomatic dry eyes had a typical exponential increase in the intensity distribution index with time. The objective TBUT values in the study group were comparable to the clinical TBUT estimates.
CONCLUSIONS: The new objective optical method to evaluate the quality and stability of the tear film was sensitive in detecting mild symptoms of dry eye and differentiating from normal cases. The procedure may allow early detection and follow-up of patients' tear film-related complaints.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21782090     DOI: 10.1016/j.jcrs.2011.03.036

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  24 in total

1.  Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.

Authors:  Ai-Lian Hu; Li-Ya Qiao; Ye Zhang; Xiao-Gu Cai; Lei Li; Xiu-Hua Wan
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

Review 2.  TFOS DEWS II Tear Film Report.

Authors:  Mark D P Willcox; Pablo Argüeso; Georgi A Georgiev; Juha M Holopainen; Gordon W Laurie; Tom J Millar; Eric B Papas; Jannick P Rolland; Tannin A Schmidt; Ulrike Stahl; Tatiana Suarez; Lakshman N Subbaraman; Omür Ö Uçakhan; Lyndon Jones
Journal:  Ocul Surf       Date:  2017-07-20       Impact factor: 5.033

3.  Quantifying intraocular scatter with near diffraction-limited double-pass point spread function.

Authors:  Junlei Zhao; Fei Xiao; Jian Kang; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

4.  Evaluation of dry eye signs and symptoms in patients with systemic sclerosis.

Authors:  Beatriz de A F Gomes; Marcony R Santhiago; Mário N L de Azevedo; Haroldo V Moraes
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-18       Impact factor: 3.117

5.  Optical quality of toric intraocular lens implantation in cataract surgery.

Authors:  Xian-Wen Xiao; Jing Hao; Hong Zhang; Fang Tian
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Evaluations of wavefront aberrations and corneal surface regularity in dry eye patients measured with OPD Scan III.

Authors:  Rong-Jun Liu; Bai-Kai Ma; Yu-Fei Gao; Yi-Yun Liu; Hong Qi
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

7.  Scale and spatial distribution of aberrations associated with tear breakup.

Authors:  Nikole L Himebaugh; Jayoung Nam; Arthur Bradley; Haixia Liu; Larry N Thibos; Carolyn G Begley
Journal:  Optom Vis Sci       Date:  2012-11       Impact factor: 1.973

8.  Impact of scatter on double-pass image quality and contrast sensitivity measured with a single instrument.

Authors:  Juan M Bueno; Guillermo Pérez; Antonio Benito; Pablo Artal
Journal:  Biomed Opt Express       Date:  2015-11-13       Impact factor: 3.732

9.  Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes.

Authors:  Hun Lee; Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

10.  Longitudinal assessment of optical quality and intraocular scattering using the double-pass instrument in normal eyes and eyes with short tear breakup time.

Authors:  Hidenaga Kobashi; Kazutaka Kamiya; Kyohei Yanome; Akihito Igarashi; Kimiya Shimizu
Journal:  PLoS One       Date:  2013-12-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.