Literature DB >> 26692401

Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy.

Steven Kim1, James Heller, Zohora Iqbal, Rishi Kant, Eun Jung Kim, Jeremy Durack, Maythem Saeed, Loi Do, Steven Hetts, Mark Wilson, Paul Brakeman, William H Fissell, Shuvo Roy.   

Abstract

Silicon nanopore membranes (SNMs) with compact geometry and uniform pore size distribution have demonstrated a remarkable capacity for hemofiltration. These advantages could potentially be used for hemodialysis. Here, we present an initial evaluation of the SNM's mechanical robustness, diffusive clearance, and hemocompatibility in a parallel plate configuration. Mechanical robustness of the SNM was demonstrated by exposing membranes to high flows (200 ml/min) and pressures (1,448 mm Hg). Diffusive clearance was performed in an albumin solution and whole blood with blood and dialysate flow rates of 25 ml/min. Hemocompatibility was evaluated using scanning electron microscopy and immunohistochemistry after 4 hours in an extracorporeal porcine model. The pressure drop across the flow cell was 4.6 mm Hg at 200 ml/min. Mechanical testing showed that SNM could withstand up to 775.7 mm Hg without fracture. Urea clearance did not show an appreciable decline in blood versus albumin solution. Extracorporeal studies showed blood was successfully driven via the arterial-venous pressure differential without thrombus formation. Bare silicon showed increased cell adhesion with a 4.1-fold increase and 1.8-fold increase over polyethylene glycol (PEG)-coated surfaces for tissue plasminogen factor (t-PA) and platelet adhesion (CD41), respectively. These initial results warrant further design and development of a fully scaled SNM-based parallel plate dialyzer for renal replacement therapy.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26692401      PMCID: PMC4777646          DOI: 10.1097/MAT.0000000000000311

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  17 in total

Review 1.  Hemodialyzer membranes and configurations: a historical perspective.

Authors:  W R Clark
Journal:  Semin Dial       Date:  2000 Sep-Oct       Impact factor: 3.455

2.  Biocompatibility of the dialysis membrane.

Authors:  Yoshiaki Takemoto; Toshihidei Naganuma; Rikio Yoshimura
Journal:  Contrib Nephrol       Date:  2010-10-07       Impact factor: 1.580

Review 3.  Hemodialysis effect on platelet count and function and hemodialysis-associated thrombocytopenia.

Authors:  John T Daugirdas; Angelito A Bernardo
Journal:  Kidney Int       Date:  2012-05-16       Impact factor: 10.612

Review 4.  Ultrathin silicon membranes for wearable dialysis.

Authors:  Dean G Johnson; Tejas S Khire; Yekaterina L Lyubarskaya; Karl J P Smith; Jon-Paul S Desormeaux; Jeremy G Taylor; Thomas R Gaborski; Alexander A Shestopalov; Christopher C Striemer; James L McGrath
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

Review 5.  History of hemodialyzers' designs.

Authors:  Zbylut J Twardowski
Journal:  Hemodial Int       Date:  2008-04       Impact factor: 1.812

6.  Clinical implications of fluid mechanics in parallel flow plate diayzers.

Authors:  R B Freeman; G Roushey; V Hegadus; R C Pabico; R Cestero
Journal:  Clin Nephrol       Date:  1974       Impact factor: 0.975

7.  NIH Image to ImageJ: 25 years of image analysis.

Authors:  Caroline A Schneider; Wayne S Rasband; Kevin W Eliceiri
Journal:  Nat Methods       Date:  2012-07       Impact factor: 28.547

8.  In vitro clearance and hemocompatibility assessment of ultrathin nanoporous silicon membranes for hemodialysis applications using human whole blood.

Authors:  Morteza Ahmadi; Maud Gorbet; John T W Yeow
Journal:  Blood Purif       Date:  2013-07-31       Impact factor: 2.614

9.  Biomolecular transport through hemofiltration membranes.

Authors:  A T Conlisk; Subhra Datta; William H Fissell; Shuvo Roy
Journal:  Ann Biomed Eng       Date:  2009-01-30       Impact factor: 3.934

10.  Imaging assessment of a portable hemodialysis device: detection of possible failure modes and monitoring of functional performance.

Authors:  Olufoladare G Olorunsola; Steven H Kim; Ryan Chang; Yuo-Chen Kuo; Steven W Hetts; Alex Heller; Rishi Kant; Maythem Saeed; William H Fissell; Shuvo Roy; Mark W Wilson
Journal:  Med Instrum (Luton)       Date:  2014-03-27
View more
  2 in total

1.  Silicon Micropore-Based Parallel Plate Membrane Oxygenator.

Authors:  Ajay Dharia; Emily Abada; Benjamin Feinberg; Torin Yeager; Willieford Moses; Jaehyun Park; Charles Blaha; Nathan Wright; Benjamin Padilla; Shuvo Roy
Journal:  Artif Organs       Date:  2017-08-11       Impact factor: 3.094

Review 2.  Ambulatory Hemodialysis-Technology Landscape and Potential for Patient-Centered Treatment.

Authors:  Nina Hojs; William H Fissell; Shuvo Roy
Journal:  Clin J Am Soc Nephrol       Date:  2019-11-14       Impact factor: 8.237

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.